Customer:
Joe from Woodbury, NJ
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Refrigerator door would not close properly
I first removed all of the door contents. I then removed the door from its mountings by removing two screws at the bottom bracket. With the door lying on the floor I then removed the two screws holding the door cam assembly in place. I inserted the new door cam, then reversed the process replacing the four screws.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
HERBERT from Harlingen, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
gasket was shot
took off the panel, took out 4 screwws, took out old flap, installed new flap, put screws back in , and put trim back on.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
vincent from mahwah, NJ
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
door was not closing properly
Your vidio was Brilliant !!i just followed your instructions
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Upper Malboro, MD
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Door would not shut by itself.
I followed the directions on the computer and everything went just as the video said it would. This was one of the easiest repairs I have ever done. Usually, it does not go as planned.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Neal from Cleburne, TX
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Door would not close properly
Removed the door and loosened the bottom bracket and scraped the old cam off. Mounted new cam and tightned the bracket. Replaced door and it was a total sucess.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
VINCENT from SPOTSYLVANIA, VA
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Tab that holds light shield was broken off.
Removed ice tray and set on kitchen counter .One small phillips scredriver to remove broken tab.
Attached replacement shield with screw, replaced ice tray. Probaly total of 5 to 10 minutes to find scredriver, do the repair & replace screwdriver where it belonged. Took more time to place order then do repair. Add a couple of minutes to unpack.and some more time to drop off cardboard box at recycle center.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Burmingham, AL
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Problem closing door, would not shut easily.
My wife and I gave an old, but really good refergerator to our son (a Major in the Army). Upon taking it into his house he had to remove the doors of the refergerator. While he put the doors he lost the "cam" for the door, making if difficult to close (actually had to lift the door up and then close it). I ordered the replacement part, and unless I am mistaken, it arrived the same day. I still cannot figure out how this happened, but it was great!!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from University Place, WA
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken part due to age
Super fast replacement, and the part was sent to us FAST and WELL-PACKAGED and REASONABLY PRICED! Thankyouverymuch!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeff from Wooster, OH
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Door closing cam (made of Plastic) just wore out with age and broke in half
Took the door contents out and put them on the counter, took the door off the hinges by unscrewing the 2 screws on the top of the Fridge and lifting the door off the hinge onthe bottom. Then laid down the Fridge on the kitchen floor and replaced the Door Closing Cam, keeping in mind the order of the 3 shims and other things on the bottom of the door. Simple.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Darien, IL
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Door won't close
This my second time to do it after 8 years. Took 10 minutes.
1 Remove all the contents on the side door
2 Remove the 2 bolts on top connecting the door to the refrigarator
3 Lift and remove the door up and put it the side
4 Clean and remove the old door closing cam put the new one
5 Door ref is fixed
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Oxford, GA
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light Shield old and damaged from the heat from the light bulb.
I only installed a light shield. However, I injoyed using your web site. It was easy and much better than Repair Clinic web site. I'm a do it your self person and this is the site I will return to!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DAVID from NEWPORT, PA
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Door would hang up half way closed
Replaced both upper and lower cam's. Removed door from refrigerator, removed bolts on door cam on bottom of main door and replaced cam, then removed bolts from door hinge assembly, drilled out rivet holding on cam, replaced with new cam and re-riveted.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
tt from Springfield, MO
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Shield was broken making it easy to break the inside light
Because of the way it broke I was not sure how it was attached until I read reply's from others who had the same problem. The instillation tip was greatly appreciated.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ron from San Antonio, TX
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Door would not stay open
Removed the top cover using a Phillips screw driver to access the top 2 screws holding the bracket. Once the bracket was removed, lifted the door off the bottom hinge. Replaced the door closing cam, replaced shims and screws. Placed the door back on the bottom hinge, inserted the top bracket and secured.
This was the ultimate resolution to the problem. The problem I encountered was getting all of the correct parts. It took me 3 tries to finally identify and receive the parts needed to make the repairs. Using Part Select made it easy because they had the parts I needed. My 3 tries were partly my error and does not reflect on Part Select. I would recommend others use Part Select when choosing their replacement parts.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Chesterfield, MI
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Refrigerator door would not close by itself - would stay open when you thought it was closed
1st: Order (2) closing cams! One for the hinge pin / bracket and one for the bottom of the door.
The closing cam on the door was where the Dremel type tool is required, since you have to grind the head off of a factory rivet.
I installed the cam with an aluminum pop rivet.
Next, remove the bracket on the bottom of the door with sockets and install the second closing cam.
Re-attach the top door hinge pin and align visually; tighen all bolts. Job finished, but more important , my wife is not nagging me about the repair that I put off for over a year!!!!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TFK24PRXCAA
121 - 135 of 233