- Customer:
- Thomas from Las Vegas, NV
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
door wouldn't close all the way.
There was what seemed to be a half chewed up washer under the refig. door. The door wasn't closing all the way. DING!! Something was wrong!!
I looked up your schematic for the refrig door and decided what piece might have broken. It was a good guess and the part showed up a few days later.
I wedged up the refrig door to take the tension off the lower bracket. Then, just took off the bracket and replaced the broken door closing cam.
I looked up your schematic for the refrig door and decided what piece might have broken. It was a good guess and the part showed up a few days later.
I wedged up the refrig door to take the tension off the lower bracket. Then, just took off the bracket and replaced the broken door closing cam.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Timothy from Rockville, MD
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers, Socket set
Refrigerator door wouldn't close properly due to broken cams.
Thanks to the stories on PartSelect my wife and I knew what to expect. The biggest hassle was sawing off the rivet that's on the hinge on the refrigerator (my wife volunteered for that job). When we got everything back together the door worked a lot better, but still wouldn't close without a little push. In frustration and running out of time, we put the stuff back inside the refrigerator door and that did the trick! The weight was enough to allow the door to close on its own.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Cheyenne, WY
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Right side door (refigerator) would not stay closed
completely removed door, then replaced worn-out cam on bottom of door-simple enough; then removed hinge from bottom of refrigerator; removing old cam required drilling out the rivet that fastened cam to hinge; secured new cam to hinge with small machine screw and nut. This procedure is relatively easy but does require minor mechanical ability and having a small drill and bit set. However, replacing the two cams totally fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Omaha, NE
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Refrigerator door wasn't self-closing; door hung a little lower than the freezer door
The old plastic door closer cam on bottom of the the door had broken. What was left of it was held on by a hex head screw. There was also a fiber spacer under the cam that was broken. I made a new one out of a piece of aluminum, but cardboard probably would have worked.
Forgot to mention you have to take the door off first--loosen the two screws on the top hinge and lift the door out of the bottom hinge.
I found the self-closing sometimes won't work well until there is some weight in the door.
Forgot to mention you have to take the door off first--loosen the two screws on the top hinge and lift the door out of the bottom hinge.
I found the self-closing sometimes won't work well until there is some weight in the door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Zelienople, PA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Plastic door closer failed
I Supported the door with wood blocks. Then used a socket wrench to remove both parts of the lower hinge. I had purchased 2 of these plastic closers as recommended. One of them must be cut off with a Dremel Tool or small grinder. A small bolt and nut replaces the rivet that was cut off. Reinstall it just as it was removed. Job complete.
Parts were delivered on time, web site instructions were excellent. I highly recommend PartSelect.com
Parts were delivered on time, web site instructions were excellent. I highly recommend PartSelect.com
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Boulder, CO
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Door would not stay closed
I took the top over off the pivet bracket and used a nut driver to remove the screws on the pivet. Lifted the door off and put on some saw horsess. I revoved the pieces of the old cam on the door by taking out the screw and put the new cam back.
I then drilled out the rivet on the bracket on the door and removed the broken cam. replaced it with the new one and used a screw and nut to replace the rivet. Put the door back and works great now.
I then drilled out the rivet on the bracket on the door and removed the broken cam. replaced it with the new one and used a screw and nut to replace the rivet. Put the door back and works great now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Woodbury, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator door would not close properly
I first removed all of the door contents. I then removed the door from its mountings by removing two screws at the bottom bracket. With the door lying on the floor I then removed the two screws holding the door cam assembly in place. I inserted the new door cam, then reversed the process replacing the four screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Almont, MI
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator door not closing right
i'm glad I read this forum before ordering the part because you need two of the door cams. They're sandwiched together on the lower hinge.
I removed the top door hinge, lifted the door off from the lower hinge and layed it on the counter.
I then removed the lower hinge using a nut driver.
I had to grind the rivot head off that holds the door cam onto the hinge and use a nut & bolt to replace
the rivot.
I removed the top door hinge, lifted the door off from the lower hinge and layed it on the counter.
I then removed the lower hinge using a nut driver.
I had to grind the rivot head off that holds the door cam onto the hinge and use a nut & bolt to replace
the rivot.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robin from North Plainfield, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
Door Cam And Cam On Refridgerator Were Damaged
I did not realize I needed 2 cams to complete repair. Door cam was riveted in. I had to drill out rivet and replace with nut and bolt. Otherwise it went quite sommothly. At first I just replaced the cam on bottom of refridgerator but door was not quite right when closing. Further inspection showed the door had the other half of cam that also needed replacement. Needed 2 orders. Paid for 2 shippings.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- vincent from mahwah, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
door was not closing properly
Your vidio was Brilliant !!i just followed your instructions
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Wooster, OH
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Door closing cam (made of Plastic) just wore out with age and broke in half
Took the door contents out and put them on the counter, took the door off the hinges by unscrewing the 2 screws on the top of the Fridge and lifting the door off the hinge onthe bottom. Then laid down the Fridge on the kitchen floor and replaced the Door Closing Cam, keeping in mind the order of the 3 shims and other things on the bottom of the door. Simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles M from Concord, NC
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Door Closing Cam broke
The bottom of the door was 5 " off the floor. A 2x4 block and a 4x4 block were pushed under the door and supported it while the water line was disconnected the hinge removed and the cam replaced. It was a simple fix and reading other people's experience made the repair so much easier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gregory from ellerslie, MD
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
door was uneven and wouldn't close tight
removed the door, installed the cam riser, and reattached the door. It took longer to remove the contents in the door than it did to install the cam riser.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Washington, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Fridge door did no close and was out of alignment
Followed previous poster's steps. Replacement of door closing cams took 35 minutes. Make sure you buy 2 cams for each door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from San Antonio, TX
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Door would not stay open
Removed the top cover using a Phillips screw driver to access the top 2 screws holding the bracket. Once the bracket was removed, lifted the door off the bottom hinge. Replaced the door closing cam, replaced shims and screws. Placed the door back on the bottom hinge, inserted the top bracket and secured.
This was the ultimate resolution to the problem. The problem I encountered was getting all of the correct parts. It took me 3 tries to finally identify and receive the parts needed to make the repairs. Using Part Select made it easy because they had the parts I needed. My 3 tries were partly my error and does not reflect on Part Select. I would recommend others use Part Select when choosing their replacement parts.
This was the ultimate resolution to the problem. The problem I encountered was getting all of the correct parts. It took me 3 tries to finally identify and receive the parts needed to make the repairs. Using Part Select made it easy because they had the parts I needed. My 3 tries were partly my error and does not reflect on Part Select. I would recommend others use Part Select when choosing their replacement parts.
Was this instruction helpful to you?