GSE22KEWNFBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Andy from Villa Rica, GA
- Parts Used:
- WR17X11497
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
ice maker would not dispense due to a broken crusher cover
I removed and cleaned out the ice tray, then removed the ice auger. Next I had to remove the front cover of the tray that housed the crusher, this was done by removing to screws on the bottom and sliding the crusher section, once the crusher section was removed I simply slid off the crusher cover and replaced with the new one and put it back together. It was that simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerard from STATEN ISLAND, NY
- Parts Used:
- WR17X23191
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
auger broken
took out old ice bucket put in new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from FARMINGVILLE, NY
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refrigerator not cold
removed freezer door / shelf /ice maker pulled back panel off and removed fan
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Lincoln, CA
- Parts Used:
- WR01X37886
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light burned out
unscrewed lamp and replaced it with new one!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clyde from RIALTO, CA
- Parts Used:
- WR60X24484, WR60X10209
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bert from SAN JOSE, CA
- Parts Used:
- WR60X30922
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little retaining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Austin from New Portland, ME
- Parts Used:
- WR01X37886
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
ice door light bulbs burned out
found the correct bulbs, the hardest part.
un screwed old bulb.
Screwed in new bulb.
Waa La,
There was light.
un screwed old bulb.
Screwed in new bulb.
Waa La,
There was light.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Walter from Buena Vista, VA
- Parts Used:
- WR29X43990
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Broken Auger
I followed the video and things went well. Glad I had the video.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Hereford, AZ
- Parts Used:
- WR29X43990
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
auger was broken
I followed the video supplied at the part selection site. If you follow the video the repair will be easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Lawerence, MI
- Parts Used:
- WR17X11505
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice would fall after removing glass.
I took the ice drawer out and turned it upside down. Then removed two philips screws holding the drawer front on. Then with a small straight edge screwdriver pry out the sides to release the locking tabs and remove the auger and crusher assembly. Then on the end of the auger remove the e-clip, slide the auger out and remove the broken part of the crusher dispenser and replace with new. Easier than it sounds. Parts Select was great to deal with. Had my parts in two days.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from SCOTTSDALE, AZ
- Parts Used:
- WR55X10025
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- randall from coopersville, MI
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
refriderator not cooling consistetly
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gail from SARATOGA SPGS, UT
- Parts Used:
- WR72X10233
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
ice bucket support (glide) had broken allowing misalignment of rotor which then broke.
Removed ice bucket and emptied it, storing ice cubes temporarily in another container; Removed broken support and replaced with new. Removed rotor/crusher assembly from ice bucket assembly, replaced broken rotor (other vendor), reassembled ice bucket, filled with stored cubes and reinstalled in freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from HIXSON, TN
- Parts Used:
- WR17X23191
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
ice despensor auger was broken
Remove the broken bucket and install the new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- IRISA from TAMPA, FL
- Parts Used:
- WR32X10834
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
broken off side support
exchanged
Was this instruction helpful to you?
Thank you for voting!