door wouldn't close all the way.
There was what seemed to be a half chewed up washer under the refig. door. The door wasn't closing all the way. DING!! Something was wrong!!
I looked up your schematic for the refrig door and decided what piece might have broken. It was a good guess and the part showed up a few days later.
I wedged up the refrig door to take the tension off the lower bracket. Then, just took off the bracket and replaced the broken door closing cam.
I looked up your schematic for the refrig door and decided what piece might have broken. It was a good guess and the part showed up a few days later.
I wedged up the refrig door to take the tension off the lower bracket. Then, just took off the bracket and replaced the broken door closing cam.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carmine from Millington, NJ
- Parts Used:
- WR17X2740
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Replaced corroded auger
Removed front cover, removed rear cover careful to note position of spring assisted parts, used pliers to unscrew auger rod end cap, removed and soaked in Lime Away fixed and movable blades. Reassembled using diagram on website for guidance.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Springfield, MA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Door wouldn't close by itself. Cam part found on floor.
I removed two screws at the top of the door, lifted the door off. I got lucky: the broken cam was the one on the door (easy to remove), not the one on the body of the refrigerator (tough to remove).
There is a shim which was also broken - no way to know that ahead of time. I bent a 5/8" lock washer flat and it served acceptably as a shim.
It would be helpful if PartSelect.com could include with its listing of the cam, the fact that (1) the shim will probably be needed, and (2) there's a very good chance that you'll need TWO of the cams as well.
There is a shim which was also broken - no way to know that ahead of time. I bent a 5/8" lock washer flat and it served acceptably as a shim.
It would be helpful if PartSelect.com could include with its listing of the cam, the fact that (1) the shim will probably be needed, and (2) there's a very good chance that you'll need TWO of the cams as well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Woodbury, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator door would not close properly
I first removed all of the door contents. I then removed the door from its mountings by removing two screws at the bottom bracket. With the door lying on the floor I then removed the two screws holding the door cam assembly in place. I inserted the new door cam, then reversed the process replacing the four screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eugene from Macedon, NY
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
door dropped when opening and wouldn't stay partially opened
removed top plate and raised the door off. I removed the L bracket from the fridge then noticed the part was rivited onto the L bracket. I cut the rivit and replaced the cam and used a small bolt and nut to sdecure it. Replaced the L bracket, the door, and the upper support. Only problem was the surprise rivit
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Largo, FL
- Parts Used:
- WR72X215
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The drawer rail broke
I removed the crisper drawer, glass shelf and the meat drawer. I then removed the two screws that hold the drawer rail to the refrigerator. Installed the new drawer rail and glass shelf. However the back deflector that directs cold air into the upper drawer does not fit properly on the new drawer rail. I just had to rest the deflector on top of the rail.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gregory from ellerslie, MD
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
door was uneven and wouldn't close tight
removed the door, installed the cam riser, and reattached the door. It took longer to remove the contents in the door than it did to install the cam riser.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles M from Concord, NC
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Door Closing Cam broke
The bottom of the door was 5 " off the floor. A 2x4 block and a 4x4 block were pushed under the door and supported it while the water line was disconnected the hinge removed and the cam replaced. It was a simple fix and reading other people's experience made the repair so much easier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Darien, IL
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Door won't close
This my second time to do it after 8 years. Took 10 minutes.
1 Remove all the contents on the side door
2 Remove the 2 bolts on top connecting the door to the refrigarator
3 Lift and remove the door up and put it the side
4 Clean and remove the old door closing cam put the new one
5 Door ref is fixed
1 Remove all the contents on the side door
2 Remove the 2 bolts on top connecting the door to the refrigarator
3 Lift and remove the door up and put it the side
4 Clean and remove the old door closing cam put the new one
5 Door ref is fixed
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Burmingham, AL
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Problem closing door, would not shut easily.
My wife and I gave an old, but really good refergerator to our son (a Major in the Army). Upon taking it into his house he had to remove the doors of the refergerator. While he put the doors he lost the "cam" for the door, making if difficult to close (actually had to lift the door up and then close it). I ordered the replacement part, and unless I am mistaken, it arrived the same day. I still cannot figure out how this happened, but it was great!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Hudson, NC
- Parts Used:
- WR72X215
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Drawer slide Broke
Replaced the Drawer Slide, Part was not an exact fit. New part was taller than the original. The Glass shelf that sets on top of the slide now sets at an angle.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from San Antonio, TX
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Door would not stay open
Removed the top cover using a Phillips screw driver to access the top 2 screws holding the bracket. Once the bracket was removed, lifted the door off the bottom hinge. Replaced the door closing cam, replaced shims and screws. Placed the door back on the bottom hinge, inserted the top bracket and secured.
This was the ultimate resolution to the problem. The problem I encountered was getting all of the correct parts. It took me 3 tries to finally identify and receive the parts needed to make the repairs. Using Part Select made it easy because they had the parts I needed. My 3 tries were partly my error and does not reflect on Part Select. I would recommend others use Part Select when choosing their replacement parts.
This was the ultimate resolution to the problem. The problem I encountered was getting all of the correct parts. It took me 3 tries to finally identify and receive the parts needed to make the repairs. Using Part Select made it easy because they had the parts I needed. My 3 tries were partly my error and does not reflect on Part Select. I would recommend others use Part Select when choosing their replacement parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Chesterfield, MI
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
Refrigerator door would not close by itself - would stay open when you thought it was closed
1st: Order (2) closing cams! One for the hinge pin / bracket and one for the bottom of the door.
The closing cam on the door was where the Dremel type tool is required, since you have to grind the head off of a factory rivet.
I installed the cam with an aluminum pop rivet.
Next, remove the bracket on the bottom of the door with sockets and install the second closing cam.
Re-attach the top door hinge pin and align visually; tighen all bolts. Job finished, but more important , my wife is not nagging me about the repair that I put off for over a year!!!!
The closing cam on the door was where the Dremel type tool is required, since you have to grind the head off of a factory rivet.
I installed the cam with an aluminum pop rivet.
Next, remove the bracket on the bottom of the door with sockets and install the second closing cam.
Re-attach the top door hinge pin and align visually; tighen all bolts. Job finished, but more important , my wife is not nagging me about the repair that I put off for over a year!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Nghia from San Jose, CA
- Parts Used:
- WR17X2740
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Replace Rusty Item
Before disassembling the parts need to replace, I use my digital camera to get all the different angle of the item so I have the full reference to asswmble the new one
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robin from North Plainfield, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
Door Cam And Cam On Refridgerator Were Damaged
I did not realize I needed 2 cams to complete repair. Door cam was riveted in. I had to drill out rivet and replace with nut and bolt. Otherwise it went quite sommothly. At first I just replaced the cam on bottom of refridgerator but door was not quite right when closing. Further inspection showed the door had the other half of cam that also needed replacement. Needed 2 orders. Paid for 2 shippings.