PDS22MFWBCC General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Christopher from Chicago, IL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Temp panel flashed "hrs", refrigerator would not work
Remove back panel to expose the control board. Simply unplug cables from old board and pull the board out, no tools required. Put new board in place and replace the cables. Very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jaime from SYLMAR, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
No Cooling on either freezer or refrigerator
Everything seemed to be working right, but no cooling, so I tried turning on and off the switch that turns the light on 5 times within two seconds, refrigerator did not shot. so I removed the main board and I notice a short had taken place on one of the relay legs. I ordered the main board and replaced it. The main board is on the back of the freezer covered with a sheet metal panel about 8"x8" and is secured with hex sheet metal screws. Everything is working now. Please make sure to unplug the unit from power before removing the main board.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from BELLVILLE, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Unit was dead
Removed and replaced control board
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from VERO BEACH, FL
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The Refridgerator and Freezer were not cooling.
Installing the part repaired the fridge and freezer immediately.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sonya from Sugar Land, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
no water from dispenser, then constant clicking sound, and frig went warm
After reading this forum and other searches, I assumed replacing the board may solve my problem. Unscrewed the back plate, used pliers to pull out the connectors, squeezed in the sides of the 4 plastic white board holders to release the board, and then replaced old board with the new one and reconnected connectors. (My model was not one of the mentioned models for cutting the 2nd pin of the J1 connector, so I left it in.) Upon plugging my frig back in, it began working perfectly again. So thankful to have found this forum!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from DURYEA, PA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Morris from PORTER, TX
- Parts Used:
- WR02X11666
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 30 - 60 mins
The problem is that there are no instructions at all
I could not complete the repair and by repair meaning removing the other parts from the original Lower Pan Frame and re-installing them on the new Lower Pan Frame so that the new Lower Pan Frame works as intended. The Lower Pan Frame contains other ancillary parts that must be removed and then reinstalled into the new Lower Pan Frame before the new Lower Pan Frame could be used as intended. The other parts were difficult and next to impossible (at least to me) to remove from the original Lower Pan Frame for re-installation into the new Lower Pan Frame. There are no instructions at all on how to do this unless one is very good at reverse engineering plastic parts that clip onto the Lower Pan Frame. I abandoned the effort and used the new Lower Pan Frame to the best I could. I would not recommend ordering this part from PartSelect. Waste of money for me ...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from HAVANA, FL
- Parts Used:
- WR02X11666
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
Drawer guides broken on both drawers.
No directions supplied with product. Be very careful to not break the old parts moving them to the new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Trudy from Saint Cloud, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator would not get cold
UNPLUG! (Read Instructions for wiring configuration) Remove cover lower back right hand side.Remove ribbon plugs top and bottom you will need to lever back holding tab while pulling plug they will more than likely break dont worry you are throwing this part away., disconnect ground wire, compress plastic holding tabs,
pull off control board, plug in new board push on to holding tabs reconnect ground and turn on refrigerator and check replace cover, everything is now working great.
pull off control board, plug in new board push on to holding tabs reconnect ground and turn on refrigerator and check replace cover, everything is now working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cliff from ROCKVILLE, VA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench set
The old solenoid was slow to shut off causing the icemaker to overfill.
Unplug refrigerator and turn water supply off to the ice maker. Remove the screws holding the bottom cardboard-like cover from the lower back of the refrigerator. Remove the water supply line to the old solenoid with 1/2 inch wrench. Unplug the two power supply wires to the old solenoid. Remove the screw that holds the solenoid to the back panel of the unit. After the solenoid is pulled out, remove the output hose with a 1/2 inch wrench. The configuration of the replacement solenoid is likely a little different than the original, but it seems to be rather universal and will fit back into place and perform properly. The new solenoid does not use a compression type nut to secure the output line. It's just a simple push-in connection. The wires may have to be rerouted a little, just keep them clear of the evaporator fan blades Reverse the removal procedure and you're done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Margaret from Virginia Beach, VA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
Ice maker would only make very small and very few ice cubes.
After determining that the ice maker on this relatively new refrigerator would make ice cubes if it received the proper amount of water. Ordered the valve and received in a couple days. Using a nut driver, removed the cardboard cover from the back of the refrigerator. Removed one screw holding the valve bracket to the fridge and removed another screw holding the water supply line and the water line to the ice maker in place. Pulled plug on fridge and removed 2 wires from valve. Removed inlet and outlet lines from old valve and reversed the process installing the new valve.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randall from Cumming, GA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Wrench set
Water valve for ice maker leaking
Other than having to bend the bracket 90 degrees it was an easy install.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Jacksonville, FL
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Ice Maker Did Not Work
Tried replacing water valve since no water in ice cube tray. Exact part not available due to age of refrigerator, but I got the equivalent replacement part for $18. Mounting holes different, but I made it work. Also one connect on new one slip connect whereas both compression fittings on old valve. I put it back together and icemaker now works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from ROSEMOUNT, MN
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Cheyenne, WY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Periodic and intermittent "clicking," during which the lights on the temp control unit would go out. When clicking stopped and lights returned, temp control unit was not accepting adjustments in temp
Had friend assist in pulling fridge out from it's area so that I could access back. Unplugged unit. For the bottom freezer units (mine) the compartment containing the main control board is middle of the fridge and on the left. Took off the protective metal plate and then followed the video demonstrating the repair. One other discrepancy between the video and the instructions that came with the new main control board, is that the instructions suggested locating and cutting some other green wire to the compressor unit. I chose not to do that, as the unit was otherwise working fine as is prior to my main control board going south.
Was this instruction helpful to you?
Thank you for voting!