- Rene from HEBER, CA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
condenser icing refrigerator warm freezer ok
follow the easy instructions replace 3 temperature sensors cut the wires and crimp them with new sensor and it works like new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- anthony from Hampton, NJ
- Parts Used:
- WR50X10068, WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Defrost cycle would not cycle off
Replaced Defrost Thermostat. Tricky removal of light fixture cover and evaporator cover. Light cover screw removal is not intuiitive and the eveaporator cover tabs are not easy AT ALL to remove.Once they are removed, simply 2 screw removal of rear panel.
Had to unscrew screws holding cooling coils to gain access to thermostat mounted on a coil in rear.
Simkple matter to cut wires, remove old thermostat and splice replacement back on. Found it simpler to re-mount thermostat on top coil greatly simplifying process.(Why didn't they place the original unit in this much more accesible place?)
Re-attach coils to rear wall replace rear panel, light fixture cover and evaporator cover.
Refrigerator has been running fine this past week.
Received parts NEXT DAY! FANTASTIC!
Had to unscrew screws holding cooling coils to gain access to thermostat mounted on a coil in rear.
Simkple matter to cut wires, remove old thermostat and splice replacement back on. Found it simpler to re-mount thermostat on top coil greatly simplifying process.(Why didn't they place the original unit in this much more accesible place?)
Re-attach coils to rear wall replace rear panel, light fixture cover and evaporator cover.
Refrigerator has been running fine this past week.
Received parts NEXT DAY! FANTASTIC!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from West Winfield, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
The fridge was making a clicking sound, and not cooling the food
The back panel was unscrewed, we read the directions with the circuit board and followed them. It was very easy to unplug the old faulty unit and plug in the new replacement part. It was done in 4 minutes flat. Very easy to do yourselves!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Trudy from Saint Cloud, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator would not get cold
UNPLUG! (Read Instructions for wiring configuration) Remove cover lower back right hand side.Remove ribbon plugs top and bottom you will need to lever back holding tab while pulling plug they will more than likely break dont worry you are throwing this part away., disconnect ground wire, compress plastic holding tabs,
pull off control board, plug in new board push on to holding tabs reconnect ground and turn on refrigerator and check replace cover, everything is now working great.
pull off control board, plug in new board push on to holding tabs reconnect ground and turn on refrigerator and check replace cover, everything is now working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randall from Sterling Hts, MI
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
unit was not cooling, evaporator was iced over
This is the third time the defrost heater has failed, the part was shipped prompt, and the replacement was upgraded to a dual coil. The repair was quick and more cost effective than having a repair guy come out .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Point Pleasant, NJ
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer iced up, no air circulation
Removed the back panel of the freezer to inspect. The coils were totally iced up. Proceeeded to defrost coils with a heat gun. I then removed the defrost element to insepct and meter reading showed as open (infinite resistance). I ordered a replacement element and it arrive 2 days later. Replace the element and everything worked OK except for the ice maker. It seem that moisture had frozen on the motor impeller for the auger drive motor and locked it up. I removed the drive assembly and defrosted the motor impeller to free it. Everthing now is working fine.
Your blow up drawings made this a very easy repair
Thanks
Your blow up drawings made this a very easy repair
Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Chicago, IL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Temp panel flashed "hrs", refrigerator would not work
Remove back panel to expose the control board. Simply unplug cables from old board and pull the board out, no tools required. Put new board in place and replace the cables. Very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from DURYEA, PA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Ooltewah, TN
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator and freezer started loosing its cool
Removed cover exposing defrost heater. Defrosted the cooling system. Removed screws holding defroster, replaced old with new, by way of two quick connect eletrical clips. replaced cover. Pretty easy once I figured our that it was the defroster and not the timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- DONALD from LONGS, SC
- Parts Used:
- WR50X10068, WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
freezer was freezing up cutting off cold aire to fridge side. Ice cubes became thin and clear.freezer was constantly running compresser.
I first bypassed the thermostat by cutting wires and splicing them together. This made no difference. I then saw that the defrost heater glass looked dark and may be burnt out. I replaced thermostat and defrost heater in 15 minutes with the parts from part select that arrived in less than three days. I believe the thermostat was the problem and now freezer works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sonya from Sugar Land, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
no water from dispenser, then constant clicking sound, and frig went warm
After reading this forum and other searches, I assumed replacing the board may solve my problem. Unscrewed the back plate, used pliers to pull out the connectors, squeezed in the sides of the 4 plastic white board holders to release the board, and then replaced old board with the new one and reconnected connectors. (My model was not one of the mentioned models for cutting the 2nd pin of the J1 connector, so I left it in.) Upon plugging my frig back in, it began working perfectly again. So thankful to have found this forum!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Purcellville, VA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Fridge evaporator coils frozen
Determined that the defrost heater was bad (didn't test the thermostat or sensor) and attempted to replace it first.
Got the part in one day (super fast shipping).
1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Got the part in one day (super fast shipping).
1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from Damon, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Fan was not running to circulate the air; found resistors burned on main board
Removed the board cover from the back, removed old board, installed new board, installed cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Marrero, LA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Main Board failed
Part arrived 2 days before anticipated. I was able to keep my fridge running long enough to get the new part in, which took no time at all. The Main Board relay would start clicking and the compressor would shut down. By unplugging the top right plug for a minute and plugging it back in I was able to keep it running for a few hours at a time. Good enough to keep my food from going bad. Thr part was an easy plug in replacement, was a good price, and works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from Madison, OH
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Lost Temperature in Refrigerator and Freezer, making clicking noise
Removed main control board cover on back of refrigerator (3 screws). Unplugged power to refrigerator and removed electrical connections to control board using a screwdriver. Using a screwdriver disconnected (4) plastic self -locking prongs holding the board. Matched new replacement board with old board. Plugged in electrical connections to new board. Snapped main control board onto (4) self- locking prongs. Reinstalled cover (3) screws. Plugged in refrigerator and tested refrigerator operation.
Was this instruction helpful to you?
Thank you for voting!