TFJ28PFDBAA General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Enrique from east stroudsburg, PA
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Therefrigerator side was not cooling
I removed the cover on the back of the freezer side of refrigerator to expose the anti freeze element use the hair blow dryer to melt the ice on the coils put 2 towels to colect the water thats wath take me time, to replace the heath element was a 1 minute job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Hills, IA
- Parts Used:
- WR62X23154
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Crushed Ice Only
Let me start by saying, I usually hire something like this out but figured I would give it a try. The install was fairly straight forward, however it would’ve been nice if the instructions would have been more useful. Instructing me to remove one screw to release the auger and solenoid enclosure wouldve been nice. There were 3 other screws that I didn’t need to remove and they were the ones holding the auger in place, which made assembling that much more difficult. Once to enclosure was removed, and the solenoid was exposed, it was a seemless process. I would however, recommend paying attention to or taking a picture of the connections on the solenoid. I was lucky to remember or got lucky. Regardless, I was able to complete the project successfully. If I had to do it again, I believe it can be done in 30 minutes or less.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyoko from Bellevue, WA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
frost/ice buildup in icemaker chute in the freezer door
The only difficult part was not knowing which parts had to be removed to gain access to the flapper to replace it. It appeared as if the frame around the control panel would have to be removed as well as the door handle; we tried but were not able to remove the frame. It turned out that the panel just popped out with the frame in place. Once we had access to the flapper, it was easy to replace it. The repair fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Wyckoff, NJ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker stopped making ice
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wenshui from Irivne, CA
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ice build-up in back of freezer, not cool enough
Defrost heater turned black. Test showed infinite resistance. Problem went away after the heater was replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Colleyville, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Anaheim, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
The icemaker quit making ice and the water started forming on the bottom of the ice bucket.
First I removed the electrical plug from the back of the freezer that plugs into the icemaker. I then removed the two hex head screws that hold the icemaker to the wall of the freezer and removed the icemaker. I removed the plastic cover, which incidentally protects the gears, by prying it off with a srewdriver. I removed three small nuts(7mm) which holds the internal cam in place. I removed the cam by pulling it off the shaft. Once I got the part from you folks I reversed the procedure that I just mentioned, and put the icemaker back together. It works great. The part with shipping was around $16.00. A new icemaker was roughly $159.00. If I would have called a technician it would have cost around $300.00 to repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from HAZELHURST, WI
- Parts Used:
- 7C7
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light bulb in my freezer door burned out.
Remove the burned out bulb and install the new light bulb.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Philip M. from SIMPSONVILLE, SC
- Parts Used:
- WR32X1461
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
GE vegetable drawer broken.
Concerned about removing and attaching front panel to broken drawer. Rep. said wasn't sure but most just snapped together. Rep. was correct. No tools required.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from BRICK, NJ
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
My ice container and Ice chute were freezing up and getting blocked, and my filtered water line was also freezing
I just followed the instructions on the video and it was exactly as they said......no surprises.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jimmie from Surprise, AZ
- Parts Used:
- 7C7
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Bulb burned out.
Screwed new bulb in socket
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christine from Delray Beach, FL
- Parts Used:
- WR17X10542
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
drawer facing cracked
ordered drawer face - perfect part- snapped right in. done. order came within 10 days.
will order again if needed.
will order again if needed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Cary, NC
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frost buildup in freezer by the ice maker
Replaced dispenser door flapper by following the do it yourself video in this site. It was really easy. Just be careful when removing the dispenser black bezel. I broke one of the little tabs when taking it off.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cary from ORLANDO, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers
Ice maker stopped working
Remove the one screw holding the unit in place, unplug it, slide in the replacement, plug and screw it in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Champaign, IL
- Parts Used:
- WR51X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
howling sounds in the freezer; blower fan cycles on/off
------------- defrost heater replacement --------------------------
- unplug the refrigerator
- unload all shelves underneath ice maker
- move ice crem into the refrigerator section
- remove all shelves and the bottom tray.
- remove light bulb cover and the bulb
- unscrew two 1/8" screws on top corners of the back panel
- unclip the ground clip on top
- pull the back panel up; pull the left side toward yourself
- test 3 thermistors (see instructions below)
- test the thermostat (see instructions below)
- if either thermistors or the thermostat units are defective, they may be the reason for fan malfunction, not the fan itself.
- unscrew 2 philips screws on either side of the defrost heater
- pull it out and unplug the 2 wires on either end. Replace with a new part.
