Customer:
Bernard from Bay shore, NY
Parts Used:
WR24X10156, WR24X10155
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Freezer door would open when food door would close
Bought two gaskets for both doors was just going to replace both due to age. Food door gasket was received damaged shipped poorly and I am still waiting on a refund. But went ahead with the repair , since freezer door was the one I was concerned about. Opened Freezer door gasket package and it was dirty and looked old from sitting in warehouse. I had to but it in the tub to make it pliable and I cleaned it also since it was in water already. Installed it pretty simple . Turned out the refrigerator wasn't leveled properly. Didn't realize the refrigerator is suppose to slope to the back . Called up GE and they helped me out. Customer Service from partselect.com and GE were very nice.
19 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mike from Aguilar, CO
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from bensalem, PA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry from Daly City, CA
Parts Used:
WR50X10068, WR51X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Freezer thaws on top, no fan running in freezer
REPLACING THE DEFROST HEATER & BRA:
1- Empty freezer.
2- Remove all shelves.
3- Remove white painted metal wall plate opposite
the freezer door. There are 2 phillips head screws
attaching it.
4- There may be ice build-up on the freezer coils,
thaw the ice using a hair dryer.
5- Remove the 2 phillips screws holding the
defrost heater to the freezer coil frame, at the
bottom of the frame.
6- Install the defrost heater to the frame.
7- Replace metal panel.

REPLACING THE DEFROST THERMOSTAT.

1-Perform steps 1-4 above.
2-Locate the thermostat at the top of the freezer
coil in the freezer.
3-Cut the wires connecting the thermostat.
4-Connect the new thermostat to the wires that
were connecting the old thermostat, connecting
the wire color to the same color wire.

Note: Connect the wires by using wire splices
available at radio shack. Use splices
sized for 20 guage wire, and wrap with
electrical tape to protect from moisture.

