- Customer:
- Jodi from Benton Harbor, MI
- Parts Used:
- WR23X37285
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paypal_shipping_address from Ripon, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Darren from Riverside, CA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Socket set, Wrench set
was not able to get water out of the dispenser or the ice maker
Very simple fix. Just remove the back cover, unscrew the water valve, unplug the water valve and disconnect the water line. Then reinstall the new one. Takes about 15 to 20 min and it worked like a champ
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gregory from The Villages, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
Water dispenser inoperative
Replaced Double Outlet Water Valve then defrosted coiled plastic water tubing at bottom position inside refrigerator into pan of hot water for 10 minutes. Water still did not flow. Defrosted refrigerator and water dispenser immediately resumed operation. Suggestion -
defrost refrigerator first.
defrost refrigerator first.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- david from torrington, CT
- Parts Used:
- WR50X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
freezer worked but thelower part where the milk and the fruit are was warm checked on your site to get help and you were on the money with telling me it was the thermostat i orderd it and it solved the problem thank you.
i took the backing off with a screwdriver, cut the wires and put the 2 wires on that came with the thermostat. p.s. make sure you pull the power plug before you start.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter M. from Lincoln Park, NJ
- Parts Used:
- WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Stewartsville, NJ
- Parts Used:
- WR57X33326, WR02X11330
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench set
water leak from water line and value housing
Unplugged unit. Removed back cover plate. Used 5/16 water line. Cut old broken line. Used water tube union and attached new line. Removed electrical contacts. Note very easy removeand replace the red and white hookups. Next remove water line at the old vale with1/2 wrench. Hook up water line to new valve. Icemaker line was not damaged so I removed from old valve and trimmed the end. Really installed line to valve. Plugged in fridge and turned water supply back on. Check for leaks. Had trouble locatingthe 5/16 water line but found bulk. PARTS SELECT had the guest connector and the replacement valve. I received the correct parts and saved me $$$$. Plus my wife happy right before the holidays! !!,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from ROSEMOUNT, MN
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Wyckoff, NJ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker stopped making ice
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from BOZEMAN, MT
- Parts Used:
- WR02X12008, WR02X10540
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Noisy Freezer Evaporator
Find a video on youtube. Remove 6 screws. Pull the Styrofoam part up before removing the panel. Unplug and Remove the fan assembly.
You will need a NUT DRIVER to take the bracket off the backing plate.
I ordered the red grommet and the red bumper. You need TWO of the red grommets if that is the problem. My freezer was about 8 years old, and the grommets were worn and compressed, the bumper was not. Replacing these parts DID NOT FIX the problem. I needed a new motor.
I probably disassembled and reassembled this stuff about 7 times before I got all the parts and tools. Each time I had to unload the freezer.
You will need a NUT DRIVER to take the bracket off the backing plate.
I ordered the red grommet and the red bumper. You need TWO of the red grommets if that is the problem. My freezer was about 8 years old, and the grommets were worn and compressed, the bumper was not. Replacing these parts DID NOT FIX the problem. I needed a new motor.
I probably disassembled and reassembled this stuff about 7 times before I got all the parts and tools. Each time I had to unload the freezer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kevin from Charlotte, NC
- Parts Used:
- WR50X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Freezer was cold but fridge was warm. Coils in the back of the freezer were getting frosted. Defrost Sensor was broken
-Empty the freezer
-Take the cover in the back of the freezer off
-Melt the ice off the coils (heat gun, hot water, etc.)
-Cut the wires off the old sensor and connect the new sensor using a soldering iron or some other method.
-Cover the spliced wire with heat shrink, electrical tape or some other method.
-Reassemble the cover
Done!
-Take the cover in the back of the freezer off
-Melt the ice off the coils (heat gun, hot water, etc.)
-Cut the wires off the old sensor and connect the new sensor using a soldering iron or some other method.
-Cover the spliced wire with heat shrink, electrical tape or some other method.
-Reassemble the cover
Done!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from BURNEY, CA
- Parts Used:
- WR02X11331
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Socket set
Loud Squeal when fan was running
WE (WIFE) took out the old parts an replaced with new one ..Be careful to get the placement of the Grommet or they "POP" out on you. fast ship on the parts too.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Doug from Madison, WI
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set, Wrench (Adjustable)
Opend freezer door and found ice everywhere from dripping ice maker. Even with power unplugged water was still leaking through so I determined it must be the water valve at the back of the fridge that had failed.
Unplugged fridge. Shut off the water supply valve under sink. Removed lower access panel at back of the refrigerator (six screws). Removed single green screw holding water valve bracket and pulled assembly out to access wiring and hoses. It is a dual valve as one valve is for the water dispenser and one is for the ice maker. Disconnected the 2 electrical connectors (one for each valve). Unscrewed the compression fitting for the water inlet with 1/2 " wrench. Then the two water lines on the outlet which are quick disconnects. You must push the ring towards the valve and then the tubing can be pulled out by hand.
Reattach everything to the new valve and install and its ready to use.
Reattach everything to the new valve and install and its ready to use.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from GREENSBORO, NC
- Parts Used:
- WR02X12008
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Fan was not centered in the middle of the back panel opening.
Bent the motor bracket down, then using a rat tail file, elongated the holes in the back panel of the refrigerator to secure the fan in the "centered" position. This was a problem that was with the refrig. since it was made. The parts involved were perfect. NO problem at all installing them.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from BRADENTON, FL
- Parts Used:
- WR50X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Evaporator coil freeze up
Up plug from wall removed rear access cover in freezer let thaw out and replace two wire sensor had previously checked out knowing the defrost strip was good and the defrost thermostat was visually deformed and tested open at freezing and 40 degrees
Was this instruction helpful to you?
Thank you for voting!