- Eric from NEW YORK, NY
- Parts Used:
- WR02X10520
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Noisy refrigerator
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Kalispell, MT
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Noisey evap motor
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and spliced them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
Peter
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jake from Brainerd, MN
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Ice maker inlet tube was freezing up, and eventually the icemaker overfilled and completely froze up
After lots of research online, i narrowed my problem down to be the double outlet water valve, behind the fridge. My biggest problem was getting the refridgerator out of its spot, but after that it was pretty simple to change. I took the cover off the bottom, in the back of the fridge, then i removed the inlet waterline (after i turned off the water supply to the fridge). After that i removed the screw that holds the valve to the framework. Now i pulled off the two other waterlines from the old valve and moved them, one at a time, over to the new valve, along with the wire harness. The rest of the instalation was reverse order. Simple fix that im glad i didn't pay an expert to do!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from ORANGE, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony from Carmel, IN
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
No water from the dispenser
I pulled-out & unplugged the refrigerator. Removed the screws to gain access through the lower back panel. The water valve is on the left side as I face the back of the fridge. It has one screw holding it to the frame of the fridge. Once it is free, the main water hose is unscrewed and the two out-let lines were pulled-out. If your valve was not ruined prior to this, it is ruined now, as the lines will not re-seat. Then everything is done in reverse order. I did cut 1/2 inch off of the two lines so that they reseat into the new valve. Just push into the valve and they are good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bob J from Platte City, MO
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Water not dispensing
Background: My refrigerator was part of the class action law suit back in 2006. As a result both doors, the auger in the ice maker and a heating element in the freezer were all replaced.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- nancy from Mt. Washington, KY
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
Was not getting water to the door.
Moved refrigerator out from wall, unplugged from electric, removed plate at bottom back with 1/4 nut driver, turned incoming water valve off, disconnected water line from water valve on refrigerator, removed mounting screw, remove water lines from valve and electrical plugs, set old valve aside and replace with new valve, reconnecting water lines and electrical plugs then remount bracket, reconnect water line from source, open water valve and check for leaks, replugged refrigerator and depressed the door button to check to see if working. It worked and there was not any leaks. Replaced back plate and placed refrigerator against wall. Job completed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Summer feild, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
cold water dispenser would not stop running
Turn off the water.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chip from Mandeville, LA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Keller, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Folsom, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clyde from RIALTO, CA
- Parts Used:
- WR60X24484, WR60X10209
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Tampa, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water not dispensing
Moved refrigerator forward, this allowed me to work on the back panel. Unplugged the refrigerator power cord. Released all 6 screws, removed panel then release an additional screw that was holding the water valve and the two (red & blue) connectors. Then installed the new part in reverse steps. Plug the unit and job well done. I had purchase the water filter already after several minutes push for water from the dispensing front part of the refrigerator and good to go, later in the evening we notice the ice maker working fine and producing ice. Thank you parts select.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from FARMINGVILLE, NY
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refrigerator not cold
removed freezer door / shelf /ice maker pulled back panel off and removed fan
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Helotes, TX
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
Ice build up behind ice maker ,water chute frozen up
Unplugged ref.,turnned water off at wall and drained, removed back cover on lower part of ref. then removed screw holding water valve,unplugged both wires from unit,pulled the 3 water lines off,1 I had to cut, would not release,got new water valve,push 3 water lines in place,attached the 2 wires in place and screwed unit back on ref.and replaced back cover on ref. Then I got a hair dryer and thawed all ice that had built up behind and under ice maker in freezer,cleaned that mess up,turned water back on plugged in ref. All good ,repaired problem,old water valve was bad.
Was this instruction helpful to you?
Thank you for voting!