5- Replace metal panel.
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
EDWARD from INDIAN WELLS, CA
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Fresh food section lights were all out, but the bulbs tested good elsewhere.
I popped the switch out using the blade of a small screwdriver and noticed that it connected with two wires via a slide on connector for each one. I noted the info on the old switch to identify which wire went to which terminal. I held each wire with a pair of pliers while I pulled the wire connector off the terminal on the old switch. I connected the two wires to the correct terminals on the new swith, and popped the switch back into the door frame. Easy, easy, easy and saved the $40 service call + parts cost!
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Boca Raton, FL
Parts Used:
WR55X10942C
Difficulty Level:
Difficult
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Ice Dispenser not working
As it turned out much of the electronics is driven by 13.5 volts off the Main Control Board. The Ice Dispenser caused the problem because it over currented the depleted board power. You could hear a clicking noise from the board which was the main relay short cycling and not staying energized. While waiting for the replacement board I unpluged the condenser fan which is a DC motor and uses the Board power. In place of that fan I use a small table top fan to keep the condenser cool. As it turned out I only needed it for 3 days because Parts Select did a super quick job of delivering the new board. Thanks for the super service!!!!!! Removal of the board only required unpluging the electrical connections squezing the retaining board pins with pliers and pulling the board out, pushing on the new board and connecting the electrical plugs. If the board locks like mine did, just unplug the main board power plug, let the memory clear and replug the power plug. The unit should then start and run with no problems.
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GEORGE from ELIOT, ME
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Will not make ice
Bing , Bang, Boom.
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Perkasie, PA
Parts Used:
WR51X10055
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Fridge not cold
On this fridge, you MUST take out the ice maker. First took out the shelves. Then take out the ice maker. This is done by taking out the four screws on the side that hold the assembly containing the bulb. Then there is one screw that holds that assembly to the icemaker. Do not take out any other screws, this is a mistake I made that cost me a few more hours figuring out how to get the other parts to mount correctly to the assembly containing the bulb. The icemaker should lift right out once the white plus is unplugged from the assembly that holds the light. Then took out the shelf brackets and finally could remove rear panel. Found it all iced up as others have. Took 1.5 hours to manually defrost while using sponges to sop up all the water that would run into the drain if you let it. Was about a gallon of water so using sponges worked well. Heater was open when checked with a meter, but you could tell it was blown by the way it looked. All cloudy. Put things back in reverse order. Had an issue with the icemaker shooting water out and missing the icemaker. Eventually was able to align better. This fridge had also just stopped dispensing water. I think the lines may have been frozen in the back, because one day after defrosting manually, the water dispenser started working again Overall this took about 4 hours. But a few days later, the water dispenser again stopped working. Not sure about that one. I have a valve already that I will try for this issue but somehow I don't think its the valve.
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jose from La Vernia, TX
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
Water dispenser would not shut off when you released it. It would spill water and run for ten or twelve seconds after removing glass and releasing dispenser.
Ordered the new part (water valve). Took off the bad one followed directions on you video. The video explained the process making it easy to do.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Raymond, NE
Parts Used:
WR57X33326
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice maker making no ice
I first replaced in-line water filter to the fridge. No ice. Then I replaced the water filter inside the fridge. Still no ice. I inspected the water inlet feeding the ice cube trays and it was froze up with ice. I removed the two screws holding the ice maker in place to remove the ice from the inlet tray. I then used a hair dryer to melt the ice accumulated in the in-coming water tube. Turned off the water and unplugged the fridge. When replacing the old water valve, I first blew through the hose feeding the ice maker to be sure that it was clear of ice. After re-attaching the water hoses and the electrical connections, I turned on the water, plugged in the fridge and turned the ice maker switch back on. Next morning I had ice cubes. Only mystery is I am not hearing the usual water noise when water is feeding the cube tray like I did before, - not to worry though if it works. My drawer is now full of cubes.
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
chris from GROVE CITY, OH
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
The eavporator coils were completely frozen which prevented fridge-freezer air circulation
1. Removed all food, shelves, and ice bin from freezer compartment.
2. Removed freezer light hood and unscrewed freezer bulb.
3. Removed rear evaporator cover panel (2 Phillip’s screws, 2 hex screws).
4. Melted ice on coils with hair blow dryer (needed bath towels to collected water).
5. Removed old defrost heater (2 Phillips screws, 2 plug-ins).
6. New heater connected without any adjustments.
7. Replaced evaporator cover ice bin, shelves and food.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
inessa from manalapan, NJ
Parts Used:
WR23X21444
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
frezer door light switch broke (I have 2 boys :)
The repaire guy came in tooke it out and told me it is goin to coast $20 for the part and $50 for the labor..... So I looked, It was soooo eeezzz ALL you have to do is get the switch out( with help of my butter knife :) it plugs in to a little outlet on the wire (on the botom side) so take out the old one and plug in the new one wich I got for $8 + $6 shipping = $15 THANK YOU PART SELECT for saving me $55 Im a 36 y/o stayathome mom and Ihave never don this before, Im very proud of my self. well... it was very easy!
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
josephine from rochester, NY
Parts Used:
WR50X10068, WR55X10025, WR51X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
coil would freeze up about every 2-3 weeks
took back panel off in freezer.unpluged unit then cut wire to sensor tie in new one wire nut them up and taped.on the heater strip took off two screws and unpluged two wires put the new in same way as taking old one off.I am pleased that the parts from part select came as fast as they did I would for sure buy from them again and prices were very fair.Thank you very much for your service.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from HENDERSON, CO
Parts Used:
WR50X10068, WR51X10055
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Wrench set
Evaporate coils freezing up-refrigerator/freezer warm
Level of difficulty, as far a mechanical skill goes is relatively easy; however, everything in the interior of the freezer (including icemaker) must be removed to get to the defrost thermostat. The defrost heater only needs the racks and back panel removed. It probably took about 45 minutes with a heat gun to melt the ice off of the coils so that I could work on it-need lots of towels/rags to pick up the water.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
M &M Aviation from ESCANABA, MI
Parts Used:
WR55X10025, WR02X10668, WR02X10647
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator side freezing food
Replaced both temp sensors worked good for 2 days then began freezing food. Looked into it further on line. Found small motorized door broken that controls the cold air from the freezer
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PSI23NCPACC