Robert from BOULDER, CO
Parts Used:
WR60X31522, WR60X46086
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Freezer was wet and there was no air coming out of the freezer fan. Unit was very noisy too.
The video that was attached to the part order was good, but not exactly the same as my unit. One thing I recommend is that you cover up the drain below the evaporator coil with a piece of paper and tape it down, because as I was putting the motor back I dropped a screw and it fell down the drain. So I had to go buy a new screw.
Give the cost of a repair man coming to fix a refrigerator that cost only $450 to begin with, doing this repair was well worth my time. (But I also had another refrigerator to move things to and could take my time and wait while they replaced the faulty part they shipped me.)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from SIOUX FALLS, SD
Parts Used:
WR60X31522, WR60X46086, WR02X12149, WR02X12008
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
There was frequently a loud buzzing sound that would come from the freezer.
I wouldn't have tried it without the excellent YouTube video that gave step-by-step instructions! I set up a laptop next to the refrigerator and watched each step then did it myself.

The instructions were very detailed and all of the parts looked exactly like what I was seeing. The only difference was that I didn't need to remove the floor of the freezer to get to the fan motor.

I bought the fan motor, grommets (2), compression ring and fan blade because I wasn't sure which part was causing the problem, and figured that as long as I was in there I might as well put in all new parts.

As it turned out, I did not need the compression ring, because the new fan blade came with a compression ring on it. This was different from what was shown in the video.

Since doing the repair the freezer is now as quiet as it should be, which is a great relief. The project and the money spent were more than worth it. It was great not having to pay a repair man to do the work!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from New York, NY
Parts Used:
WR50X10071
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer is too hot
Open the freezer panel which attached with screwws and locate the defrost thermmostate behind the back pannel. Cut off the old thermostat wires and connect the new wires.
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jose A from WEST PALM BCH, FL
Parts Used:
WR09X20002
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Was getting too cold
Was only two screws after that carefully took the part away unplugging the wires at the same time was plugging in to the new part and was done after 5 or 7 min
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marcella from SPRINGFIELD, MA
Parts Used:
WR17X11662
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Shelf was cracked on both sides
I first washed old shelf to make sure glass will easily slip out. Installed old glass and replaced.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from UNION CITY, NJ
Parts Used:
WR17X11889
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Fixed shelf was cracked.
I popped out the old plastic shelf and slid in the new one. It was self explanatory and took less than one minute with no tools.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MaryLou from Levittown, NY
Parts Used:
WR60X10207
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Noise in the back of freezer
I must thank yo for sending the fan so fast. If I ever have to deal with any appliance again, you are first on my list.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paypal_shipping_address from Ripon, CA
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Herbert from POCONO LAKE, PA
Parts Used:
WR60X10168, WR02X10098
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
the condenser fan motor was intermittently verynoisy. obvious sign of a (possibly imminent) failure
1 unplug the appliance
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter M. from Lincoln Park, NJ
Parts Used:
WR02X10540
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Duryea, PA
Parts Used:
WR17X11889
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
cracked shelf
took old one out replace new one less then minute
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jack from homestead, FL
Parts Used:
WR60X31522
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Fridge making LOUD humming sound.
Started removing screws until I got to the fan (it's easy). Then just took out the old fan and put the new one back in the same way. The only challenging part was putting the clamp back on the fan, but I finally got it. The fridge is finally quiet and we can sleep again! PartSelect made it really easy and they were incredibly fast. Thanks!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jodi from Benton Harbor, MI
Parts Used:
WR23X37285
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jacky from Richland, GA
Parts Used:
WR60X10207, WR60X10168
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Old fan motor was knocking and not running well
Watched your repair video online. appeared very simple and straight forward. Order the parts in question. They were shipped quickly. Once parts in hand watched video again and then installed new motor and blade in less than ten minutes. Plug power back in and and new part works perfectly. Thanks for helping make it an easy process. J. Smith
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ella from RODESSA, LA
Parts Used:
WR17X11890
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
None
Just place the shelf door bar in slot and push in place gentle.