The bottom shelf that covers the crisper drawers was cracked.
This was so easy. Got the model number off the refrigerator door. Internet searched and found this website. Ordered the part. Waited maybe 3-4 days for it to arrive. Opened the box, open refrigerator door remove old broken part, install new part and reinstall the drawers. Piece of cake!! So glad I didn’t have to replace a perfectly good refrigerator. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from DOUGLASVILLE, GA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Fridge never cuts off.freeze everything inside of fridge.
To remove the temp sensor.2 Phillip head screws not remove the cover inside fridge .the temp control knob cover.removed that and unplugged switch.installed new switch.reinstalled cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Boyd from Blaine, WA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Could not adjust temperature
Replaced temp controller
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mackenzie from Williston, ND
- Parts Used:
- WR09X20002
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Compressor would randomly not turn on. Fridge too warm sometimes.
Replace temperature control. That fixed it. Also, removed plastic bag obstructing air vent in freezer which added performance. Fridge works good now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Scott from NAPLES, FL
- Parts Used:
- WR24X10228
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Socket set
Replace the door gasket on the freezer door of my top-freezer refrigerator
Removed the door by removing the two screws holding it on. Do not try to do this repair with the door attached. Easily removed the old gasket. Getting the new one on the door was EXTREMELY difficult. I couldn't do it. After 90 minutes, I gave up and called my appliance repairman. When he arrived, he and I worked together to get the new gasket on the door. It took 2 sets of hands to do this. It still took us about 40 minutes. My repairman had a few choice words about the design of the system holding the gasket on the door. Ditto for me. So the cost of my repair was doubled because I had to pay the repairman to help me attach the new gasket. I should have just bought a new fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- neal j from COLUMBIA, SC
- Parts Used:
- WR24X10236
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
gasket was not easily fitted
I did not do the repair but observed a friend trying to replace gasket in refrigerator. It was a very difficult procedure. He works as a handyman so he knew what he was doing and had to manually fit gasket with some help with a hammer. Gasket did not go in easy and had to be forced to fit until job completed/
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- denis from freedom, NH
- Parts Used:
- WR60X203
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
was not defrosting
first i removed all the screws inside the freezer compartment took out theback and bottom to get to the evap motor,unpluged the wires and removed the evap motor ,removed the fan from old unit and put it on the new unit them mounted it to the back wall of the fridge,,, and put back top and bottom
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Harrisburg, PA
- Parts Used:
- WR32X10398
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Old cover was cracked and needed replaced
The repair only required removing nthe old cover and installing the new one. What I was really surprised about is the time for delevery. I ordered the part on Friday morning around 11 AM and it was delevered by Fed Ex at 8:30 AM on Saturday morning. I am not sure how many locations they have, but this must have been close to Harrisburg, Pa.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- glenn from la harpe, KS
- Parts Used:
- WR60X203
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
drain freezing up found cond fan not working
Cleaned oh t freezer removed floor. Removed back inside wall removed and replaced fan and put back removed parts
L
L
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wanda from HOUSTON, TX
- Parts Used:
- WR32X10398
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broken crisper drawer cover
After removing all items from the broken top, I removed both drawers and crisper top. I then slid the new top in place and replaced the drawers which easily slid into the grooves in the underside of the top.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from FLUSHING, NY
- Parts Used:
- WR60X10168
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The freezer just cool but could not freeze the water and the front of door is quite hot to touch.
First I observe that the compressor motor is running since the freezer is cooling. The purchase of the condenser fan is initiated and when the part arrive it is just easy to reinstall the replacement condenser fan.
The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.
The refrigerator as of now is running in perfect condition!
The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.
The refrigerator as of now is running in perfect condition!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jose A from WEST PALM BCH, FL
- Parts Used:
- WR09X20002
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Was getting too cold
Was only two screws after that carefully took the part away unplugging the wires at the same time was plugging in to the new part and was done after 5 or 7 min
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from HAYDEN, CO
- Parts Used:
- WR32X10398, WR71X10378
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Crisper Drawer Cover was broken, and i wanted to add a third shelf for my garage fridge
I slid the old crisper drawer cover out, and slid the new one in. Then I respaced the other shelves, making room for the third shelf, and put the new shelf in. Apart from the time it took me to unpack the boxes these parts came in, and to remove my groceries from the fridge, the "repair" itself took all of about 90 seconds.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Herbert from POCONO LAKE, PA
- Parts Used:
- WR60X10168, WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
the condenser fan motor was intermittently verynoisy. obvious sign of a (possibly imminent) failure
1 unplug the appliance
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor