TFX24FLJ General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Thomas from Las Vegas, NV
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
door wouldn't close all the way.
There was what seemed to be a half chewed up washer under the refig. door. The door wasn't closing all the way. DING!! Something was wrong!!
I looked up your schematic for the refrig door and decided what piece might have broken. It was a good guess and the part showed up a few days later.
I wedged up the refrig door to take the tension off the lower bracket. Then, just took off the bracket and replaced the broken door closing cam.
I looked up your schematic for the refrig door and decided what piece might have broken. It was a good guess and the part showed up a few days later.
I wedged up the refrig door to take the tension off the lower bracket. Then, just took off the bracket and replaced the broken door closing cam.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Springfield, MA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Door wouldn't close by itself. Cam part found on floor.
I removed two screws at the top of the door, lifted the door off. I got lucky: the broken cam was the one on the door (easy to remove), not the one on the body of the refrigerator (tough to remove).
There is a shim which was also broken - no way to know that ahead of time. I bent a 5/8" lock washer flat and it served acceptably as a shim.
It would be helpful if PartSelect.com could include with its listing of the cam, the fact that (1) the shim will probably be needed, and (2) there's a very good chance that you'll need TWO of the cams as well.
There is a shim which was also broken - no way to know that ahead of time. I bent a 5/8" lock washer flat and it served acceptably as a shim.
It would be helpful if PartSelect.com could include with its listing of the cam, the fact that (1) the shim will probably be needed, and (2) there's a very good chance that you'll need TWO of the cams as well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Charlotte, NC
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
door did not close automatically
Removed screws holding top door hinge. Lifted the door off bottom hinge. Unscrewed cam from bottom of door. Drilled out rivet holding the second cam in the bottom hinge. Replaced both cams using a flat headed bolt to hold the bottom cam. Dropped door into bottom hinge and replaced top hinge screws. Job done.
Make sure you buy two cams and have a bolt to replace the bottom rivet.
Not a difficult job as long as you have a drill !!!
Make sure you buy two cams and have a bolt to replace the bottom rivet.
Not a difficult job as long as you have a drill !!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lucky from Dacula, GA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator door would not close.
1. I removed the top door hinge.
2. I removed the door and laid it flat.
3. I replaced the cam attached to the bottom of the door. This was very easy.
4. I removed the bottom door hinge and had to remove the brad that held the second cam. This went well as I was able to saw it with a hacksaw.
5. Replaced the second cam with a bolt and nut.
6. Replaced the door and top hinge.
7. Remember to order two cams when you do this repair.
2. I removed the door and laid it flat.
3. I replaced the cam attached to the bottom of the door. This was very easy.
4. I removed the bottom door hinge and had to remove the brad that held the second cam. This went well as I was able to saw it with a hacksaw.
5. Replaced the second cam with a bolt and nut.
6. Replaced the door and top hinge.
7. Remember to order two cams when you do this repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Omaha, NE
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Refrigerator door wasn't self-closing; door hung a little lower than the freezer door
The old plastic door closer cam on bottom of the the door had broken. What was left of it was held on by a hex head screw. There was also a fiber spacer under the cam that was broken. I made a new one out of a piece of aluminum, but cardboard probably would have worked.
Forgot to mention you have to take the door off first--loosen the two screws on the top hinge and lift the door out of the bottom hinge.
I found the self-closing sometimes won't work well until there is some weight in the door.
Forgot to mention you have to take the door off first--loosen the two screws on the top hinge and lift the door out of the bottom hinge.
I found the self-closing sometimes won't work well until there is some weight in the door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Zelienople, PA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Plastic door closer failed
I Supported the door with wood blocks. Then used a socket wrench to remove both parts of the lower hinge. I had purchased 2 of these plastic closers as recommended. One of them must be cut off with a Dremel Tool or small grinder. A small bolt and nut replaces the rivet that was cut off. Reinstall it just as it was removed. Job complete.
