- Customer:
- Richard from Chandler, AZ
- Parts Used:
- WR55X10942C
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer Temp Warm
Freezer would not defrost and ice would accumulate on the coils. After the GE repairman quoted me a price to defrost and repair it – which was ridiculous – I decided to tackle the problem myself. I am posting this comment as I found other comments very helpful with trouble shooting my problem. After reviewing other home owner repair comments I decided to first replace the upper sensor, thermostat and heater bracket assy. The longest task to do this was defrosting the coils. What a mess that turned out to be. The items were fairly easy to replace. The sensor and thermostat needed to be spliced and I used good techniques and sealed the splices with electrical tape. Defrost thru repair was about 3.5 hours. Unfortunately, this did not solve the problem and the temperature started rising after the coils froze over again. I decided to go one step further and replace the main board. One repair comment said that it is important to completely remove all of the frost before engaging the new main board – which made sense to me. The defrosting was easier and faster the second time as I plugged the drain below the coils, used hot water and then my shop wet vacuum to remove all the defrost water. Then I reversed the air flow to completely dry the coils. The main board installation instructions were fairly easy to follow. I took a picture with my camera just to ensure all the wires were installed properly. However, that was not necessary the plugs are unique and will only fit one way. The only problem was plugging in the power connector as it was in a different location on the board. With a little careful nudging it was successfully installed. Overall, a good experience and I am thankful for these repair comments by other!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Debra from Keystone Heights, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker wouldn't work and the fan was making a clicking noise.
First, I must say that I was told that the mother board might be the problem. I called my husband to tell him what I was told the problem might have been and how much the part was. A little expensive, but still cheaper than calling a repair man. He told me to order the less expensive part first to see if that fixed it. The fan motor. We hung up the phone and for kicks I scrolled down the page to see if it might give any more information on the part and what it controlled, etc. I don't usually read comments, but was amazed at the ones I read. The second comment on the page said that his refrigerator made a whooing sound like a ghost. Our Frig has done this since the day we bought it! He replaced the mother board and the "ghost" moved out! The third comment was that his refirg made a clicking noise and the ice maker doesn't work! I immediately called my husband back and told him I was ordering the part! It arrived the next day. So extremely easy to put in! I removed 3 screws from the cover, disconnected a couple of wires, a few plastic clips; pushed the new part on the clips rehooked the wires and put the cover back on. I bet it took less than 10 minutes! My husband thinks I'm a genius!! Thank you so much for all of your help!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- james from san diego, CA
- Parts Used:
- WR50X10068, WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Little or no cooling in refrigerator, compressor on 24hrs.
First, removed shelves and items in freezer.
Then, removed back panel using socket set and philips screwdriver which exposed iced over coils, then defrosted coils using hair dryer set on hot-high. This was the most time consuming part of repair-30 minutes. removed heater and bra's 2 screws and pulled electrical leads from both ends. Reconnected the two leads to new heater and bra, then reattached using 2 screws back onto coil frame. Cut thermostats 2 lead wires-one pink the other orange, reconnected leads from new thermostat with wire nuts, applied silicone to protect connections, then reattached onto coil frame. reattached back panel using socket set and philips screwdriver to re-attach bolts and philips screws, then cleaned any remaining water from the defrosting with dry towel. Attached freezer shelves, items and plugged in refrigerator freezer. Appliance works like it's brand new again.
Then, removed back panel using socket set and philips screwdriver which exposed iced over coils, then defrosted coils using hair dryer set on hot-high. This was the most time consuming part of repair-30 minutes. removed heater and bra's 2 screws and pulled electrical leads from both ends. Reconnected the two leads to new heater and bra, then reattached using 2 screws back onto coil frame. Cut thermostats 2 lead wires-one pink the other orange, reconnected leads from new thermostat with wire nuts, applied silicone to protect connections, then reattached onto coil frame. reattached back panel using socket set and philips screwdriver to re-attach bolts and philips screws, then cleaned any remaining water from the defrosting with dry towel. Attached freezer shelves, items and plugged in refrigerator freezer. Appliance works like it's brand new again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Greenville, NC
- Parts Used:
- WR62X23154
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Bluefield, WV
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Ice maker quit making ice
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Battle Creek, MI
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Unit would not run.
