Customer:
David from White Pine, TN
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Would not cool top or bottom
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.

Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from Coram, NY
Parts Used:
WR72X10148
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Clips on slide assembly had sheared of from excessive force in loading the storage bin
Removed shelf assmbly from the refrigerator, slid the draw out and removed the left side slide assembly. The most difficult part of the repair was removing the the air flow lever from the slide assembly. Once thelever was out it slid easily into the slide assembly and then the slide assembly simply snapped into place on the shelf bracket. Took approximately5 minutes to repair.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Bayside, NY
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Icemaker solenoid housing cracked
The original piece was already removed. installation required a little custom fitting as the mounting was slightly different and the copper tubing from the water line needed to be bent to fit. The push in plastic connection (output to the icemaker itself ) was simple ( I was a little leary of it not leaking.)
I plugged in the solenoid connection first
I attached both water lines and checked for fit. Made the adjustments and then screwed the bracket back on to the refrigerator. I could only install one screw but it holds it fine. I did have to trim the hard press board(cardboard) a little to fit the new valve. I believe the board is to protect against dust build up on the mechanical equipment (motor, condenser,etc)
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Ft. Lauderdale, FL
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Wasn't Getting Any Water To The Icemaker
It could not have been easier. The new part matched the old part exactly. I turned the water off going to the refrigerator, unscrewed one screw from the old part, pulled the electric plug loose, disconnect the copper water line from old part, cut off the black plastic tube next to the water valve going to the icemaker, and the new water valve was ready to install. It's that simple. I then took the new water valve, connected the copper water line to it, pushed the black plastic water line into its hole, connected the electric plug, and screwed the new part onto the refrigerater. In a matter of minutes I had water running to my icemaker again. I can't imagine the money I saved by doing this simple project myself. This took less than 10 minutes.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dean from Folsom, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
8 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
O. V. from Virginia Beach, VA
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set, Wrench set
Ice maker water valve failed open.
The replacement single outlet water valve was not an exact replacement and required a slightly different mounting position. The original plastic hose to the ice maker attached to the valve with a plastic nut. The new connection requires only pushing the hose into a hole in the valve. Easy and simple. However, the new mounting angle promptly broke the brittle old plastic hose. I was able to pick the broken pieces of hose out of the valve with a fine point pick saving the new valve. If I hadn't been able to pick the broken pieces out of the new valve I would have had to order another one. Off to the big box store to buy new 1/4 inch plastic hose and a coupler. Repair completed and no leaks. If the hose hadn't broken, the I would have been done in 15 minutes. I suggest you plan to replace the entire plastic hose when you replace the valve.
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from Mountain View, AR
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Ice cream melting, lettuce freezing
Removed the back cover over the control board, and made sure that the board was the same. It didn't look exactly the same, but figured that it was the same, just updated. Took out the board, moved the wires to the new board and reinstalled. Plugged it in and it came on, so I reinstalled the cover. Seems to be working to this day.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Tiverton, RI
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer/Fridge not cold & compresser would not turn on.
For troubleshooting, I took off rear panel inside of the freezer compartment & determined that icing of the coils was not the problem & it did not apprear to be a defroster malfunction. All components appeared to be working properly except the compressor would not turn on and only room temperature air was being circulated by the fan. After narrowing the probable causes down to a faulty Main control board by reading as many similar posts as possible,I ordered the new control board. When it arrived the following morning via UPS(less than 24 hours!), I unplugged the wiring connections attached to the old board, (which was somewhat different in appearance), and then gently popped the circuit board off of the plastic retainer studs by pushing in the little retaining clip part of the studs in with a small screwdriver so the board could be released easier as I pulled outward. I popped the new board on the studs by gently & evenly pushing with a larger hut driver over the studs until it was locked in, being careful not to damage or over stress/bend the board. I placed the wiring connecters onto the pins on the board.....every connecter had a different amount of pins so improper connection was not possible. I placed the ground wire connection of the new board between the metal cover plate @ an adjacent screw location to ensure grounding to the back of the fridge sheet metal. I plugged in the refrigerator and was quite relieved when I heard the compressor start up after a second or two! Within moments the temp began to fall until it reached the proper temp in both compartments. Success!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alice from Vancouver, WA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers, Socket set
Ice maker stopped working.
I first replaced the ice maker and when that didn't work, I found out through this forum that another possibility is the water outlet valve.

When I got the replacement, it took some time to install because the bracket wasn't the same as the original. There are enough places on the bracket to mount the unit, but it may require using some force to bend the bracket so that it will flush with the wall.

After installation, it took about 2 days to fill up the ice bin. It cycles out ice crescents every 2-3 hours.

Thanks partselect for having this forum and saving me some money by having others share their experiences.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from San Marcos, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from Crete, IL
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
cracked valve
Super simple. Extremely fast delivery of part. Simply disconnect the 2 fast-on connectors to valve, disconnect intake and out lines. connect intake and out tubes to new unit, mount via screws to fridge, reconnect the 2 fast-on power connectors and your back in business. Could not be an easier repair.
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Clarksville, GA
Parts Used:
WR55X10942, WR55X24064
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Electric surge from lightening strike close to house
Obvious that main electronic board was fried. Refrigerator and freezer both not working although fan was running. Replaced main board and run capacitor. Compressor not running. Pulled starter relay and checked compressor connections for continuity. Checked ok. Ordered starter relay and installed with new capacitor. Compressor started and has been running quiet and cold ever since. Thanks to videos on partsselect website for offering the confidence to try the fix myself. Total spent on parts and shipping,$350. I had electric provider install surge protection behind meter for a cost of $5.70 a month. Hope it works as advertised.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rickey from DUMAS, AR
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugged it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kirk E from GRASS VALLEY, CA
Parts Used:
WR55X24064
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.

Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from WINTERVILLE, GA
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!