GSH25KGMCBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- David from Woodland Hills, CA
- Parts Used:
- WR17X11497
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
A piece of the crusher cover broke off into the ice bin
I removed the ice bin, removed the metal rod off the bottom, unscrewed all screws holding things together and then carefully pried the crusher assembly out of the ice bin. I made the mistake of doing it when the bin was still frozen and ended up cracking it where the "clips" from the crusher are inserted. It was much easier after the bin warmed up.
Replaced and put everything back together.
Replaced and put everything back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Meridian, MS
- Parts Used:
- WR17X11168
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
Icemaker supply hose leaking at freezer entrance
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- D from ZELLWOOD, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from cleburne, TX
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jamison from Heltonville, IN
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sherry from Auburn Hills, MI
- Parts Used:
- WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Williamsburg, VA
- Parts Used:
- WR17X22070
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
No longer needed water filters
Your website was very easy to use and the product shipped very promptly. It was great experience. Thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Republican City, NE
- Parts Used:
- WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker door failed to close letting ice melt
Removed the front panel on the door that has the ice maker controls. Removed the screws and parts. Reassembled the parts and it works better than new. Ice door closes firmly and holds tight.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jason` from Colchester, CT
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from DOWS, IA
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer Cold Refrigerator warm
The defrost heater failed. The coils frosted completely over so no airflow to the fridge. Step 1. Empty the freezer. Ice maker and top shelf can stay. Remove power, pull plug or open breaker. Step 2. Remove shelves and bottom food drawer. Step 3. Remove bottom food drawer rails. 2 phillips screws on each side. Step 4. Remove back panel, 2 screws at the top. Work panel out. Note there may be a green ground wire hook on it at the top. This will expose the heater and the cooling coils. The heater is at the bottom of the cooling coils and is the width of the coils. Step 5. There will be 2 wires, one on each end, and two phillips screws holding it in. Wires pull straight out. Note which way the heater is installed and remove the 2 screws. Step 6. Assemble in reverse order. Be very careful with the heater. It is in a glass tube and is very easy to break.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- calvin from annapolis, MD
- Parts Used:
- WR62X10055, WR17X11653, WR17X10706, WR02X10585
- Difficulty Level:
- Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cristina from Los Angeles, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sheila from Robeline, LA
- Parts Used:
- WR02X11941, WR62X23154
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
ice auger drive stripped out, solenoid burned out
removed ice tray, removed drive unit. removed solenoid and replaced, screwed on auger drive. reinstalled drive assembly. replaced ice tray. job done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Billings, MT
- Parts Used:
- WR17X11267, WR17X11170, WR17X10745
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Melted Dispenser Housing Shield with hair dryer trying to thaw out frozen water line
Pull plastic trim piece off refridgerator door,unclip printed circuit board and remove wires unscrew dispenser housing,and remove. Transfer Ice funnel to new dispenser housing with old spring. Reinstall dispenser housing and printed circuit board.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from Daly City, CA
- Parts Used:
- WR55X10025, WR17X11067
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
Freezer cooling, but freezer fan not operating consistently
My refrigerator's initial problem was as follows:
1. Freezer fan stopped circulating the cooled air. Causing food to thaw at the top of the freezer, and freeze solid at the bottom. Ice in the icemaker thawed.
2. Water dripped from the freezer door gasket when the freezer was in defrost mode & water dispenser would not dispense water.
--FIX (the easy one first..):
2. I removed the inner freezer door panel and found ice filling every void of the freezer door panel-approx 5 lbs of ice dammed in the panel. I thawed the insulation and removed the ice. Also there is a styrofoam insulating surround around the inside of the dispenser panel. The styrofoam had become saturated with water and was freezing, allowing the drinking water tube to freeze, not allowing the refrigerator to dispense water...
THE CAUSE:
2. Overflowing of water from the in-door ice/water dispenser compartment reservoir (just under the grill where your glass sits, when it's dispensing water) was draining into the freezer door panel.
PREVENTION:
2. Check the reservoir more frequently to make sure water does not build up and overflow into the door.
FIX (now the trickier one..)
1. I initially thought it was the main circuit board. I replaced the board. Access is by removing the 3 hex nut screws holding door in place at the rear of the freezer. Disconnect connectors & using a needle nose pliers, squeezed the plastic catches that hold the board in place. Connect the new board (being careful not to touch the components or traces on the board) to the connectors, then snap into place using the white plastic catches.
Close everything up.
NOTE: This may, may not have contributed to the problem, but my refrigerator light went out. I replaced it with a small flouresent bulb. That bulb did not last, and became inop. Shortly afterward, the freezer started malfunctioning. I replaced the board, and the freezer was still somewhat intermittent. I replaced the bulb with an appliance 60 watt. The freezer has been perfect since...
Note: I first ordered the main circuit board, when that didn't immediately fix the problem, I ordered the above parts. I did not need the parts and am returning them. The web page is forcing me to select at least one of the parts needed for the repair, when I used neither.
1. Freezer fan stopped circulating the cooled air. Causing food to thaw at the top of the freezer, and freeze solid at the bottom. Ice in the icemaker thawed.
2. Water dripped from the freezer door gasket when the freezer was in defrost mode & water dispenser would not dispense water.
--FIX (the easy one first..):
2. I removed the inner freezer door panel and found ice filling every void of the freezer door panel-approx 5 lbs of ice dammed in the panel. I thawed the insulation and removed the ice. Also there is a styrofoam insulating surround around the inside of the dispenser panel. The styrofoam had become saturated with water and was freezing, allowing the drinking water tube to freeze, not allowing the refrigerator to dispense water...
THE CAUSE:
2. Overflowing of water from the in-door ice/water dispenser compartment reservoir (just under the grill where your glass sits, when it's dispensing water) was draining into the freezer door panel.
PREVENTION:
2. Check the reservoir more frequently to make sure water does not build up and overflow into the door.
FIX (now the trickier one..)
1. I initially thought it was the main circuit board. I replaced the board. Access is by removing the 3 hex nut screws holding door in place at the rear of the freezer. Disconnect connectors & using a needle nose pliers, squeezed the plastic catches that hold the board in place. Connect the new board (being careful not to touch the components or traces on the board) to the connectors, then snap into place using the white plastic catches.
Close everything up.
NOTE: This may, may not have contributed to the problem, but my refrigerator light went out. I replaced it with a small flouresent bulb. That bulb did not last, and became inop. Shortly afterward, the freezer started malfunctioning. I replaced the board, and the freezer was still somewhat intermittent. I replaced the bulb with an appliance 60 watt. The freezer has been perfect since...
Note: I first ordered the main circuit board, when that didn't immediately fix the problem, I ordered the above parts. I did not need the parts and am returning them. The web page is forcing me to select at least one of the parts needed for the repair, when I used neither.
Was this instruction helpful to you?
Thank you for voting!