I found if I would put pressure on one connector on the board the unit would come on. So the board had a short. I ordered it, it came in 24 hours and I installed it and problem was solved.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- FERNANDO from MIAMI, FL
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Refrigerator Not Cooling due to ice buildup on coils
Removed shelves from freezer section and removed protective cover using a screwdriver and nutdriver. 5 screws.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from Edgartown, MA
- Parts Used:
- WR17X22070
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Water if refigerator door is really slow. Ice making is really slow.
Used by pass filter and problem disappeared. Of course wayer is now unfiltered. This is a GE design flaw. Also replacement filters are outrageously expensive and do not last long. We have good water here and I'll stick with the bypass.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Brentwood, TN
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.
Other than the two-screw problem, it was easy.
Other than the two-screw problem, it was easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Milton, FL
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Cave Creek, AZ
- Parts Used:
- WR30X10093
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Highlands Ranch, CO
- Parts Used:
- WR55X10942C
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Icemaker would not dispense cubes or crushed ice
Cause: Failed relays on main circuit board. Fix: Main circuit board replacement: Unplugged refrigerator. Removed 10 screws securing main circuit board metal cover (located on back of refrigerator) using a nutdriver. Disconnected 7 multi-pin electrical connectors from the circuit-board by firmly pulling each connector from the circuitboard sockets using a needlenose plyers. Depressed the small locking prong on each of the 4 plastic circuit board mounting pegs while pulling the board off the mounting pegs.
Pressed new board in place over mounting pegs. Re-plugged in all connectors (no confusion because each connector has unique pin counts). Replaced all mounting cover bolts, making sure to pin green ground wire to last bolt. Plugged in refrigerator. Done.
Note: I determined the main circuit board was bad by removing the auger motor assembly from the freezer and testing the auger motor harness power pins. AC voltage should jump when ice demand lever is pushed (while pressing the internal door light off switch). If no voltage jump, then auger motor relays on main circuit board have failed, indicating board replacement is needed.
Another check would be connecting an extension cord to the auger motor terminals and plugging it in. Motor should run. If it does, then motor is good and main circuit board is bad. If it doesn’t then auger motor is bad and needs replacement.
Pressed new board in place over mounting pegs. Re-plugged in all connectors (no confusion because each connector has unique pin counts). Replaced all mounting cover bolts, making sure to pin green ground wire to last bolt. Plugged in refrigerator. Done.
Note: I determined the main circuit board was bad by removing the auger motor assembly from the freezer and testing the auger motor harness power pins. AC voltage should jump when ice demand lever is pushed (while pressing the internal door light off switch). If no voltage jump, then auger motor relays on main circuit board have failed, indicating board replacement is needed.
Another check would be connecting an extension cord to the auger motor terminals and plugging it in. Motor should run. If it does, then motor is good and main circuit board is bad. If it doesn’t then auger motor is bad and needs replacement.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Victor from Houston, TX
- Parts Used:
- WR62X10055, WR17X11653, WR17X10706, WR02X10585
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The compartment behind control panel with snow
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.
I recomend these parts be replaced once time for each two years.
I recomend these parts be replaced once time for each two years.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joe from raleigh, NC
- Parts Used:
- WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
ice despenser door would stick open and frost up to the point of of ice not coming out
after finding the video describing the same problem, i gave it a shot. Major problem was figuring out how to take outside trim off of the ice/water dispenser. Everything i tried did not work like the videos i had seen. Looking thru some of the posted blogs i found another way to get behind the control panel without even taking off the trim piece. i pressed a 1/8th allen wrench into the two outer holes on the bottom of the control panel which released the panel to pull out from the bottom. after that it was simple to release the three plugs from the circuit board and remove the control panel. 4 phi lips screws later the ice chute comes straight out revealing the flapper door which is held in by 2 more screws. once that assembly is out the solenoid is held by three more screws. there was nothing difficult at all about this repair once the secret was out about the first step about the three holes (use only the outer two) in the bottom of the control panel
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from waxahachie, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
No water or ice and a constant ticking sound from the control panel
Very easy repair to do. Read instruction sheet before starting! Unplug unit prior to removing panel cover.
Remove three hex head screws holding control panel cover in place and reveal the circuit board.
Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.
Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.
Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.
Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.
Voila!! No more ticking sounds and a plentiful supply of ice and water!!
Remove three hex head screws holding control panel cover in place and reveal the circuit board.
Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.
Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.
Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.
Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.
Voila!! No more ticking sounds and a plentiful supply of ice and water!!
Was this instruction helpful to you?
Thank you for voting!