TBT18TABJRWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Anthony from COVINGTON, LA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The unit cycles but does not achieve proper temperature
Remove power from the unit. With short length #2 Phillips loosen and remove the two(2) screws on the control panel located center top of the refrigeration area. Slide the control panel back about 1/2 inch and allow it to dangle from its wiring harness. Pinch the locking tab on the harness connector with one hand and use the other hand to separate the two sides. A little force is required. Remove the control panel from the refrigerator and shut the refrigerator door. Examine and note the routing of the temperature probe (Silver colored flexible wire) take a picture for later reference. Remove the old and replace with new unit. route temperature probe like the replaced unit. Reverse the steps and reinstall the control panel. It is a good idea to also purchase and replace the defrost timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from DOUGLASVILLE, GA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Fridge never cuts off.freeze everything inside of fridge.
To remove the temp sensor.2 Phillip head screws not remove the cover inside fridge .the temp control knob cover.removed that and unplugged switch.installed new switch.reinstalled cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Boyd from Blaine, WA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Could not adjust temperature
Replaced temp controller
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- denis from freedom, NH
- Parts Used:
- WR60X203
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
was not defrosting
first i removed all the screws inside the freezer compartment took out theback and bottom to get to the evap motor,unpluged the wires and removed the evap motor ,removed the fan from old unit and put it on the new unit them mounted it to the back wall of the fridge,,, and put back top and bottom
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mackenzie from Williston, ND
- Parts Used:
- WR09X20002
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Compressor would randomly not turn on. Fridge too warm sometimes.
Replace temperature control. That fixed it. Also, removed plastic bag obstructing air vent in freezer which added performance. Fridge works good now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- glenn from la harpe, KS
- Parts Used:
- WR60X203
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
drain freezing up found cond fan not working
Cleaned oh t freezer removed floor. Removed back inside wall removed and replaced fan and put back removed parts
L
L
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- victoria from forest park, IL
- Parts Used:
- WR71X10077
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The part that holds the items in the door was bent.
I removed the brackets with the metal strip attached, from the door. I took a screwdriver and pressed down on the parts holding the strip to the brackets . I attached the new strip to the brackets and then attached the whole thing to the door.
Really easy to do.
Really easy to do.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jose A from WEST PALM BCH, FL
- Parts Used:
- WR09X20002
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Was getting too cold
Was only two screws after that carefully took the part away unplugging the wires at the same time was plugging in to the new part and was done after 5 or 7 min
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jamie from san clemente, CA
- Parts Used:
- WR71X10077
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
door shelf bar was bent and no longer holding in items
we ordered new bar, cut to fit with instructions, and voila! easy!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Catherine from SEATTLE, WA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paula from KEY BISCAYNE, FL
- Parts Used:
- WR51X444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Wrench set
Defrost Heater too old
I disconnected the old defrost heater removing 2 small screws and the electrical connectors, afterward I attached the new part, reconnecting back the electrical connectors and screwing the removed 2 screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from LEAGUE CITY, TX
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Change bulb
Easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rochelle from Culver City, CA
- Parts Used:
- WR71X10077
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
A cracked bar in the refrigerator door
I snapped out the old cracked bar and snapped in the new one!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roscoe G from ROCHESTER, NY
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Was this instruction helpful to you?
Thank you for voting!