Parts were delivered on time, web site instructions were excellent. I highly recommend PartSelect.com
Parts were delivered on time, web site instructions were excellent. I highly recommend PartSelect.com
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Almont, MI
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator door not closing right
i'm glad I read this forum before ordering the part because you need two of the door cams. They're sandwiched together on the lower hinge.
I removed the top door hinge, lifted the door off from the lower hinge and layed it on the counter.
I then removed the lower hinge using a nut driver.
I had to grind the rivot head off that holds the door cam onto the hinge and use a nut & bolt to replace
the rivot.
I removed the top door hinge, lifted the door off from the lower hinge and layed it on the counter.
I then removed the lower hinge using a nut driver.
I had to grind the rivot head off that holds the door cam onto the hinge and use a nut & bolt to replace
the rivot.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Cheyenne, WY
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Right side door (refigerator) would not stay closed
completely removed door, then replaced worn-out cam on bottom of door-simple enough; then removed hinge from bottom of refrigerator; removing old cam required drilling out the rivet that fastened cam to hinge; secured new cam to hinge with small machine screw and nut. This procedure is relatively easy but does require minor mechanical ability and having a small drill and bit set. However, replacing the two cams totally fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carmine from Millington, NJ
- Parts Used:
- WR17X2740
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Replaced corroded auger
Removed front cover, removed rear cover careful to note position of spring assisted parts, used pliers to unscrew auger rod end cap, removed and soaked in Lime Away fixed and movable blades. Reassembled using diagram on website for guidance.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Boulder, CO
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Door would not stay closed
I took the top over off the pivet bracket and used a nut driver to remove the screws on the pivet. Lifted the door off and put on some saw horsess. I revoved the pieces of the old cam on the door by taking out the screw and put the new cam back.
I then drilled out the rivet on the bracket on the door and removed the broken cam. replaced it with the new one and used a screw and nut to replace the rivet. Put the door back and works great now.
I then drilled out the rivet on the bracket on the door and removed the broken cam. replaced it with the new one and used a screw and nut to replace the rivet. Put the door back and works great now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nghia from San Jose, CA
- Parts Used:
- WR17X2740
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Replace Rusty Item
Before disassembling the parts need to replace, I use my digital camera to get all the different angle of the item so I have the full reference to asswmble the new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Washington, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Fridge door did no close and was out of alignment
Followed previous poster's steps. Replacement of door closing cams took 35 minutes. Make sure you buy 2 cams for each door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Hudson, NC
- Parts Used:
- WR72X215
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Drawer slide Broke
Replaced the Drawer Slide, Part was not an exact fit. New part was taller than the original. The Glass shelf that sets on top of the slide now sets at an angle.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Chesterfield, MI
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Refrigerator door would not close by itself - would stay open when you thought it was closed
1st: Order (2) closing cams! One for the hinge pin / bracket and one for the bottom of the door.
The closing cam on the door was where the Dremel type tool is required, since you have to grind the head off of a factory rivet.
I installed the cam with an aluminum pop rivet.
Next, remove the bracket on the bottom of the door with sockets and install the second closing cam.
Re-attach the top door hinge pin and align visually; tighen all bolts. Job finished, but more important , my wife is not nagging me about the repair that I put off for over a year!!!!
The closing cam on the door was where the Dremel type tool is required, since you have to grind the head off of a factory rivet.
I installed the cam with an aluminum pop rivet.
Next, remove the bracket on the bottom of the door with sockets and install the second closing cam.
Re-attach the top door hinge pin and align visually; tighen all bolts. Job finished, but more important , my wife is not nagging me about the repair that I put off for over a year!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Largo, FL
- Parts Used:
- WR72X215
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The drawer rail broke
I removed the crisper drawer, glass shelf and the meat drawer. I then removed the two screws that hold the drawer rail to the refrigerator. Installed the new drawer rail and glass shelf. However the back deflector that directs cold air into the upper drawer does not fit properly on the new drawer rail. I just had to rest the deflector on top of the rail.
Was this instruction helpful to you?
Thank you for voting!