Models > CWE19SP4NXW2 > Instructions

CWE19SP4NXW2 General Electric Refrigerator - Instructions

Jump to:

All Instructions for the CWE19SP4NXW2
61 - 74 of 74
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Vernon from Harmony, NC
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
coil frosting up and refridgerator section was not cooling
took out shelves and removed the back plate my removing 2 screws with a nutdriver.removed the old defrost timer and defrost heater which was really easy.then installed the new ones.the video i watched on the website was really helpfull.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Zachary from Decatur, GA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Fridge was freezing food near the back, adjusting internal temp not fixing the problem
Unplugged the refrigerator first....then on the inside of the fridge, I popped the temp sensor cover off (upper LH side) and exposed the old sensor. I snipped off the old sensor about 3" down from the end and connected the new sensor (which I trimmed down to about 3" long) with some heat shrink wire nuts/connectors. Let the fridge run for a day or so and confirmed the problem was solved! Oh yeah, there was no way to tell the 2 wires apart (power vs. ground) on the sensor. However there was a manufacturer's stamp on the wires. So note the orientation of the text and mark one of the wires with a sharpie on both the old and new sensor before trimming. This will give you a reference for which wires to connect when adding the new sensor to the old wires.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Island Lake, IL
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
frige too cold
changed sensors did not repair problem,replaced damper with mechanical damper fixed problem.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brandon from Bruceton Mills, WV
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Defroster stopped working and iced up evaporator coil
I have a GE Profile French door refrig. It's only about 4 yrs old and the defroster stopped working. I read the other repair stories and was able to narrow it down to either the temp sensor, defrost timer, or main board. The refrig section was up to about 47 degrees and freezer was around 25. I could tell it was trying to cool but couldn't. So I tried the temp sensor first. I cut and spliced the new sensor on the outlet of the Evap. Coil and it took about 15 mins. Turned refrig back on and waited. The coil started to ice over after about 5 hrs I left the back panel off so I could see if and when then heater kicked on. After about 8 hrs I looked in and saw a faint glow and water trickling down and running out the drain. Turned out the sensor was bad and wasn't telling the main board it needed to defrost. I would try the sensor if you are having the same issues before spending a lot of money on the main board, defrost heater and or timer.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from silver bay, MN
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Fridge Side Freezing/Too Cold
Followed the repair video, was spot on!!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason Mcgee from Catawissa, MO
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer would not defrost or maintain temperature
luckly i have a bit of experience in refrigeration im an hvac technician by trade. this repair was a bit tricky in that i did not know at first if it was a Temperature Sensor issue or the main control board. I had tested the defrost termination thermostat and the defrost heater and as i suspected they were ok. Next i wanted to test the thermistors (temp sensors) it is hard to find technical data on these fridges. I needed to test the thermistors resistance @ a certian temperature to ensure they were working properly but where do u get such data? I also wanted to know some information about the logic programmed into the board (i.e when do you initiate defrost etc. . .). I had no such luck so i figured since i tested the defrost heater and thermostat and they were ok and all of the evap fans and such were working i'd order a circuit board and new thermistors. Got the CORRECT PARTS from this site in 2 business days and my fridge is working great! changing the parts was really easy, figuring out which parts to change was the only difficult thing about this job.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CWE19SP4NXW2
61 - 74 of 74