PFS22MIWABB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- randall from coopersville, MI
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
refriderator not cooling consistetly
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lynn from MOUNTAIN HOME, ID
- Parts Used:
- WR30X10093
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Debbie from Tujunga, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
no cooling hrs display
I removed the board, unplugged all the sockets, took the new board, plugged in all the sockets, and replaced the new board into the refrigerator. I was to applaud this business. I was first able to diagnose the problem by finding this site, then one of the customers explained how to fix the problem ourselves. It save us at least $100. The $25 overnight shipping fee was well worth it. We could have lost $100's of dollars worth of food.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Akron, PA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Compressor Would not come on. Found the relay on the Main Board burned up. There was no electrical power to the compressor .
Ordered a new Main circuit Board. It arrived next day. Unplug the fridge to take away electrical power. Unscrewed the panel on the back of the fridge near the top. I then pulled the wire connectors off the circuit board. Gently pull the board off the plastic tabs. Push the new board onto the tabs. Reconnect the wire connectors. Screw the panel back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from Ellicott City, MD
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator ran too much, condensor fan not running
Removed cover plate on rear of unit - 3 screws
Removed connectors and ground wire
Removed board (use needle-nose pliers to compress plastic mountig posts)
Replaced board, inserted connectors, attached ground wire, put cover on
Everything worked properly
Removed connectors and ground wire
Removed board (use needle-nose pliers to compress plastic mountig posts)
Replaced board, inserted connectors, attached ground wire, put cover on
Everything worked properly
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Philip from Los Alamos, NM
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Cabinet very hot on sides, freezer not 0, running continuously.
Diagnosis of symptoms was condenser fan not running, due to faulty main board.
First: removed the cover over the main board, which was too hot to touch. Bad design flaw, no ventilation for the board, which I believe made it fail. We got another year of service with the cover removed.
Second: after reading people's experiences here, ordered the board and popped it in. (Note: needed a pliers to compress each of the 4 plastic studs holding the board in.) Works like a champ.
Third: did NOT replace the cover. At our altitude the air can't conduct enough heat to prevent cooking the board. Need to allow circulation.
First: removed the cover over the main board, which was too hot to touch. Bad design flaw, no ventilation for the board, which I believe made it fail. We got another year of service with the cover removed.
Second: after reading people's experiences here, ordered the board and popped it in. (Note: needed a pliers to compress each of the 4 plastic studs holding the board in.) Works like a champ.
Third: did NOT replace the cover. At our altitude the air can't conduct enough heat to prevent cooking the board. Need to allow circulation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Barrington, IL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Freezer never kept a consistant temperature. One night heard a clicking noice which was followed by the temperature display showing temps like -31. Researched to find other with the same issue and ordered the replacement board to repair.
I must admit - I thought I'd attempt to do this repair and end up calling a service guy to finish it. I'm not mechanically inclined AT ALL but thought I'd give it a shot after reading others experiences. I'm glad I did. The fix was easy, but there was initial anxiety while reading the instructions that came with the part - as they mentioned the possible need to cut some wires. Fortunately that was not necessary..... Removed three screws from the rear plate to expose the part needing to be replaced. Remove the fittings from the old board (needed plyers to do that - be gentle), take the old board out by using needle nose pliers to squeeze the white plastic tabs and pull the board free. Reconnect fittings to new board and you are done. Works better now than ever - obviously the old board had an issue that GE should have recalled, as many others had the same problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from SCOTTSDALE, AZ
- Parts Used:
- WR55X10025
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rickey from DUMAS, AR
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugged it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from Callaway, FL
- Parts Used:
- WR30X10093
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Ice maker arm disconnected from frame causing problems.
The icemaker arm disconnected from the metal frame. This caused the icemaker to cycle and the heater to come on and stay on until the plastic parts melted causing a mess and stink. This action melted the ice and then the water fell through the frozen items in the freezer and refreezed in the lower portion. OK, I remover the dead icemaker and tossed it away. I installed the new icemaker and the wiring harness didn't fit right (way to long). I retrieved the old icemaker and removed the wiring harness from it. I removerd the new ice maker and installed the old wiring harness to the new icemaker. I then installed the new icemaker, plugged it in and turned on the power. No water, I ordered the dual solenoid water valve, installed it with difficulty (another story) the turned on the power. I reinstalled the ice bin and found it didn't fit. The icemaker was to low and couldn't be adjusted, 1/4" higher would have been great. I shoved in the bin anyway, I was out of ice for my scotch, and it started making ice.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rene from HEBER, CA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
condenser icing refrigerator warm freezer ok
follow the easy instructions replace 3 temperature sensors cut the wires and crimp them with new sensor and it works like new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from West Winfield, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
The fridge was making a clicking sound, and not cooling the food
The back panel was unscrewed, we read the directions with the circuit board and followed them. It was very easy to unplug the old faulty unit and plug in the new replacement part. It was done in 4 minutes flat. Very easy to do yourselves!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- james from vista, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Making an owl sound from the icemaker side
Simple; Removed the panel, unplugged the cable connections to the mother board with a rat nosed plier.
Then to remove board you must squeeze closed the 4 plastic retainer clips in each corner, or they can accidentally be pulled off with the board.
Removed the board, re-attached the new board on the clips, then the cable connectors, then the panel.
Plugged in the refrige and it has been silent ever since.
Follow the instructions and anyone can do it.
Then to remove board you must squeeze closed the 4 plastic retainer clips in each corner, or they can accidentally be pulled off with the board.
Removed the board, re-attached the new board on the clips, then the cable connectors, then the panel.
Plugged in the refrige and it has been silent ever since.
Follow the instructions and anyone can do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ted from Harrisonburg, VA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
icemaker stripper fall a part
instalation was very easy - but the part was 3/4 inch to long and a 1/32 inch to wide.Trimmed it with the "faithfull"
Dremel and it works!The instalation part of the "job" was less then 10 min.
Dremel and it works!The instalation part of the "job" was less then 10 min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Glenn from PORT JEFFERSON, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ghostly Sounds From Fan Motor - Variable Speeds All Night - Motherboard Problem
Simple directions were provided. It took more to clean and vaccuum than the actual repair. Yes I replaced the motherboard in a referigerator. Just keep not of the connectors and were they came off from on the original board. Dont just rip them off because the new board has some different connections. So follow the directions and take your time if your not sure. But really it a cinch. No more whoooo sheeesh and howling noises from the referigerator. Thank goodness.
Was this instruction helpful to you?
Thank you for voting!