GTS22KCPDRBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Matthew from Escondido, CA
- Parts Used:
- WR02X12008
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Fan making noise.
Remove ice maker and all of it's accessories in order to remove the panel covering the fan. Don't drop the screws!
Unscrew the lower fan bracket. You will see the lower red rubber grommet. Hold fan motor with one hand and push the fan off the shaft and into the compartment above. Then remove the round retainer thing below it by holding it and pulling down on the motor assembly. Install new grommet on upper part. and put it all together.
REMEMBER where the fan is on the shaft. It has about one inch of shaft placement. I put mine so that most of it was above the hole that the fan goes into and about 20 percent showing below the sheet metal.
Also check to see if your fan is damaged. Mine was not.
This refrigerator has been awesome! I have had many issues but have been able to fix all of them for the last 15 years!
Unscrew the lower fan bracket. You will see the lower red rubber grommet. Hold fan motor with one hand and push the fan off the shaft and into the compartment above. Then remove the round retainer thing below it by holding it and pulling down on the motor assembly. Install new grommet on upper part. and put it all together.
REMEMBER where the fan is on the shaft. It has about one inch of shaft placement. I put mine so that most of it was above the hole that the fan goes into and about 20 percent showing below the sheet metal.
Also check to see if your fan is damaged. Mine was not.
This refrigerator has been awesome! I have had many issues but have been able to fix all of them for the last 15 years!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Diana from DINGMANS FRY, PA
- Parts Used:
- WR60X10220
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Socket set
Fan motor stopped turning.
Removed the fan blade then removed the motor. Replaced motora nd Installed fun blade.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ken from THE VILLAGES, FL
- Parts Used:
- WR50X10068
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Frosting up in freezer ice freezing solid
Took out freezer rack took off the back panel also light bulb found the DEFROST THERMOSTAT cut the 2 wires remove the thermostat strip the wires on the new thermostat splice the to wires together with wire nut wrapped wire nuts with electrical tape put new thermostat back were the old came off of put panels back in place also the racks and bulb plunged in the power and guess what it works like a Champ with in 1 hour making ice and going through defrost cycle nice Thank You Guys for your video and the how to do Thanks Ken
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rafael from New Haven, CT
- Parts Used:
- WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
ice on the frezer compartment
turn off the refrigerator,then open the cover and saw lot of ice. then get a hair dryer blower and blow a heat to melt the ice. cut the thermostat defrost.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from LEAGUE CITY, TX
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Change bulb
Easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mahvash from Gold Canyon, AZ
- Parts Used:
- WR50X10068
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refridgerator warm, some ice buildup apparent in freezer
Find online diagram of freezer section for reference. Disconnect power, remove evap cover plate (214) by removing one of the drawer guide rails.
As evidence of your problem, you might see a giant block of ice built up around the coil. Let this defrost this before continuing.
Find THERMOSTAT DEFROST (24) sensor and clip connecting wires. Match replacement sensor wires by color. Twist and solder wires; or wire-nuts and twisting alone might be okay. If not soldering, seal the wire-nuts connections from moister with a good sizeable piece of duct tape. Make sure your wires are out of the way and not left dangling on the evap heater coil, where they could melt.
Suggest concurrent replacement of evap fan motor if this has not already been done in the past.. This become noisy with age and damage from the ice build up seems to have made mine worse.
As evidence of your problem, you might see a giant block of ice built up around the coil. Let this defrost this before continuing.
Find THERMOSTAT DEFROST (24) sensor and clip connecting wires. Match replacement sensor wires by color. Twist and solder wires; or wire-nuts and twisting alone might be okay. If not soldering, seal the wire-nuts connections from moister with a good sizeable piece of duct tape. Make sure your wires are out of the way and not left dangling on the evap heater coil, where they could melt.
Suggest concurrent replacement of evap fan motor if this has not already been done in the past.. This become noisy with age and damage from the ice build up seems to have made mine worse.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephanie from KEARNY, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light was flicking
It was way to ez to install only a couple of minutes that's it
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ted from SANDWICH, IL
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken light switch
took a little more effort than the video show to remove old module and replace new. Works fine now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patrick from Punta Gorda, FL
- Parts Used:
- WR50X10068
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Rear of freezer all iced up would not defrost
first removed two srews removed rear panel hair dryer to melt ice (took 30 minutes) cut two wires to thermostat spliced onto new part clipped it onto tube -done replace rear panel and 2 screws. very easy job after reading other letters and their experience -saved myself $500.00
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from Bartlesville, OK
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Eugene, OR
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The door activated light switch was missing.
Pulled the two wires out from the access hole in the lower part of the refrigerator. Put them in the spade connectors on the new switch, and pushed the switch into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from Greenbelt, MD
- Parts Used:
- WR50X10068
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
defrost problem
I replaced the thermostat. I simply followed the insructions in the video on your website and it was done in about 5-10 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from cleburne, TX
- Parts Used:
- WR50X10068
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
warm, refrigerator/freezer,frozen up
verify the heating element was o.k., found the top of the thermostat popped off,it had water in it,probably froze and came apart,cut the wires to the old thermostat and splice the new ones together,put the cover back on and verify operation
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Boyd from Rapid City, SD
- Parts Used:
- WR02X10098
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
The evaporator fan in the freezer compartment began making a loud noise.
I found a replacement evaporator fan motor and 2 mounting bracket grommets at PartSelect.com at a reasonable price. I watched the installation video provided and installed the new parts as shown in the video start to finish installation time 22 minutes.i
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jerome from Knoxville, TN
- Parts Used:
- WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Frost buildup causing freezer to warm up
Unplug the refrigerator. Pull all shelves out of the freezer. Remove light bulb shield and light bulb. Remove the two hex head screws on either side of the light bulb. Wiggle out the back wall. It is a tight sqeeze, but can be done. Locate the sensor on the top of the coils. It is held on by a simple clip. Wiggle the sensor and twist a little to take it off. Take wire cutters and cut the two wires into the sensor near the sensor to allow lots of room to splice in the new sensor. Strip about a quarter inch of wires left in the freezer. Use some sort of wire connectors, like twist caps, which will allow you to connect the two wires to the new sensor. Make sure to match the colors. I used shrink tube and line connectors. Once you have the new wires spliced together and protected with either shrink tube or electrical tape, tuck the excess wire out of the way and attach the new sensor. This is easily done by slight pressure on the sensor with the tube in between the clip and sensor. Make sure the wires are tuck out of the way and reassemble the freezer panel, light bulb, and shelves in the reverse order.
Was this instruction helpful to you?
Thank you for voting!