- putting together is the reverse of disassembly
- move ice cream back to the freezer
--- thermistor testing
- unplug the refrigerator
- locate thermistors to be tested. There's one on evaporating coils, one on bot. left of the freezer (behind deep tray, with white wires), 1 in fridge section (top left, in the corner, inside square white wire conduit; undo the top 1/8" screw ONLY and pull conduit up).
- without disconnecting from the circuit, place a thermistor in a cup of ice water. Wait for 5 minutes
- locate the main control board. Locate and unplug the J1 connector. The pinout, starting from the side with all wires connected:
* pin 5: ground
* pin 4: evaporator thermistor
* pin 3: freezer
* pins 2,1: fresh food thermistor
- use an ohmmeter to measure resistance. Push the needle of the ohmmeter into the socket, where the wire plugs in, without trying to remove the wire. It should be 16.3 kOhm +/- 5% (for 0 deg C)
to replace a thermistor
- cut out the old thermistor, leaving as much wire as possible
- strip the wires, twist them pairwise
- use a bell connector filled with RTV silicone, to ensure that no moisture can get to the connection
* others have also used butt splices and screw-on caps with electrical tape (for moisture isolation)
- using a proper crimping tool, squeeze the bell connector to secure the wire
------------- thermostat testing ---------------------------------
- it's a round quarter-sized cylinder w/ pink and orange wires
- check for bulging (= burnt)
- locate temperature ratings on the side of the thermostat. It should read e.g. 140-30F. This means it's switches to open circuit when >140F is reached and switches to closed circuit when <30F is reached.
- unplue the 6 pin connector that has thermostat.
- test the thermostat. Orange wire is in the 6-pin connector; pink wire can be disconnected from the defrost heater under the evaporation coil. It should read closed circuit (no R).
- place the thermostat into a cup of boiling water. It should open.
- if OK, reattach the thermostat
- unplug the refrigerator
- unload all shelves underneath ice maker
- move ice crem into the refrigerator section
- remove all shelves and the bottom tray.
- remove light bulb cover and the bulb
- unscrew two 1/8" screws on top corners of the back panel
- unclip the ground clip on top
- pull the back panel up; pull the left side toward yourself
- test 3 thermistors (see instructions below)
- test the thermostat (see instructions below)
- if either thermistors or the thermostat units are defective, they may be the reason for fan malfunction, not the fan itself.
- unscrew 2 philips screws on either side of the defrost heater
- pull it out and unplug the 2 wires on either end. Replace with a new part.
- putting together is the reverse of disassembly
- move ice cream back to the freezer
--- thermistor testing
- unplug the refrigerator
- locate thermistors to be tested. There's one on evaporating coils, one on bot. left of the freezer (behind deep tray, with white wires), 1 in fridge section (top left, in the corner, inside square white wire conduit; undo the top 1/8" screw ONLY and pull conduit up).
- without disconnecting from the circuit, place a thermistor in a cup of ice water. Wait for 5 minutes
- locate the main control board. Locate and unplug the J1 connector. The pinout, starting from the side with all wires connected:
* pin 5: ground
* pin 4: evaporator thermistor
* pin 3: freezer
* pins 2,1: fresh food thermistor
- use an ohmmeter to measure resistance. Push the needle of the ohmmeter into the socket, where the wire plugs in, without trying to remove the wire. It should be 16.3 kOhm +/- 5% (for 0 deg C)
to replace a thermistor
- cut out the old thermistor, leaving as much wire as possible
- strip the wires, twist them pairwise
- use a bell connector filled with RTV silicone, to ensure that no moisture can get to the connection
* others have also used butt splices and screw-on caps with electrical tape (for moisture isolation)
- using a proper crimping tool, squeeze the bell connector to secure the wire
------------- thermostat testing ---------------------------------
- it's a round quarter-sized cylinder w/ pink and orange wires
- check for bulging (= burnt)
- locate temperature ratings on the side of the thermostat. It should read e.g. 140-30F. This means it's switches to open circuit when >140F is reached and switches to closed circuit when <30F is reached.
- unplue the 6 pin connector that has thermostat.
- test the thermostat. Orange wire is in the 6-pin connector; pink wire can be disconnected from the defrost heater under the evaporation coil. It should read closed circuit (no R).
- place the thermostat into a cup of boiling water. It should open.
- if OK, reattach the thermostat
Was this instruction helpful to you?
Thank you for voting!