Models > GTS22KBPARBB > Instructions

GTS22KBPARBB General Electric Refrigerator - Instructions

Jump to:

All Instructions for the GTS22KBPARBB
91 - 105 of 253
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Stephanie from KEARNY, NJ
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light was flicking
It was way to ez to install only a couple of minutes that's it
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ted from SANDWICH, IL
Parts Used:
WR23X37285
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken light switch
took a little more effort than the video show to remove old module and replace new. Works fine now.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Louis from LEAGUE CITY, TX
Parts Used:
40A15
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Change bulb
Easy
3 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kent from Bartlesville, OK
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mahvash from Gold Canyon, AZ
Parts Used:
WR50X10068
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Refridgerator warm, some ice buildup apparent in freezer
Find online diagram of freezer section for reference. Disconnect power, remove evap cover plate (214) by removing one of the drawer guide rails.

As evidence of your problem, you might see a giant block of ice built up around the coil. Let this defrost this before continuing.

Find THERMOSTAT DEFROST (24) sensor and clip connecting wires. Match replacement sensor wires by color. Twist and solder wires; or wire-nuts and twisting alone might be okay. If not soldering, seal the wire-nuts connections from moister with a good sizeable piece of duct tape. Make sure your wires are out of the way and not left dangling on the evap heater coil, where they could melt.

Suggest concurrent replacement of evap fan motor if this has not already been done in the past.. This become noisy with age and damage from the ice build up seems to have made mine worse.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Patrick from Punta Gorda, FL
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Rear of freezer all iced up would not defrost
first removed two srews removed rear panel hair dryer to melt ice (took 30 minutes) cut two wires to thermostat spliced onto new part clipped it onto tube -done replace rear panel and 2 screws. very easy job after reading other letters and their experience -saved myself $500.00
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rafael from New Haven, CT
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
ice on the frezer compartment
turn off the refrigerator,then open the cover and saw lot of ice. then get a hair dryer blower and blow a heat to melt the ice. cut the thermostat defrost.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from Eugene, OR
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The door activated light switch was missing.
Pulled the two wires out from the access hole in the lower part of the refrigerator. Put them in the spade connectors on the new switch, and pushed the switch into place.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Patricia from Sylva, NC
Parts Used:
WR23X37285
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Bad switch for door prevented interior light from coming on
Just as your video described, although due to the age of the fridge, it took a bit longer to remove the defective switch. Your video made this so simple, I can't imagine why we lived with a dark fridge for so long! I was ready to buy a whole new fridge, as repairmen are often nonexistent for small repairs. I am the biggest fan of your company & it's repair video. THANK YOU SO MUCH
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
richard from cleburne, TX
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
warm, refrigerator/freezer,frozen up
verify the heating element was o.k., found the top of the thermostat popped off,it had water in it,probably froze and came apart,cut the wires to the old thermostat and splice the new ones together,put the cover back on and verify operation
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from Greenbelt, MD
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
defrost problem
I replaced the thermostat. I simply followed the insructions in the video on your website and it was done in about 5-10 minutes.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Montrose, CO
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
Fridge kept getting warmer and frost started building up in Freezer
I ordered the part but my husband had to work out of town for a week. The fridge kept getting warmer, so when the part came I just watched the video on the internet, (bit the bullet) and did the repair just as I saw it done on the video. It was simple and exactly the same as the video. It took a little longer for me because there was a lot of ice built up on the coils, so I used my hair dryer to melt the ice. My refridgerator is working great now.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from Monroe, WA
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Refrigerator hot, freezer normal
Refrigerator was showing actual temperature of 80 deg, freezer was about 3 deg high. (house temp was 65 at the time) Defrost heater seemed like the only component able to heat that much, so the defrost thermostat seemed like the likely culprit. I followed the installation directions in the video, and the fridge has been fine ever since.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jerome from Knoxville, TN
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Frost buildup causing freezer to warm up
Unplug the refrigerator. Pull all shelves out of the freezer. Remove light bulb shield and light bulb. Remove the two hex head screws on either side of the light bulb. Wiggle out the back wall. It is a tight sqeeze, but can be done. Locate the sensor on the top of the coils. It is held on by a simple clip. Wiggle the sensor and twist a little to take it off. Take wire cutters and cut the two wires into the sensor near the sensor to allow lots of room to splice in the new sensor. Strip about a quarter inch of wires left in the freezer. Use some sort of wire connectors, like twist caps, which will allow you to connect the two wires to the new sensor. Make sure to match the colors. I used shrink tube and line connectors. Once you have the new wires spliced together and protected with either shrink tube or electrical tape, tuck the excess wire out of the way and attach the new sensor. This is easily done by slight pressure on the sensor with the tube in between the clip and sensor. Make sure the wires are tuck out of the way and reassemble the freezer panel, light bulb, and shelves in the reverse order.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from Dana Point, CA
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice melting occasionally, fridge too warm
I watched the online video on how to replace a defrost limiter. It was almost exactly like my situation and made the job seem familiar. It was inexpensive ($8 part)and easy to do.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?