ZICP360SLCSS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Don from Crete, IL
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
cracked valve
Super simple. Extremely fast delivery of part. Simply disconnect the 2 fast-on connectors to valve, disconnect intake and out lines. connect intake and out tubes to new unit, mount via screws to fridge, reconnect the 2 fast-on power connectors and your back in business. Could not be an easier repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marie from Philidelphia, PA
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
replace filter
just had to unscrew old one put the new one in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Royce from Pasadena, TX
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Nothing to tell it was a replacement
Nothing to tell it was just a replacement part that the old part was removed and the new one inserted. Works like a dream Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from PLYMOUTH, MA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Ice maker needed replacement
Unplug refridge then loosened two bolts holding old ice maker. Lower then unplug and removed. Plugged in new harness and tightened two bolts to secure new ice maker. Plug in frig and wait for ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marie from Elk Grove Village, IL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
My ice breaker started leaking and making noise anf the stripper broke.
I ended up needing to order a new ice maker because the one I had is discontinued. I'm a 65yr old grandma and I did it myself!!!! The hardest part was finding the tool to loosed the nuts. I took the old one out and just put the new one right in it's place. Easy as pie.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from SAN ANTONIO, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker filled too full and ice froze in the basket and a piece was broke on the icemaker itself.f
My son did it , and showed me what he did when he was finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynn from MOUNTAIN HOME, ID
- Parts Used:
- WR30X10093
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- KEITH from WINDER, GA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
broken outlet valve
All the repair people was on the money . I read them all .1--- NO paper work with new valve (.no instructions) ..2--- bracket is not the same .. I reversed my braket and it worked fine .you do not have to bend bracket.3--- It will take a day or so to start making ice..4--- the plastic nut is no longer needed on the new type outlet valve ....5--- the new outlet valve looks a little different from the old valve. WORKS GREAT ..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from RINGGOLD, GA
- Parts Used:
- WR49X10283
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
compressor won't kick on
Pulled ice box away from wall. Took lower cardboard cover off. Shut water line off. Got my volt meter and checked the current going from the wall to the plug in at the inverter (input side), and I had the required 115 volts. Then I unplugged the connection going to the compressor (not the plug at the compressor which you cannot see until you unbolt the inverter) but the output connection side that goes to compressor. I checked the voltage and had about 13 volts not the required 115 volts. Therefore, I came to the conclusion that the inverter was bad. I ordered one from Partselect and they shipped it right away. I installed it and the ice box is back up to running order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Callaway, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Ice maker arm disconnected from frame causing problems.
The icemaker arm disconnected from the metal frame. This caused the icemaker to cycle and the heater to come on and stay on until the plastic parts melted causing a mess and stink. This action melted the ice and then the water fell through the frozen items in the freezer and refreezed in the lower portion. OK, I remover the dead icemaker and tossed it away. I installed the new icemaker and the wiring harness didn't fit right (way to long). I retrieved the old icemaker and removed the wiring harness from it. I removerd the new ice maker and installed the old wiring harness to the new icemaker. I then installed the new icemaker, plugged it in and turned on the power. No water, I ordered the dual solenoid water valve, installed it with difficulty (another story) the turned on the power. I reinstalled the ice bin and found it didn't fit. The icemaker was to low and couldn't be adjusted, 1/4" higher would have been great. I shoved in the bin anyway, I was out of ice for my scotch, and it started making ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Amanda from New Albany, MS
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker didn't work.
Replaced icemaker assembly. Only 3 Phillips screws to remove the old assembly. Pretty much an exact swap. Was easy to replace but the connecting cable on the new replacement assembly wasn't very easy to make fit. Had to force it into a location that would be out of the way and allow everything to operate properly. That connecting cable should be more flexible and adapt to the fridge a little more friendly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ted from Harrisonburg, VA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
icemaker stripper fall a part
instalation was very easy - but the part was 3/4 inch to long and a 1/32 inch to wide.Trimmed it with the "faithfull"
Dremel and it works!The instalation part of the "job" was less then 10 min.
Dremel and it works!The instalation part of the "job" was less then 10 min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Margaret from Virginia Beach, VA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
Ice maker would only make very small and very few ice cubes.
After determining that the ice maker on this relatively new refrigerator would make ice cubes if it received the proper amount of water. Ordered the valve and received in a couple days. Using a nut driver, removed the cardboard cover from the back of the refrigerator. Removed one screw holding the valve bracket to the fridge and removed another screw holding the water supply line and the water line to the ice maker in place. Pulled plug on fridge and removed 2 wires from valve. Removed inlet and outlet lines from old valve and reversed the process installing the new valve.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Russell from GLEN, NH
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set, Wrench set
noisy evaporator fan motor
Replaced evaporator fan motor, and this solved the whistling noise that had developed. Reviewed and followed the removal and installation instruction video as closely as possible. This was very helpful, with a few additions. For the model PS123NGPBBB GE refrigerator/freezer, there were a few differences from the video. There a was an additional cover panel that was positioned vertically at the back of the freezer compartment below the auger motor assembly. It was necessary to remove this cover (4 screws) to gain access to the auger motor cover screws. The unit also has a different light configuration with 2 lights. I found it helpful to remove these light bulbs and the corresponding light fixtures in order to remove the evaporator motor assembly. As mentioned in the video, it was necessary to cut the 4 wires from the wire harness of the new motor, and use butt end connectors to reattach these wires to the corresponding wires in the unit. Total job took between 1 and 2 hours, and the motor change solved the noise problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cliff from ROCKVILLE, VA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench set
The old solenoid was slow to shut off causing the icemaker to overfill.
Unplug refrigerator and turn water supply off to the ice maker. Remove the screws holding the bottom cardboard-like cover from the lower back of the refrigerator. Remove the water supply line to the old solenoid with 1/2 inch wrench. Unplug the two power supply wires to the old solenoid. Remove the screw that holds the solenoid to the back panel of the unit. After the solenoid is pulled out, remove the output hose with a 1/2 inch wrench. The configuration of the replacement solenoid is likely a little different than the original, but it seems to be rather universal and will fit back into place and perform properly. The new solenoid does not use a compression type nut to secure the output line. It's just a simple push-in connection. The wires may have to be rerouted a little, just keep them clear of the evaporator fan blades Reverse the removal procedure and you're done.
Was this instruction helpful to you?
Thank you for voting!