- Customer:
- john from waxahachie, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
No water or ice and a constant ticking sound from the control panel
Very easy repair to do. Read instruction sheet before starting! Unplug unit prior to removing panel cover.
Remove three hex head screws holding control panel cover in place and reveal the circuit board.
Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.
Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.
Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.
Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.
Voila!! No more ticking sounds and a plentiful supply of ice and water!!
Remove three hex head screws holding control panel cover in place and reveal the circuit board.
Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.
Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.
Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.
Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.
Voila!! No more ticking sounds and a plentiful supply of ice and water!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Lodi, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Suffolk, VA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ray from Salem, AR
- Parts Used:
- WR57X10086
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Water continued to flow after icemaker was full
Using nutdriver removed access panel on back. Unscrewed water supply line. Using nutdriver removed water inlet valve. The feed line to the icemaker is a pushlock connection so removed feed line. Then reverse process.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from PARRISH, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Windham, NH
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers, Socket set
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leonard from Keller, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Main circuit board wouldn't allow the compressor to come on
Removed old circuit board and replaced with new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jania from Novato, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Glendale, AZ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tracy from Yuba City, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cristina from Los Angeles, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Simi Valley, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- debbie from chino hills, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Milford, UT
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
fridge wouldn't cool, frozen food thawed
First my wife and i took the panel off the back, unscrewed the old mainboard, unplugged all the switches from it and prayed that the new one would work. We were without a fridge for 2 weeks beginning 2 days before Christmas!!!!! Gingerly, we put the new board in place, screwed it into the fridge, connected the switches, attached the ground wire, and held our breath as we plugged it back in. Within seconds, the familiar sound of water filling the icemaker was hear and there were cheers all around!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Spring, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
"Moaning Myrtle" syndrome. Refrigerator makes a whooing sound for hours at a time
Checked the internet for reports of similar problems and concluded that it was probably the main control board. Not being particularly handy, I would never have attempted to change the board myself if I had not read the comments and instructions from people on this site. Thanks.
The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.
The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.
I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.
The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.
I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
Was this instruction helpful to you?
Thank you for voting!