Customer:
louis from floral park, NY
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
evap fan not working.
first i removed the three screws that covered the circuit board that was bad. then i removed the 6 connectors that went from the refrigerator to the board then popped out the old board , popped in the new board reconnected the circuit connectors covered everything back up and my refrigerator is back on line. this all took about 10 to 15 minutes time ... thank you for your product it really did the job..
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Johnnie from KANSAS CITY, MO
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
The Ground wires wasn't in same location on board
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Ft. Lauderdale, FL
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Wasn't Getting Any Water To The Icemaker
It could not have been easier. The new part matched the old part exactly. I turned the water off going to the refrigerator, unscrewed one screw from the old part, pulled the electric plug loose, disconnect the copper water line from old part, cut off the black plastic tube next to the water valve going to the icemaker, and the new water valve was ready to install. It's that simple. I then took the new water valve, connected the copper water line to it, pushed the black plastic water line into its hole, connected the electric plug, and screwed the new part onto the refrigerater. In a matter of minutes I had water running to my icemaker again. I can't imagine the money I saved by doing this simple project myself. This took less than 10 minutes.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Bayside, NY
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Icemaker solenoid housing cracked
The original piece was already removed. installation required a little custom fitting as the mounting was slightly different and the copper tubing from the water line needed to be bent to fit. The push in plastic connection (output to the icemaker itself ) was simple ( I was a little leary of it not leaking.)
I plugged in the solenoid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
O. V. from Virginia Beach, VA
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set, Wrench set
Ice maker water valve failed open.
The replacement single outlet water valve was not an exact replacement and required a slightly different mounting position. The original plastic hose to the ice maker attached to the valve with a plastic nut. The new connection requires only pushing the hose into a hole in the valve. Easy and simple. However, the new mounting angle promptly broke the brittle old plastic hose. I was able to pick the broken pieces of hose out of the valve with a fine point pick saving the new valve. If I hadn't been able to pick the broken pieces out of the new valve I would have had to order another one. Off to the big box store to buy new 1/4 inch plastic hose and a coupler. Repair completed and no leaks. If the hose hadn't broken, the I would have been done in 15 minutes. I suggest you plan to replace the entire plastic hose when you replace the valve.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Tiverton, RI
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer/Fridge not cold & compresser would not turn on.
For troubleshooting, I took off rear panel inside of the freezer compartment & determined that icing of the coils was not the problem & it did not apprear to be a defroster malfunction. All components appeared to be working properly except the compressor would not turn on and only room temperature air was being circulated by the fan. After narrowing the probable causes down to a faulty Main control board by reading as many similar posts as possible,I ordered the new control board. When it arrived the following morning via UPS(less than 24 hours!), I unplugged the wiring connections attached to the old board, (which was somewhat different in appearance), and then gently popped the circuit board off of the plastic retainer studs by pushing in the little retaining clip part of the studs in with a small screwdriver so the board could be released easier as I pulled outward. I popped the new board on the studs by gently & evenly pushing with a larger hut driver over the studs until it was locked in, being careful not to damage or over stress/bend the board. I placed the wiring connecters onto the pins on the board.....every connecter had a different amount of pins so improper connection was not possible. I placed the ground wire connection of the new board between the metal cover plate @ an adjacent screw location to ensure grounding to the back of the fridge sheet metal. I plugged in the refrigerator and was quite relieved when I heard the compressor start up after a second or two! Within moments the temp began to fall until it reached the proper temp in both compartments. Success!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from Crete, IL
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
cracked valve
Super simple. Extremely fast delivery of part. Simply disconnect the 2 fast-on connectors to valve, disconnect intake and out lines. connect intake and out tubes to new unit, mount via screws to fridge, reconnect the 2 fast-on power connectors and your back in business. Could not be an easier repair.
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from Mountain View, AR
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Ice cream melting, lettuce freezing
Removed the back cover over the control board, and made sure that the board was the same. It didn't look exactly the same, but figured that it was the same, just updated. Took out the board, moved the wires to the new board and reinstalled. Plugged it in and it came on, so I reinstalled the cover. Seems to be working to this day.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Clarksville, GA
Parts Used:
WR55X10942C, WR55X24064
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Electric surge from lightening strike close to house
Obvious that main electronic board was fried. Refrigerator and freezer both not working although fan was running. Replaced main board and run capacitor. Compressor not running. Pulled starter relay and checked compressor connections for continuity. Checked ok. Ordered starter relay and installed with new capacitor. Compressor started and has been running quiet and cold ever since. Thanks to videos on partsselect website for offering the confidence to try the fix myself. Total spent on parts and shipping,$350. I had electric provider install surge protection behind meter for a cost of $5.70 a month. Hope it works as advertised.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alice from Vancouver, WA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers, Socket set
Ice maker stopped working.
I first replaced the ice maker and when that didn't work, I found out through this forum that another possibility is the water outlet valve.

