PSE25NGTECWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Arthur from Richmond, VA
- Parts Used:
- WR02X45206
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench set
no water from door water dispenser and valve chattered
Removed water filter and turned off water supply. Remove the metal plate at the rear bottom of refrigerator and the metal plate at the top rear of the refrigerator that covers the exit of the filter housing from the refrigerator. Then disconnected the water supply line and water line from the filter housing mount to the valves that control water to the door and ice maker. From inside the refrigerator, removed the two bolts holding the filter housing and then removed the filter housing and tubing. Reversed the procedure to install the new top filter housing mount with tubing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Goshen, KY
- Parts Used:
- WR23X21444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken freezer light switch
Part arrived very fast as ordered..need to pry old switch out from top..use care to push the retainer down..after old switch was 1/2 out, I used a putty knife for better leveridge.Remove wire connector...after plugging in the wire connector to the replacement switch, make sure the switch is properly positioned so the switch will depress when door shuts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Virginia Beach, VA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Flapper was stuck open. Old and warped.
Replaced flapper
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bert from Audubon, PA
- Parts Used:
- WR60X30922, WR02X12149, WR02X11331, WR02X10322
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
High pitch noise
My GE refrigerator emitted high pitch noise a short while ago. I tried different dampening methods that helped but not eliminating the problem. I finally replaced the fan, motor, and associated parts and solved the problem. The total cost was about $50.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gary from downey, CA
- Parts Used:
- WR17X11497, WR17X11505, WR01X10315
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
plastic crusher cover broke
look very carefully at the picture you provided in the parts fish, removed the ice maker tray and the rest was very easy ,i saved alot of money and time doing it myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- dwight from phoenix, AZ
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
slow water flow in dispenser
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from Anderson, SC
- Parts Used:
- WR29X43990
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Ice Bucket Auger Broken
This repair was very simple to do. I cannot say enough about part select dot com. I feel that I am a definite handy man yet the videos on the part select dot com site proved to be valuable. This video showed and reminded me that the plastic bushing holding the auger on was reverse threaded. Being a rightee tightee leftee loossee person embedded in my head I would have worn out that bushing holding the auger in place. I recommend not only purchasing from partselect.com YET please watch the video on this site prior to this installation. This made the installation not only simple yet informative. Thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- roy from spring hill, KS
- Parts Used:
- WR02X10552
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
going from warm to to cold
i used the video it showed on the site or iwould not have been able to do it
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura from Manchester, NH
- Parts Used:
- WR02X11330
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bernard from Bay shore, NY
- Parts Used:
- WR24X10156, WR24X10155
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
Freezer door would open when food door would close
Bought two gaskets for both doors was just going to replace both due to age. Food door gasket was received damaged shipped poorly and I am still waiting on a refund. But went ahead with the repair , since freezer door was the one I was concerned about. Opened Freezer door gasket package and it was dirty and looked old from sitting in warehouse. I had to but it in the tub to make it pliable and I cleaned it also since it was in water already. Installed it pretty simple . Turned out the refrigerator wasn't leveled properly. Didn't realize the refrigerator is suppose to slope to the back . Called up GE and they helped me out. Customer Service from partselect.com and GE were very nice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Andrew from Loganville, GA
- Parts Used:
- WR17X11497
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Cover was cracked affecting ice dispensation
Removed the ice tray and then the auger unit from the tray assembly. To accomplish auger removal, the auger assembly is attached to the tray assemble at the front. On the front bottom there two screws. Back them out. Then on the top of the tray assembly the auger assembly is held in position by two tabs. Depress them with a finger or thumb. Do not use a screw driver as this may result in breaking the plastic tab! The auger assembly will separate. The crusher plate easily separates from the auger assembly and is removed buy "spiraling" the plate up and off the auger itself. Simply reverse to install new plate.
Recommendation: Take this opportunity to thoroughly clean and COMPLETELY DRY all components prior to re-assemble and re-install into the refrigerator.
Recommendation: Take this opportunity to thoroughly clean and COMPLETELY DRY all components prior to re-assemble and re-install into the refrigerator.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- mike from Aguilar, CO
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Merlin from Dawsonville, GA
- Parts Used:
- WR29X43990
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Broken Augar
I am 85 years old and had no trouble replacing the Augar. Removed ice maker from frig. Remover the ice shield (one screw, remove front panel (2 screws) carefully removed augar assy.
Removed the lock washer,the the end plastic nut, being careful in removing the ice crusher blades. Replaced the augar and all parts. Checked out the ice dispenser and the crusher, both worked fine
Removed the lock washer,the the end plastic nut, being careful in removing the ice crusher blades. Replaced the augar and all parts. Checked out the ice dispenser and the crusher, both worked fine
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patsy from Jal, NM
- Parts Used:
- WR29X43990
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
replace auger in the ice maker
We had a little difficulty getting the washer back on properly because my husband could not remember how he took them off. I finally got the parts in front of my computer and brought up the picture of the auger and parts that showed me how to put the washer back properly and we got it back together and it works fine. Not bad for two old people I am 80 and my husband is 79 but we still take pretty good care of things.it would have been a little easier if I could have printed the picture off, but we made it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael D. from Boiling Springs, PA
- Parts Used:
- WR29X43990
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Augur blade broken
Ice maker assembly removed from refrigerator and disassembled. Note nylon nut holding the Augur in place is removed clockwise. As you take the assembly apart, note each piece for reassembly.
Was this instruction helpful to you?
Thank you for voting!