Rudolph from Arroyo Grande, CA
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
evap coil freezing up every 2 weeks
removed 2 - 1/4" screws and 2 phillip screws to take off the evap cover, then 2 phillip srews to take out the defrost heater assembly, replaced and put everything back together. no problem.
I GOT THE PART SO FAST THAT I WAS SURPRISED TO SEE IT THERE!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
randall from coopersville, MI
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
refriderator not cooling consistetly
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Pat from Pensacola, FL
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
No ice or water at the despenser. Compressor would turn off when the dispenser lever was pushed. There was also a loud buzzer sound for a couple of weeks prior to the board failing.
Pulled out the fridge and unplugged electric cord. Took off the back lower right side panel. Unplugged all the connectors and removed the motherboard. Replaced the motherboard and reconnected connectors. Replaced the panel and plugged it in. Works great!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
LEE from WILMINGTON, DE
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
clicking nose from mother board
pulled the board away from the 4 plastic pins, unplugged the wires and plugged them directly into the new noard, pushed board back onto the four plastic pins.......job completed in under 5 minutes. Fridge working fine now for over a week......no problems.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Coto de Caza, CA
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Debbie from Tujunga, CA
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
no cooling hrs display
I removed the board, unplugged all the sockets, took the new board, plugged in all the sockets, and replaced the new board into the refrigerator. I was to applaud this business. I was first able to diagnose the problem by finding this site, then one of the customers explained how to fix the problem ourselves. It save us at least $100. The $25 overnight shipping fee was well worth it. We could have lost $100's of dollars worth of food.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Akron, PA
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Compressor Would not come on. Found the relay on the Main Board burned up. There was no electrical power to the compressor .
Ordered a new Main circuit Board. It arrived next day. Unplug the fridge to take away electrical power. Unscrewed the panel on the back of the fridge near the top. I then pulled the wire connectors off the circuit board. Gently pull the board off the plastic tabs. Push the new board onto the tabs. Reconnect the wire connectors. Screw the panel back on.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
H E from St Simons Island, GA
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator/Freezer Warm & Condenser Fan Not Running
The control board and access panel are on the back of the refrigerator, so you will need to roll/slide the refrigerator away from the wall to gain access to the panel. Be careful not kink the water line if you have an ice maker connection.
Unplug the power cord from power outlet on the wall.
On this model the control board is located behind a rectangular panel that is about 8" x 10". The panel is about 3 feet above the floor on the left side (as viewed looking at the back of the refrigerator).
Using a Phillips (cross point) screwdriver, remove the screws and the access panel cover. Look closely at the control circuit board and you will see 4 small white plastic protrusions sticking through the board -- these are the plastic posts that hold the board in place. There is a small tab that locks the board to the plastic mounting post. Use your needle nose pliers (or other small pliers) to compress the small tab on the post; and while squeezing, pull on the control board until it releases from the post/clip. Repeat this for each of the four posts and the board will now be free from the mounts.
Look at the plugs that connect the wires to the board and note the orientation of each plug. Each plug is a different size, so they will only fit into the socket of the correct size. On my refrigerator, there is one plug that is not connected to the board and is hanging loose, so don't get confused when connecting plugs to the new board - this one remains unconnected.
Firmly pull each plug from its socket on the board -- try not to pull by the wires. If you have a stubborn plug, grab it with your pliers and pull it out. There is a green ground wire connected by a screw into the refrigerator cabinet. Remove this screw and ground wire. (Note: on some models the green ground wire is fastened with a screw that holds the cover in place - just be sure to reconnect the wire when replacing the cover).
Insert all of the plugs into the new board -- be sure they are seated firmly. Reinstall the ground wire. Place the board over the plastic posts and push until the tab locks the board in place. Replace the cover.
On the sheet that comes with the refrigerator they instruct you to remove the lower panel on the refrigerator that covers the compressor motor compartment. They instruct you to look at the power cord connection to the compressor and to locate a green wire from a capacitor. If your power cord does not have a capacitor exactly like the one pictured, there is no need to proceed on this step. Replace the lower panel. If it does have a capacitor as illustrated, follow those instructions and then replace the panel.

Now plug in the power cord to the wall power outlet. Before pushing the refrigerator back into place you want to make sure it is operating properly. To make sure that there is no "Glitch" during start up, I suggest that you set the temperature control inside of the refrigerator to "OFF" and wait about 3 minutes. After 3 minutes, set the control to the desired temperature (about 37 Deg for Refrigerator and 0 Deg for the Freezer).
If the refrigerator is running, you are finished. Being careful not to kink the water line, push the refrigerator back into place.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
HUAHUI from NEW HYDE PARK, NY
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator cannot generate cool air
I bought the GE Refrigerator about 4 years ago for about $1500. The defrost Heater failed about one year ago. Then I called local repair guy, he replaced the Defrost Heater and charged me about $250. Now it happened again. I think we should try it to fix it by myself. I found the parts from partselect.com, it costs me $50 with 2-3 days shipping. After it replaced, it works fine again.

Note: Symtom: cannot make cool air, Frozen area with frost on the wall. Regeriator "leaking water" on floor since iced food started to melt...

Solution: open the cover of the wall inside of frozen zone, use hot water to defrost it gradually. removed the failed Defrost Heater and replaced it with new one.

Note: after you defrost the area inside of the wall, your refrigerator will work normally without the Defrost heater without any issue about week while you are waiting for the parts coming.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Grass Lake, MI
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer coils would freeze
Turned the power of to the fridge took the food out of the freezer put in the fridge took out all the shelves and took off the panel to get to the coils. I used a hair dryer and a shop vac to defrost the coils used the shop vac to suck up the water as the ice melted also put some paper towel in the drip tube so the water would not go to the drip pan. Took off old defrost heater which was a single heater the new on was a double heater fished out the blue wire from the left side of compartment and ran it down the right side plugged both wires into the heater mounted it into place and put everything back. Turned on fridge and it has been working fine ever since. Thanks for the last person that did this I read his review and it really was that easy
Thanks Jerry
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from BENSALEM, PA
Parts Used:
WR60X10220, WR60X10207, WR02X10098
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Noise from Condensor Fan and Fan Motor.
I watched the video provided by PartSelect twice, then proceeded with the removal and installation. It took me 40 minutes from start to finish. Piece of Cake. Everything works fine now.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from SCOTTSDALE, AZ
Parts Used:
WR55X10025
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Desiree from Greensburg, PA
Parts Used:
WR60X10220
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Ref was not freezing correctly
took back cover off. swept the rear with a vacuum cleaner to get rid of dust.found that the fan would not turn. ordered part with your really great ordering technique. Part was suppose to be here in 3-5 days and was here the next day!!!.Removed 2 bolts pulled out the plastic clip that held the wire on. and worked the fan blade off shaft. removed and replaced in the same order as taking simple Thanks
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eileen from Coto de Caza, CA
Parts Used:
WR23X37285
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from The Villages, FL
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Refridgerator was not cooling
First, I removed the cover plate from behind the fridge. Next, I carefully pulled the main board out (four little clips holding it in) and disconnected the plug in wires. I connected the wires to the new board, popped it back in place and replaced the cover. Very easy to do.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GSS20DBTNWW