- Customer:
- William from Provencal, LA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
ice maker barely working
Repair was very simple. Removed refridgerator bottom back panel, about 6 or 7 screws. disconnected bad valve, installed new valve , connected water supply line and then reinstalled panel. Took about 15 minutes from start to finish.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Fresno, CA
- Parts Used:
- WR02X11706
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
broken dairy door cover
removed old one and installed new one. 30 seconds.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Ft. Lauderdale, FL
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Wasn't Getting Any Water To The Icemaker
It could not have been easier. The new part matched the old part exactly. I turned the water off going to the refrigerator, unscrewed one screw from the old part, pulled the electric plug loose, disconnect the copper water line from old part, cut off the black plastic tube next to the water valve going to the icemaker, and the new water valve was ready to install. It's that simple. I then took the new water valve, connected the copper water line to it, pushed the black plastic water line into its hole, connected the electric plug, and screwed the new part onto the refrigerater. In a matter of minutes I had water running to my icemaker again. I can't imagine the money I saved by doing this simple project myself. This took less than 10 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- O. V. from Virginia Beach, VA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench set
Ice maker water valve failed open.
The replacement single outlet water valve was not an exact replacement and required a slightly different mounting position. The original plastic hose to the ice maker attached to the valve with a plastic nut. The new connection requires only pushing the hose into a hole in the valve. Easy and simple. However, the new mounting angle promptly broke the brittle old plastic hose. I was able to pick the broken pieces of hose out of the valve with a fine point pick saving the new valve. If I hadn't been able to pick the broken pieces out of the new valve I would have had to order another one. Off to the big box store to buy new 1/4 inch plastic hose and a coupler. Repair completed and no leaks. If the hose hadn't broken, the I would have been done in 15 minutes. I suggest you plan to replace the entire plastic hose when you replace the valve.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Bayside, NY
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Icemaker solenoid housing cracked
The original piece was already removed. installation required a little custom fitting as the mounting was slightly different and the copper tubing from the water line needed to be bent to fit. The push in plastic connection (output to the icemaker itself ) was simple ( I was a little leary of it not leaking.)
I plugged in the solenoid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
I plugged in the solenoid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alice from Vancouver, WA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Ice maker stopped working.
I first replaced the ice maker and when that didn't work, I found out through this forum that another possibility is the water outlet valve.
When I got the replacement, it took some time to install because the bracket wasn't the same as the original. There are enough places on the bracket to mount the unit, but it may require using some force to bend the bracket so that it will flush with the wall.
After installation, it took about 2 days to fill up the ice bin. It cycles out ice crescents every 2-3 hours.
Thanks partselect for having this forum and saving me some money by having others share their experiences.
When I got the replacement, it took some time to install because the bracket wasn't the same as the original. There are enough places on the bracket to mount the unit, but it may require using some force to bend the bracket so that it will flush with the wall.
After installation, it took about 2 days to fill up the ice bin. It cycles out ice crescents every 2-3 hours.
Thanks partselect for having this forum and saving me some money by having others share their experiences.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Crete, IL
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
cracked valve
Super simple. Extremely fast delivery of part. Simply disconnect the 2 fast-on connectors to valve, disconnect intake and out lines. connect intake and out tubes to new unit, mount via screws to fridge, reconnect the 2 fast-on power connectors and your back in business. Could not be an easier repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- KEITH from WINDER, GA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
broken outlet valve
All the repair people was on the money . I read them all .1--- NO paper work with new valve (.no instructions) ..2--- bracket is not the same .. I reversed my braket and it worked fine .you do not have to bend bracket.3--- It will take a day or so to start making ice..4--- the plastic nut is no longer needed on the new type outlet valve ....5--- the new outlet valve looks a little different from the old valve. WORKS GREAT ..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- randall from coopersville, MI
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
refriderator not cooling consistetly
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rickey from DUMAS, AR
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugged it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from SCOTTSDALE, AZ
- Parts Used:
- WR55X10025
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rene from HEBER, CA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
condenser icing refrigerator warm freezer ok
follow the easy instructions replace 3 temperature sensors cut the wires and crimp them with new sensor and it works like new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from WEST WARWICK, RI
- Parts Used:
- WR17X11606
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
bin broke
Take out of box from this site put on door all done. Less than 30 seconds no problems
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from ORO VALLEY, AZ
- Parts Used:
- WR57X10033
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water leaking from bottom of refrigerator
I'm not a DIY-er, and wasn't sure a 20 year old refrigerator was worth the repair, but for $30 I could afford to be wrong. The swap is pretty intuitive, especially in my case since the problem was that the water tube from the valve to the ice maker had detached from the coupling. So I didn't have to cut anything off, just inserted the tube into the new valve. Reconnected the supply line, screwed the assembly back on the refer, and Bob's your uncle. Other than unloading some canned goods to lighten the refer, longest process was finding the right size nut driver in my disorganized tool tray. Be aware, there are NO instructions included with the part. Found a good video on you tube that confirmed the obvious. Glad I took a shot!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!