GSE23GGPFCBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Stephen from Los Angeles, CA
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Door flapper would not self-close
I replaced the original solenoid, which had rusted into one solid piece. OMG how easy was that!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward N from Boyds, MD
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker Door flap would not close all the way
Went on this site, found out many others like me had the flap door stuck open problem, it would not shut after you went for ice. I needed a new solenoid that opens when the ice is dispenced and closes afterwards not allowing the warm ambient air to come up the shoot which frosts the ice and melts it. It shipped QUICK and now I have a working ice maker dispenser from the outside. Its been 2 YEARS of opening the door and reaching into the ice maker bin for ice! Thanks PartSelect
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter M. from Lincoln Park, NJ
- Parts Used:
- WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mitchell from Olive Branch, MS
- Parts Used:
- WR17X11440
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Water tank froze and busted
Cut old tubing in frig with wire cutters and pulled through the bottom wall and removed old tnak from the wall...Installed new tank and ran tubing down trough lower wall and connected to the valve and the freezer door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyoko from Bellevue, WA
- Parts Used:
- WR17X11653
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
frost/ice buildup in icemaker chute in the freezer door
The only difficult part was not knowing which parts had to be removed to gain access to the flapper to replace it. It appeared as if the frame around the control panel would have to be removed as well as the door handle; we tried but were not able to remove the frame. It turned out that the panel just popped out with the frame in place. Once we had access to the flapper, it was easy to replace it. The repair fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from st aug, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Coppell, TX
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bryan from Fairfax, VA
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer frosting up around ice dispenser chute.
Ordered new solenoid so the flap would close. That did the trick.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vernon from NEW PRT RCHY, FL
- Parts Used:
- WR32X32346
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
My bottom drawer in my GE refrigerator was broken.
Pulled out broken drawer and inserted new drawer...just that simple!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Colleyville, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cyndy from Rancho Cucamonga, CA
- Parts Used:
- WR23X31507
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
I dropped one of the trays and it hit the light switch and broke off!
It was so darn easy! Took less then 10 minutes to fix. Self explanatory no instructions needed! Very cool!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Shelton, CT
- Parts Used:
- WR82X10103
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
brand new ge refrigerator delivered with broken access cover. cost 6.95 so i repaced it myself.
removed 6 screws and repaced cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Benjamin from Goldsboro, NC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice flap in door wouldn't close
Take the face (the part with the buttons on the outside) off, disconnect wired connectors (three), take the screws out of the part behind that (4), and then find the solenoid value (on the right). It's attached with three screws. Mine was rusted beyond belief. I knew this was the problem, ordered a new solenoid valve, put it back in place with three screws (use new screws that fit, not the old rusty ones if possible). When testing, make sure you give the flap a couple of seconds to close. There is a delay, and I initially wasn't patient enough so I had to disassemble and assemble an extra time because of this.
Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Shelly from WATERLOO, IN
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The ice flapper would not go close .
remove the front of were the ice and water comes out
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from Littleton, CO
- Parts Used:
- WR23X31507
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The Light Would Not Go On
Knew the switch was bad. Researched on the internet how to fix. Used a steak knife to pop the old one out, changed the contacts to the new switch and popped it back in. It took longer to open the box than it did to replace the switch. And the part arrived 2 days after I ordered it.
Was this instruction helpful to you?
Thank you for voting!