GSE20IETBFBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Edward from SILVER SPRING, MD
- Parts Used:
- WR60X24484, WR60X10209, WR02X10520
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Noise coming from rear of fridge
Remove rear plate. Remove fan bracket. Replace fan gaskets, blade and motor. Replace bracket. Replace rear plate. Very simple. Fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- RICHARD from SPRING HILL, FL
- Parts Used:
- WR17X11505
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Would Not Come Out
Removed tray, threw out ice , removed 3 screws used 2 screw drivers to seperate part & re installed
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Javier from Woodstock, GA
- Parts Used:
- WR17X11170, WR49X10233
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Unit was not dispensing water nor ice.
Removed the plastic frame by pushing to the inside (all 4 sides), removed touch pad by sliding it to my right and disconnected the wires. Removed the four screws that hold the dispensing unit and replaced broken parts. Please note that I also replaced the funnel. Total cost of repair for DIY $30.00, savings by avoiding repair man, priceless.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joseph from HAMPTON, VA
- Parts Used:
- WR01X37886, WR17X11267
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Broken dispenser engager
Pretty easy to repair. Only took a few minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Milford, CT
- Parts Used:
- WR23X21444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Freezer Light switch broke
Your instructions were "spot on"! Pried out broken switch with screwdriver-reinstalled new switch. Very easy! Ordered on line on a Wednesday new part arrived on following Saturday-Great service and will definately use again. Highly recommend PartSelect!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rachel from LUDOWICI, GA
- Parts Used:
- WR50X10068, WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Would not defrost
Replaced defrost thermostat along with temp sensor watched the video on this page simple fix
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- craig from DAYTON, OH
- Parts Used:
- WR29X43994
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broken Auger blade on GE ice bucket / auger assembly for GE side by side refrigerator
No tools required, remove from shipping box, wash, remove old ice bucker/ auger assembly, insert new assembly.
NOTE! The product description of the ice bucket size on the PartSelect website is MISLEADING: it is not 20”L x 14”W and the photo grid is wrong. The actual size for this model is approximately 16”L x 12”W x 11.5”H, plus about 3” for metal rod extending out the back. The photo and description seems to be common across several companies. This is the correct OEM replacement for WR17X12138 and works well.
NOTE! The product description of the ice bucket size on the PartSelect website is MISLEADING: it is not 20”L x 14”W and the photo grid is wrong. The actual size for this model is approximately 16”L x 12”W x 11.5”H, plus about 3” for metal rod extending out the back. The photo and description seems to be common across several companies. This is the correct OEM replacement for WR17X12138 and works well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Bean Station, TN
- Parts Used:
- WR17X11497, WR17X23192
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice falling in floor instead of glass and building up inside of freezer door
First I removed ice bucket and emptied. I then removed screws that held the covers in place. Next I removed the snapring that held the auger in the covers and removed auger assembly. Replaced both covers and reassembled.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Kalispell, MT
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Noisey evap motor
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and spliced them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
Peter
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- SUE from PORTAGE, WI
- Parts Used:
- WR17X23192, WR29X43990
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Ice auger was damaged
I am 80 years old, female. Repair was a challenge but I was determined as my son said Mom you can do it. The video was wonderful. and I did a lot of rewinding etc. Hardest part was taking apart.. screws tough. All in all not bad. I don't want to do it for a living though!!!!! Ice is now dispensing!!!!!!!!!!!!!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from NEW YORK, NY
- Parts Used:
- WR02X10520
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Noisy refrigerator
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from ZIONSVILLE, PA
- Parts Used:
- WR17X11168
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
water line (from the PS304374 Dual Inlet Water Valve) to the ice maker was craked and leaking
1. Removed the back panel of the fridge to get access to the inlet water valve.
2. Removed black poly water line from valve (pull back on white ring where line is attached and pull the line out)
3. Removed the inlet tube from top-back of fridge (where it goes into the ice make). use putty knife to get under the sticky white gasket beneath the black oval housing and pull the tube out form the back of the fridge.
4. Replace the water line with new part taking care to properly seat the line into the the bottom water valve and pushing the water tube into the hole for the ice maker.
Note: Be sure to take off the protective covering from the white - sticky grommet and push to adhere to metal on fridge.
to be safe - use a bit of clear silicone chaulking round the perimeter of the grommet and push to tighly bond the water inlet tube to the fridge.
The reason for this - is that if you do not get a good bond using the white - sticky gormmet alone - you may have the water tube inside the ice maker freeze up.
Also once the new water line is installed be sure to secure the line to the metal back of the fridge - so the line will not move. some fridges come with metal hose clamps to do this - otherwise use duct tape
2. Removed black poly water line from valve (pull back on white ring where line is attached and pull the line out)
3. Removed the inlet tube from top-back of fridge (where it goes into the ice make). use putty knife to get under the sticky white gasket beneath the black oval housing and pull the tube out form the back of the fridge.
4. Replace the water line with new part taking care to properly seat the line into the the bottom water valve and pushing the water tube into the hole for the ice maker.
Note: Be sure to take off the protective covering from the white - sticky grommet and push to adhere to metal on fridge.
to be safe - use a bit of clear silicone chaulking round the perimeter of the grommet and push to tighly bond the water inlet tube to the fridge.
The reason for this - is that if you do not get a good bond using the white - sticky gormmet alone - you may have the water tube inside the ice maker freeze up.
Also once the new water line is installed be sure to secure the line to the metal back of the fridge - so the line will not move. some fridges come with metal hose clamps to do this - otherwise use duct tape
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Phillip from Springfield, VA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- M Alan from Lebanon, TN
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker door didn't open and close properly
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Sylva, NC
- Parts Used:
- WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Ice cubes froze in the tray and frost was all underneath
I read stories from the website how others did it so I figured I would give it a try. I put all the frozen stuff in the refrigerator piled up. Took out the shelves. Took out 2 screws with a socket extension ( nut driver will work fine.) Remove the light bulb. lifted up on the back panel...it came right out. Saw the coils and on top the sensor. Took it off, cut the wires, spliced in the color coded new one ( pink to pink, orange to orange) Stuck it in the top coil in the original position and crossed my fingers! I put all the pieces back easily, restocked the freezer and waited. HOORAY!! My ice cubes are all separate and free. NO frost inside. A very easy fix for $20.
Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
Was this instruction helpful to you?
Thank you for voting!