Alan from Ruther Glen, VA
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench set
My water hose broke, the valve is 1 use.
1. remove back shield of fridge.
2. unscrew old valve.
3. remove electrical connections.
4. remove white inserts on new valve.
5. cut feed hoses next to old valve.
6. place white inserts on hoses.
7 insert hoses into recepticals on new valve.
8 shut off water supply to fridge.
9. remove water suply line from old valve.
10. attach water supply line to new valve.
11. connect electrical connections.
12. bolt valve back on to fridge
13. turn on water supply to fridge
14. test both ice maker and water dispensor
15. replace back shield to fridge
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randy from VALLEY CENTER, CA
Parts Used:
WR02X12008
Difficulty Level:
Very Difficult
Total Repair Time:
More than 2 hours
Loud whirling noises when the motor started up, then they subside (and stop) in a short time
I have not yet done the repair. After watching this repair video two problems came to mind. First I only ordered one grommet not knowing that there were two (or more I don't yet know). The second problem is that this video must be for a fridge from like the 1940, but it looks NOTHING like mine from 2008. The manual shows a bazillion parts and frankly I'm just a wee bit afraid to get started, and I am generally very handy, buuuttttttttt I don't know about this one
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Deborah from BRADLEYVILLE, MO
Parts Used:
WR23X37285
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Broken light switch
This was so easy I think it took me 2 minutes. I am not very mechanically inclined but that didn't matter! Works perfect thank you!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Irmo, SC
Parts Used:
WR57X33326
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
No water to dispenser or ice maker.
Replacement valve fit perfectly but didn't fix the problem. More troubleshooting found blockage through the water filter assy although I don't use a filter and just have the the bypass plug installed...7 years like this. Used compressed air to blow out the line and got some crud out. Works now but can't turn water pressure up full or line hammers and stops flow. Left supply valve open slightly which supplies ice maker fine and dispenser ok. Must be something wrong with internal spring stopper in filter assy...keeps water from pouring out if filter or bypass not installed.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Brentwood, CA
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
My son's Refrigerator
I started out replacing a bad thermostat, no problem,
when I hooked up the water, I found that the water resovior had a leak.
I replaced the resovior, easy fix, but I had to buy two 5/16 brass couplers.
then I found that the box would not get below 10 degrees, and the suction pressure was very low.
I figured that the fan motor was burned out, so I opened up the access covers, the fan motor was hanging there with broken mounts, so I replaced the motor, and repaired the mount.
Everything works great now, The parts shiping was very fast, I was impressed.
I thought I was going to get away without fixing everyones
HVAC problems when I retired.
Friends and family still remember that you are the HVAC man.
Tom
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Glenn from Pembroke, NH
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
Water running out of ice cube maker
After turning the water off, I removed the silver covering located on the left side bottom. The valve was connected to the frame on the left side. I removed the defective valve and replaced it with the new one. Everything was color coded and the hoses were different sizes, making it impossible to screw up. It was over so fast I thought I made a mistake.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from El Dorado, AR
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Bottom of refrigerator wouldn't coool
I removed the top vent and unplugged the ice machine ,took the back cover off the freezer.Removed the old fan which was pretty easy(unplugged it after I took the housing out for easy access) I plugged the new fan in and put everything back in the order I took off, and yada yada yada we have cooling.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from COLUMBIA, SC
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from Madison, WI
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set, Wrench (Adjustable)
Opend freezer door and found ice everywhere from dripping ice maker. Even with power unplugged water was still leaking through so I determined it must be the water valve at the back of the fridge that had failed.
Unplugged fridge. Shut off the water supply valve under sink. Removed lower access panel at back of the refrigerator (six screws). Removed single green screw holding water valve bracket and pulled assembly out to access wiring and hoses. It is a dual valve as one valve is for the water dispenser and one is for the ice maker. Disconnected the 2 electrical connectors (one for each valve). Unscrewed the compression fitting for the water inlet with 1/2 " wrench. Then the two water lines on the outlet which are quick disconnects. You must push the ring towards the valve and then the tubing can be pulled out by hand.

Reattach everything to the new valve and install and its ready to use.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sumlorq from Cleveland, OH
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light switch freezer door
put the gratefruit knife behind the old switch pooped it out pluged the new one in piece of cake 5min.even vacumed the dust off the coil
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Warrenton, VA
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set, Wrench set
Water was leaking from the cracked plastic valve
1 unplug fridge
2 turn off supply line for ice maker
2 remove lower back panel of fridge
3 disconnect in and out line from valve
4 remove valve (one screw.)
5 disconnect power line to valve.
reverse to reinstall. Very easy.

This valve is a cheap, poor design. This is the second one in 5 years. I replaced the first one because the line in the freezer would "drip" creating an ice dam so the ice maker wouldn't work. This time, the water dispenser on the front of the fridge has been dripping for months - finally the valve just dissolved and was spraying water all over the floor. It ran down into the basement. Keep a eye out if you have a GE fridge.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Glendale Heights, IL
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
Light would stay on when door closed
Extremely easy repair, the hardest part was getting the old switch out. I used a pair of needle nose pliers to squeeze the tabs in and it came right out.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Miamisburg, OH
Parts Used:
WR49X10283
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refrigerator not cooling
1.Google troubleshooting for this issue. Determine the inverter card was bad. Installed new card and correct jumper harness per instructions. Total time to troubleshoot, remove & replace was about 30_45 min. Pretty simple
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gratnie from Newport News, VA
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
Water dispenser would not stop leaking on the unit.
First, turn off main water valve. Then, at the rear of refrigerator remove the rear panel exposing the water valve assembly. Cautiously, proceed by disconnecting the water hose and electrical connections. To complete the task, just worked in the reverse steps to exchange the faulty equipment.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from MATTHEWS, NC
Parts Used:
WR14X10238
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Frayed door gasket
Removed old worn out gasket and installed new gasket
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!