TFX22PLL General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Ed from Omaha, NE
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Refrigerator door wasn't self-closing; door hung a little lower than the freezer door
The old plastic door closer cam on bottom of the the door had broken. What was left of it was held on by a hex head screw. There was also a fiber spacer under the cam that was broken. I made a new one out of a piece of aluminum, but cardboard probably would have worked.
Forgot to mention you have to take the door off first--loosen the two screws on the top hinge and lift the door out of the bottom hinge.
I found the self-closing sometimes won't work well until there is some weight in the door.
Forgot to mention you have to take the door off first--loosen the two screws on the top hinge and lift the door out of the bottom hinge.
I found the self-closing sometimes won't work well until there is some weight in the door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Almont, MI
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refridgerator door not closing right
i'm glad I read this forum before ordering the part because you need two of the door cams. They're sandwiched together on the lower hinge.
I removed the top door hinge, lifted the door off from the lower hinge and layed it on the counter.
I then removed the lower hinge using a nut driver.
I had to grind the rivot head off that holds the door cam onto the hinge and use a nut & bolt to replace
the rivot.
I removed the top door hinge, lifted the door off from the lower hinge and layed it on the counter.
I then removed the lower hinge using a nut driver.
I had to grind the rivot head off that holds the door cam onto the hinge and use a nut & bolt to replace
the rivot.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lucky from Dacula, GA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator door would not close.
1. I removed the top door hinge.
2. I removed the door and laid it flat.
3. I replaced the cam attached to the bottom of the door. This was very easy.
4. I removed the bottom door hinge and had to remove the brad that held the second cam. This went well as I was able to saw it with a hacksaw.
5. Replaced the second cam with a bolt and nut.
6. Replaced the door and top hinge.
7. Remember to order two cams when you do this repair.
2. I removed the door and laid it flat.
3. I replaced the cam attached to the bottom of the door. This was very easy.
4. I removed the bottom door hinge and had to remove the brad that held the second cam. This went well as I was able to saw it with a hacksaw.
5. Replaced the second cam with a bolt and nut.
6. Replaced the door and top hinge.
7. Remember to order two cams when you do this repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Woodbury, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Refrigerator door would not close properly
I first removed all of the door contents. I then removed the door from its mountings by removing two screws at the bottom bracket. With the door lying on the floor I then removed the two screws holding the door cam assembly in place. I inserted the new door cam, then reversed the process replacing the four screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Washington, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Fridge door did no close and was out of alignment
Followed previous poster's steps. Replacement of door closing cams took 35 minutes. Make sure you buy 2 cams for each door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from Upper Malboro, MD
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Door would not shut by itself.
I followed the directions on the computer and everything went just as the video said it would. This was one of the easiest repairs I have ever done. Usually, it does not go as planned.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Neal from Cleburne, TX
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Door would not close properly
Removed the door and loosened the bottom bracket and scraped the old cam off. Mounted new cam and tightned the bracket. Replaced door and it was a total sucess.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- DAVID from NEWPORT, PA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Door would hang up half way closed
Replaced both upper and lower cam's. Removed door from refrigerator, removed bolts on door cam on bottom of main door and replaced cam, then removed bolts from door hinge assembly, drilled out rivet holding on cam, replaced with new cam and re-riveted.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles M from Concord, NC
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Door Closing Cam broke
The bottom of the door was 5 " off the floor. A 2x4 block and a 4x4 block were pushed under the door and supported it while the water line was disconnected the hinge removed and the cam replaced. It was a simple fix and reading other people's experience made the repair so much easier.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robin from North Plainfield, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
Door Cam And Cam On Refridgerator Were Damaged
I did not realize I needed 2 cams to complete repair. Door cam was riveted in. I had to drill out rivet and replace with nut and bolt. Otherwise it went quite sommothly. At first I just replaced the cam on bottom of refridgerator but door was not quite right when closing. Further inspection showed the door had the other half of cam that also needed replacement. Needed 2 orders. Paid for 2 shippings.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- gregory from ellerslie, MD
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
door was uneven and wouldn't close tight
removed the door, installed the cam riser, and reattached the door. It took longer to remove the contents in the door than it did to install the cam riser.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Myrna from Wyalusing, PA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
the cams on bottom of door wore out with age- 20 years
Replaced the old cams with new ones, door works perfect now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Springfield, MA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Door wouldn't close by itself. Cam part found on floor.
I removed two screws at the top of the door, lifted the door off. I got lucky: the broken cam was the one on the door (easy to remove), not the one on the body of the refrigerator (tough to remove).
There is a shim which was also broken - no way to know that ahead of time. I bent a 5/8" lock washer flat and it served acceptably as a shim.
It would be helpful if PartSelect.com could include with its listing of the cam, the fact that (1) the shim will probably be needed, and (2) there's a very good chance that you'll need TWO of the cams as well.
There is a shim which was also broken - no way to know that ahead of time. I bent a 5/8" lock washer flat and it served acceptably as a shim.
It would be helpful if PartSelect.com could include with its listing of the cam, the fact that (1) the shim will probably be needed, and (2) there's a very good chance that you'll need TWO of the cams as well.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eugene from Macedon, NY
- Parts Used:
- WR2X4901
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
door dropped when opening and wouldn't stay partially opened
removed top plate and raised the door off. I removed the L bracket from the fridge then noticed the part was rivited onto the L bracket. I cut the rivit and replaced the cam and used a small bolt and nut to sdecure it. Replaced the L bracket, the door, and the upper support. Only problem was the surprise rivit
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carmine from Millington, NJ
- Parts Used:
- WR17X2740
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Replaced corroded auger
Removed front cover, removed rear cover careful to note position of spring assisted parts, used pliers to unscrew auger rod end cap, removed and soaked in Lime Away fixed and movable blades. Reassembled using diagram on website for guidance.
Was this instruction helpful to you?
Thank you for voting!