PTC22MFMARCC General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Roger from CAMARILLO, CA
- Parts Used:
- WR17X22070
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Leaking around filter bypass plug
Took old one out with my fingers. Put new one in with my fingers.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roscoe G from ROCHESTER, NY
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from HAZELHURST, WI
- Parts Used:
- 7C7
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light bulb in my freezer door burned out.
Remove the burned out bulb and install the new light bulb.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from HAYMARKET, VA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Flapper was worn and misshapen allowing warm air in freezer, ice cubes to melt and drip and impairing function of ice dispenser. Frost formed in ice dispensing chute also.
Followed the online video. Unplugged refrigerator, removed trim piece, lifted control board cover, removed 4 screws retaining circuit control board and removed the 3 connectors from the control board. Located flapper and removed by using small flat tip to take tension off flapper connectors. Helper held flash light to illuminate flapper connectors. Reversed procedure. New flapper seals well and cured problems. Circuit board was a bit different than one in video, but still had the 3 connectors. Marked each connector with grease pencil at top edge to ensure correct reconnection. Should note how wires are threaded around circuit board to ensure they are tucked back in correctly in reassembly. Remove trim piece carefully. I broke 2 of the 8 plastic pins that hold trim on. May be due to age of unit as they were brittle. 6 pins still hold trim piece flush.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from BRICK, NJ
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
My ice container and Ice chute were freezing up and getting blocked, and my filtered water line was also freezing
I just followed the instructions on the video and it was exactly as they said......no surprises.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gratnie from Newport News, VA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Water dispenser would not stop leaking on the unit.
First, turn off main water valve. Then, at the rear of refrigerator remove the rear panel exposing the water valve assembly. Cautiously, proceed by disconnecting the water hose and electrical connections. To complete the task, just worked in the reverse steps to exchange the faulty equipment.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from DYERSBURG, TN
- Parts Used:
- WR17X22070
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Slow water flow from water dispenser.
Took out the MFW filter.
Screwed in the MFW bypass.
Dispensed several gallons of water.
Saw good flow of water.
Removed MFW bypass.
Replaced MFW filter.
Our water flow was back to normal.
Screwed in the MFW bypass.
Dispensed several gallons of water.
Saw good flow of water.
Removed MFW bypass.
Replaced MFW filter.
Our water flow was back to normal.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from LEAGUE CITY, TX
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Change bulb
Easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William c.. from Barberton, OH
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
water leak
got new filter
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Kingsport, TN
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Scheduled replacement
Turned the old filter loose, removed the adapter from it, put the adapter on the new filter and turned the new filter back into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Al from River Edge, NJ
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker discharge was slow and jammed with ice and frost. The cause was a distorted flapper that did not seal properly, admitting warm air into the dispenser chamber.
Excellent video was available on the Parts Select website. It was simple. The selector panel pulled out by hand from the bottom. The subpanel was removed with the four screws. The flapper snapped out of the holder with two clips. The new one was inserted in reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paul from Suwanee, GA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
Water valve leaked
Diagnosis: I removed the nuts holding on the panel at the back of the refrigerator and saw water leaking from the water valve.
Repair: I guided my 10 year old daughter through the actual replacement.
Using a nut driver, unscrew the single nut holding the value to the frame of the refigerator.
Push up the rings around each water tube to release the tubes from the value. Using a wrench, unscrew the supply line.
Put dab of plumbers teflon on the threads.
Reverse all the above:
Screw in supply line, tighten with wrench.
Push water lines for icemaker and chilled water into value assembly.
Position valve and screw in het nut that attaches it to the frame.
Replace rear cover plate and screw in the hex nuts.
Repair: I guided my 10 year old daughter through the actual replacement.
Using a nut driver, unscrew the single nut holding the value to the frame of the refigerator.
Push up the rings around each water tube to release the tubes from the value. Using a wrench, unscrew the supply line.
Put dab of plumbers teflon on the threads.
Reverse all the above:
Screw in supply line, tighten with wrench.
Push water lines for icemaker and chilled water into value assembly.
Position valve and screw in het nut that attaches it to the frame.
Replace rear cover plate and screw in the hex nuts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ken from Wesley Chapel, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
froze in freezer
unclipped and replace with new part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joselito from riverview, FL
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Building Up In The Ice Dispenser Chute
Under the control panel there are three small holes. Insert ballpen or small flat screw driver on both outer holes to push a tab lock that holds the control panel in place. Then pull out control panel and three set of wires will be exposed and disconnect wire connectors (connectors have different sizes so you wont get confused in reconnecting). Unscrew four screws on each corner that holds the ice dispenser assembly (a part where you push your glass against to dispense ice or water. The flapper is exposed and easy to replace.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GARY from LIVONIA, MI
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice Maker Clogging up from frost build-up
Turn off power
Remove operator faceplate by pullling out on outer lower corners
Disconnect wire connectors from circuit board
Remove four screws from dispenser and pull out dispenser assy
Replcae Door ASsembly
Put everything back in place
Power up
Job Done
Remove operator faceplate by pullling out on outer lower corners
Disconnect wire connectors from circuit board
Remove four screws from dispenser and pull out dispenser assy
Replcae Door ASsembly
Put everything back in place
Power up
Job Done
Was this instruction helpful to you?
Thank you for voting!