GSS20DBPAWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Eric from NEW YORK, NY
- Parts Used:
- WR02X10520
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Noisy refrigerator
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from FRANKLIN SQ, NY
- Parts Used:
- WR23X37285
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
light not working
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rachel from LUDOWICI, GA
- Parts Used:
- WR50X10068, WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Would not defrost
Replaced defrost thermostat along with temp sensor watched the video on this page simple fix
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randolph from Lynchburg, VA
- Parts Used:
- WR60X10074
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers, Wrench set
Refrigerator was noisy when running. The noise increased with time and got so loud it hurt your ears with a high pitch sound.
Empy all the food from the freezer and remove the ice container and the lower ice maker section with a 1/4 inch nut driver, unplug the unit and set aside. Remove all shelving and set aside. Remove light cover and unscrew the bulb and remove. Remove cover/with light fixture by removing the necessary screws with the nut driver. The cover has the fan assembly attached; unplug and remove fan assembly, remove the thermistor from coil attached with a clip. Reassemble in the reverse procedure.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jonathan from NEW ORLEANS, LA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator and freezer would stop cooling. Would happen suddenly without warning. Reset of refrigerator would solve the problem and it would run fine for several days before doing it again.
Only tool I used was 1/4 inch socket. Using the 1/4 inch socket, the screws were removed from the panel covering the control board. (this is on the back in the lower right corner). When this panel is off you are looking at the control board. Next remove all the plug in connectors. Don't worry about remembering where they go. They all are different and can only go in their specific place. After removing the connectors, pull the board out. Replace the plug in connectors before putting the new board back in , then snap the board back into place.(held in by four pins). Replace the cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Seaford, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Freezer stayed cold but Fridge got warm every 3 weeks
Unplug the fridge, then:
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and place a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed
I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.
Thank You PartSelect!
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and place a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed
I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.
Thank You PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Albert from Fort Wayne, IN
- Parts Used:
- WR51X10101, WR50X10068
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Defroster heater burned out
First I defrosted the evaporator core with a hair drier, making sure to disconnect the power before hand. I pretty much followed the directions included with the part, which by the way were excellent, and very detailed. The alternatives were call a repair man for around $300.00 plus parts or take less than a $40.00 gamble. Or even replace the refrigerator at $1400.00. It was the diagnostic portion of your website that convinced me that I had found the problem and that I could repair it myself with a minimum of effort. Needless to say I will come to this site in the future before calling a repair person. The refrigerator is working just fine now. I had my parts in three days, thank you for your attention to detail and a all around positive repair experience. George Day
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from White Pine, TN
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Would not cool top or bottom
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Sylva, NC
- Parts Used:
- WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Ice cubes froze in the tray and frost was all underneath
I read stories from the website how others did it so I figured I would give it a try. I put all the frozen stuff in the refrigerator piled up. Took out the shelves. Took out 2 screws with a socket extension ( nut driver will work fine.) Remove the light bulb. lifted up on the back panel...it came right out. Saw the coils and on top the sensor. Took it off, cut the wires, spliced in the color coded new one ( pink to pink, orange to orange) Stuck it in the top coil in the original position and crossed my fingers! I put all the pieces back easily, restocked the freezer and waited. HOORAY!! My ice cubes are all separate and free. NO frost inside. A very easy fix for $20.
Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- louis from floral park, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
evap fan not working.
first i removed the three screws that covered the circuit board that was bad. then i removed the 6 connectors that went from the refrigerator to the board then popped out the old board , popped in the new board reconnected the circuit connectors covered everything back up and my refrigerator is back on line. this all took about 10 to 15 minutes time ... thank you for your product it really did the job..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Sweet Home, OR
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
evaporator coils iced up causing no cooling in freezer or fridge.
First I disconnected the Power from the unit. Pulled out the freezer drawers and the ice machine used a 1/4 inch nut driver and removed the sheet metal from the back of the freezer exposing the evaporator coils. I defrosted the coils. Then I removed the two screws holding the defrost heater braket assembly and removed the two electrical connections from it. I then installed the new heater put everything back together(reverse of installation)and it works like a brand new fridge and freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clyde from RIALTO, CA
- Parts Used:
- WR60X24484, WR60X10209
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from EL DORADO HLS, CA
- Parts Used:
- WR50X10068, WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
freezer frosting in back, refrigerator compartment warm
I followed the partselect videos for the temp sensor and defrost thermostat and the refrigerator has been working well for a about a week now. The refrigerator is old enough that I was just going to replace it. When I called the repair company I use, they said it would cost $200 to $300 for the repair, but I didn't want to put that money into an old refrigerator. I did a little research, found this site and figured it would be worth buying about $20 in parts and giving it a try. I have absolutely no experience working on refrigerators, but the videos were so easy to follow, everything went smoothly. The old thermostat was definitely broken when I checked it with a meter, so I'm pretty confident that the problem is fixed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnnie from KANSAS CITY, MO
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
The Ground wires wasn't in same location on board
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Tiverton, RI
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer/Fridge not cold & compresser would not turn on.
For troubleshooting, I took off rear panel inside of the freezer compartment & determined that icing of the coils was not the problem & it did not apprear to be a defroster malfunction. All components appeared to be working properly except the compressor would not turn on and only room temperature air was being circulated by the fan. After narrowing the probable causes down to a faulty Main control board by reading as many similar posts as possible,I ordered the new control board. When it arrived the following morning via UPS(less than 24 hours!), I unplugged the wiring connections attached to the old board, (which was somewhat different in appearance), and then gently popped the circuit board off of the plastic retainer studs by pushing in the little retaining clip part of the studs in with a small screwdriver so the board could be released easier as I pulled outward. I popped the new board on the studs by gently & evenly pushing with a larger hut driver over the studs until it was locked in, being careful not to damage or over stress/bend the board. I placed the wiring connecters onto the pins on the board.....every connecter had a different amount of pins so improper connection was not possible. I placed the ground wire connection of the new board between the metal cover plate @ an adjacent screw location to ensure grounding to the back of the fridge sheet metal. I plugged in the refrigerator and was quite relieved when I heard the compressor start up after a second or two! Within moments the temp began to fall until it reached the proper temp in both compartments. Success!
Was this instruction helpful to you?
Thank you for voting!