- Customer:
- calvin from annapolis, MD
- Parts Used:
- WR62X10055, WR17X11653, WR17X10706, WR02X10585
- Difficulty Level:
- Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jason` from Colchester, CT
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Republican City, NE
- Parts Used:
- WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker door failed to close letting ice melt
Removed the front panel on the door that has the ice maker controls. Removed the screws and parts. Reassembled the parts and it works better than new. Ice door closes firmly and holds tight.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Billings, MT
- Parts Used:
- WR17X11267, WR17X11170, WR17X10745
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Melted Dispenser Housing Shield with hair dryer trying to thaw out frozen water line
Pull plastic trim piece off refridgerator door,unclip printed circuit board and remove wires unscrew dispenser housing,and remove. Transfer Ice funnel to new dispenser housing with old spring. Reinstall dispenser housing and printed circuit board.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- lk from carlsbad, CA
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Loud knocking noise with the evaporator fan
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).
I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Simi Valley, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Jupiter, FL
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Boise, ID
- Parts Used:
- WR17X23191
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Auger broken, and clear plastic piece at exit of bucket broken.
Pulled old assembly out, emptied ice, installed new assembly, filled with the ice already made. Less than 1 minute.
Worked like new for a week. Now, auger won't turn. Have no idea what the problem is, but I'm assuming it's the motor that turns the ice bucket auger, because the auger turns by hand. The bucket ass'y. was in need of replacement, but now I'm wondering if it was worth the money because of this new problem.
Worked like new for a week. Now, auger won't turn. Have no idea what the problem is, but I'm assuming it's the motor that turns the ice bucket auger, because the auger turns by hand. The bucket ass'y. was in need of replacement, but now I'm wondering if it was worth the money because of this new problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jaci from Grand Island, NE
- Parts Used:
- WR17X23255
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Ice maker was not working
Shipping service was great> Ordered on a Friday, received it on Tuesday. Slipped out the old one and put the new one in and it works great
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Goshen, KY
- Parts Used:
- WR23X21444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken freezer light switch
Part arrived very fast as ordered..need to pry old switch out from top..use care to push the retainer down..after old switch was 1/2 out, I used a putty knife for better leveridge.Remove wire connector...after plugging in the wire connector to the replacement switch, make sure the switch is properly positioned so the switch will depress when door shuts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Virginia Beach, VA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Flapper was stuck open. Old and warped.
Replaced flapper
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura from Manchester, NH
- Parts Used:
- WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- roy from spring hill, KS
- Parts Used:
- WR02X10552
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
going from warm to to cold
i used the video it showed on the site or iwould not have been able to do it
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Glendale, AZ
- Parts Used:
- WR17X11267
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice funnel cracked
Followed video for replacing the ice chute flap solenoid replacement because getting to the ice funnel took same steps of disassemble. Looked at how the existing funnel was set in the housing, where and how one spring was located, where the switch and its activating arm on the ice funnel were located, took old one out and put new one in. Cleaned everything in process.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from west bend, WI
- Parts Used:
- WR17X11170, WR49X10233
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The unit will not dispense water, but does make and dispence ice.
I replaced that part, but I still have the same problem, no water is dispensed. I believe I may need a circuit board. The problem was not the parts I replaced.
Was this instruction helpful to you?
Thank you for voting!