When I got the replacement, it took some time to install because the bracket wasn't the same as the original. There are enough places on the bracket to mount the unit, but it may require using some force to bend the bracket so that it will flush with the wall.

After installation, it took about 2 days to fill up the ice bin. It cycles out ice crescents every 2-3 hours.

Thanks partselect for having this forum and saving me some money by having others share their experiences.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cecilia from NATALIA, TX
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer would not freeze and fridge would not cool after power outages
I used a volt/ohm meter and checked for power to compressor and start run relays, diagnosis- was remove and replace motherboard
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
KEITH from WINDER, GA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
broken outlet valve
All the repair people was on the money . I read them all .1--- NO paper work with new valve (.no instructions) ..2--- bracket is not the same .. I reversed my braket and it worked fine .you do not have to bend bracket.3--- It will take a day or so to start making ice..4--- the plastic nut is no longer needed on the new type outlet valve ....5--- the new outlet valve looks a little different from the old valve. WORKS GREAT ..
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from SCOTTSDALE, AZ
Parts Used:
WR55X10025
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
H E from St Simons Island, GA
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator/Freezer Warm & Condenser Fan Not Running
The control board and access panel are on the back of the refrigerator, so you will need to roll/slide the refrigerator away from the wall to gain access to the panel. Be careful not kink the water line if you have an ice maker connection.
Unplug the power cord from power outlet on the wall.
On this model the control board is located behind a rectangular panel that is about 8" x 10". The panel is about 3 feet above the floor on the left side (as viewed looking at the back of the refrigerator).
Using a Phillips (cross point) screwdriver, remove the screws and the access panel cover. Look closely at the control circuit board and you will see 4 small white plastic protrusions sticking through the board -- these are the plastic posts that hold the board in place. There is a small tab that locks the board to the plastic mounting post. Use your needle nose pliers (or other small pliers) to compress the small tab on the post; and while squeezing, pull on the control board until it releases from the post/clip. Repeat this for each of the four posts and the board will now be free from the mounts.
Look at the plugs that connect the wires to the board and note the orientation of each plug. Each plug is a different size, so they will only fit into the socket of the correct size. On my refrigerator, there is one plug that is not connected to the board and is hanging loose, so don't get confused when connecting plugs to the new board - this one remains unconnected.
Firmly pull each plug from its socket on the board -- try not to pull by the wires. If you have a stubborn plug, grab it with your pliers and pull it out. There is a green ground wire connected by a screw into the refrigerator cabinet. Remove this screw and ground wire. (Note: on some models the green ground wire is fastened with a screw that holds the cover in place - just be sure to reconnect the wire when replacing the cover).
Insert all of the plugs into the new board -- be sure they are seated firmly. Reinstall the ground wire. Place the board over the plastic posts and push until the tab locks the board in place. Replace the cover.
On the sheet that comes with the refrigerator they instruct you to remove the lower panel on the refrigerator that covers the compressor motor compartment. They instruct you to look at the power cord connection to the compressor and to locate a green wire from a capacitor. If your power cord does not have a capacitor exactly like the one pictured, there is no need to proceed on this step. Replace the lower panel. If it does have a capacitor as illustrated, follow those instructions and then replace the panel.

Now plug in the power cord to the wall power outlet. Before pushing the refrigerator back into place you want to make sure it is operating properly. To make sure that there is no "Glitch" during start up, I suggest that you set the temperature control inside of the refrigerator to "OFF" and wait about 3 minutes. After 3 minutes, set the control to the desired temperature (about 37 Deg for Refrigerator and 0 Deg for the Freezer).
If the refrigerator is running, you are finished. Being careful not to kink the water line, push the refrigerator back into place.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Philip from Los Alamos, NM
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Cabinet very hot on sides, freezer not 0, running continuously.
Diagnosis of symptoms was condenser fan not running, due to faulty main board.

First: removed the cover over the main board, which was too hot to touch. Bad design flaw, no ventilation for the board, which I believe made it fail. We got another year of service with the cover removed.

Second: after reading people's experiences here, ordered the board and popped it in. (Note: needed a pliers to compress each of the 4 plastic studs holding the board in.) Works like a champ.

Third: did NOT replace the cover. At our altitude the air can't conduct enough heat to prevent cooking the board. Need to allow circulation.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!