Customer:
Martin from Mount Pleasant, SC
Parts Used:
WR17X11269
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The rubber ice deflector fell off becasue the funnel failed
After removing the front cover to the control panel, I removed the 3 connectors. Then I removed the 4 screws and pulled out the assembly with the funnel.

The I had to lift the plastic tabs on the left and right to release the funnel. Reinstalling the funnel was a little tricker, trying to get the two plastic tabs, the spring and the tab that works the switch all in place at the same time. Then I installed the rubber deflector onto the funnel (the original problem.)

Finally reinsert the assembly, install the 4 screws, attach the 3 connectors, slide the panel back into place starting at the top and then the bottom
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
D from ZELLWOOD, FL
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jamison from Heltonville, IN
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).

Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).

EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
richard from cleburne, TX
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
16 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherry from Auburn Hills, MI
Parts Used:
WR02X11330
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from Alamosa, CO
Parts Used:
WR60X10220
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Condenser Fan Motor stopped turning
1. Unplugged the fridge. 2. unplugged the fan connection and removed the wire holding clip. 3. removed the 2 screws holding the motor bracket in place and removed the bracket. 4. Pulled gently back on the motor so that the fan pressed against the front bracket until the fan slid off the motor shaft. 5. Pulled the rubber motor mounts off of the old motor and placed on the new motor. 6. Slide the new motor in place pressed the fan all the way onto the shaft. 7. Placed the rear motor bracket in place and started the screws by hand making sure the ground wire was attached to the furthest away screw. 8. tightened the screws down. 9. Pushed in the wire holding clip into the clip hole. 10. Plugged back in the fan. 11. Plugged back in the fridge. 12. Turned down the temp on the fridge to kick on the compressor and checked to assure the fan was operating and then set the temp back to normal. 13. Vacuumed the condenser coils to get them all clean and ready for more years of service!
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Williamsburg, VA
Parts Used:
WR17X22070
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
No longer needed water filters
Your website was very easy to use and the product shipped very promptly. It was great experience. Thanks!
22 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Hanford, CA
Parts Used:
WR01X10315
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Ice Maker auger blade broken
The ice machine auger blade broke a chunk off. I decided to try to replace it myself. I bought the new auger blade and then sat there and stared at it and the ice machine for a few, trying to figure out how to change out the part. Turns out it was a qute lengthy process. The auger is threaded on one end and the ice chopping blades are on it. So I had to take each blade off the old one and put it on the new one. The blades have to be positioned just right on the shaft so it's best to just draw a line down over all the blades so as to put them on the new auger successfully. The problem I had was the end cap that screwed on the end of the shaft. It was the part I ordered here. It is made of plastic with plastic threads and at first I couldn't figure out to get it off. Turns out the threads are opposite normal. By the time I figured that out, I had just about destroyed the cap using pliers to try to unscrew it. There is a washer and half moon clip that fastens on this end nut so if you mess the nut up, chances are you won't be able to get the half moon clip to go back on. I finally did it right and now how the ice maker working right again. A hard part for me was figuring out how to set the spring shaft that works a lever to either give cubed ice or crushed. I had to keep fiddle with it before I finally got that right. At first I was only getting crushed ice even with the cubed setting and then only getting cubed ice with the crushed ice setting. After some fiddling, I got both to work but to this day can't figure out what changes from the crushed setting to the cubed setting.
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from DOWS, IA
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Freezer Cold Refrigerator warm
The defrost heater failed. The coils frosted completely over so no airflow to the fridge. Step 1. Empty the freezer. Ice maker and top shelf can stay. Remove power, pull plug or open breaker. Step 2. Remove shelves and bottom food drawer. Step 3. Remove bottom food drawer rails. 2 phillips screws on each side. Step 4. Remove back panel, 2 screws at the top. Work panel out. Note there may be a green ground wire hook on it at the top. This will expose the heater and the cooling coils. The heater is at the bottom of the cooling coils and is the width of the coils. Step 5. There will be 2 wires, one on each end, and two phillips screws holding it in. Wires pull straight out. Note which way the heater is installed and remove the 2 screws. Step 6. Assemble in reverse order. Be very careful with the heater. It is in a glass tube and is very easy to break.
13 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
calvin from annapolis, MD
Parts Used:
WR62X10055, WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.
19 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Republican City, NE
Parts Used:
WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker door failed to close letting ice melt
Removed the front panel on the door that has the ice maker controls. Removed the screws and parts. Reassembled the parts and it works better than new. Ice door closes firmly and holds tight.
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cristina from Los Angeles, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sheila from Robeline, LA
Parts Used:
WR02X11941, WR62X23154
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
ice auger drive stripped out, solenoid burned out
removed ice tray, removed drive unit. removed solenoid and replaced, screwed on auger drive. reinstalled drive assembly. replaced ice tray. job done.
21 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
debbie from chino hills, CA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
18 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Spring, TX
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
"Moaning Myrtle" syndrome. Refrigerator makes a whooing sound for hours at a time
Checked the internet for reports of similar problems and concluded that it was probably the main control board. Not being particularly handy, I would never have attempted to change the board myself if I had not read the comments and instructions from people on this site. Thanks.

The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.

The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.

I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
13 of 15 people found this instruction helpful.