Customer:
kenneth from west chicago, IL
Parts Used:
WR17X2062
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice-maker grinding faceplate heavily rusted causing rusty ice
Disassembled ice-maker, noting what screws went where, what direction ice release control arm pointed, and noting how the control arm spring was mounted. The door assembly comes off first followed by the circular assembly that houses the ice door and last grinding arms. It is quite easy see how it comes apart as you look at the screws. Remove the screw holding the back end of the control arm and note the spring position. The control arm needs to be turned to line up notches to pull it thru a faceplate hole while rotating the arm about the "U" that is on the outside of the faceplate in the door housing. There is a retaining clip holding the rotating impeller to remove to complete the dis-assembly. Use vinegar to clean rust out of bin and other parts around the faceplate. Assemble the unit in the reverse order to complete the job.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Rockford, IL
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
heavy frost buildup in ice dispenser chute and door
After inspection of the new door recess assembly, I realized that I could use sidecutters (electronic assembly type) and 'clip' off the inward lock tabs of the old recess assembly and disengage it from the crank door arm without any further disassembly of the refrigerator door. It was easy to 'unhitch' the tang from the crank arm and wiggle it out through the external opening of the ice/water dispenser compartment. I reversed the process and inserted the new assembly through the external opening of the compartment. The new door recess assembly snapped into place on the crank arm and fit tightly against the ice chute opening, correcting the issue caused by aging distortion of the old rubber seal cup portion of the door recess assembly.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from Genoa City, WI
Parts Used:
WR17X4358
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
The dispenser water reservoir had a pin hole leak.
1. Turned off the water supply to the refrigerator.
2. Removed the front panel and disconnected the water line to the front left.
3. Removed the left rear (freezer side) panel and disconnected the reservoir from the main water supply input. This was a little tricky to figure out. You must push in the water line at the same time pushing in the coupling. Then pull the line out while keeping the coupling pressed in.
4. Removed the screw that holds the reservoir to the back of the refrigerator.
5. Pulled the old reservoir out and replaced it with the new one.
6. Basically the rest is the reverse of the above. It took a little bit to fish the lines through the original path they came.

Overall this was an easy repair. If I had known how the coupling in step 3 worked this would have been a 15-minute project.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Catherine from SEATTLE, WA
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.

No tools needed, the cap is just held in place with pressure from the wire.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Danbury, TX
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker Auger and ice was rusty.
Pull out the old, dump the nasty ice. Remove 4 screws attached to the front cover. throw in trash, replace with new auger assembly, with 4 screws. Put it back in ice maker and let it make ice. Easy, cheap and never left the house to searc for the right part, found it on the front porch.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Cumming, GA
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken Light Shield
Removed the Ice Maker container. Removed the one screw that held the remnant of the old light shield. Placed the new light shield in place and installed the screw. 5 Minutes from start to finish.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from WINTERVILLE, GA
Parts Used:
40A15
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
6 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
PAUL from ALBUQUERQUE, NM
Parts Used:
WR17X3489
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
LIGHT SHEILD BROKE.
SNAPPED THE NEW SHIELD IN PLACE. DONE!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Angel from Chandler, AZ
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice was discolored due to rust on auger
Removed the old assembly from the refrigerator. Used a screwdriver to remove the four screws attaching the old assembly to the plastic front plates. Opened the box holding the new part (which had arrived very promptly at our doorstep), removed it and attached it very easily to the plastic front plates using the same four screws. Placed the new assembly in the refrigerator and started making new ice. It was EASY!! We had read what others had said about this repair and knew it would be something we could do. Your website is very user friendly and helpful.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cindy from Yorba Linda, CA
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
making rust in ice
This is the easiest thing in the world - thanks for sharing other's installation - it took 5 mins - works perfect & we have clean ice - 4 easy screws to remove - anyone can do it!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raymond from Niverville, NY
Parts Used:
WR17X2740
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Blade on auger became stripped
Ordered at PartSelect and received the auger and blade within days. Printed the parts diagram and proceeded to take the auger apart the time it took would have been much less but I seized the opportunity to do a deep cleaning of the old parts before replacing them....The part diagram was the key to simplicity and the fast shipping was awesome. Thanks I'll be back....
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Union, NJ
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The freezer light shield was broken.
I removed the ice maker,removed the broken piece of the old light shield,screwed the new light shield in place,and replaced the ice maker.It took all of 5 minutes.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roger from Colleyville, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Travis from Hillsboro, OR
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light Shield Broke Off
The light shield is only held in with a single screw, so it was the simplest install ever - unscrew the old light shield (in my case, the remaining piece of the light shield), put the new shield in place, and screw it down. Doesn't get any easier than that.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
bryan from miamif, FL
Parts Used:
WR17X4312
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
ice maker was rusty
i ordered this ice maker on sunday night and paid for the cheapest shipping. it got here monday morning and i couldnt believe it. super fast shipping!! works great
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!