ESC23KSTESS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Leif from Jacksonville, FL
- Parts Used:
- WR17X11168
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Intake hose to ice maker broke
After shutting off the h2o, I unplugged the refrigerator. Using the nut driver, I removed the cardboard backing. Then I removed the fitting where the inlet line to the ice maker and pried the old tubing from the unit. I then undid the clasp about 1/2 way up the back and removed the section that went through the back to the ice maker.
I then reassembled everything and plugged in the refrigerator as well as turning on the water.
Keep in mind that because h2o and electricity are involved. MAKE SURE THERE ARE NO h2o LEAKS.
I then reassembled everything and plugged in the refrigerator as well as turning on the water.
Keep in mind that because h2o and electricity are involved. MAKE SURE THERE ARE NO h2o LEAKS.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kyle from LAPWAI, ID
- Parts Used:
- WR17X11168
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Wasn't making ice
1. I unplugged the refrigerator/ freezer
2. Turned off water supply
3. Removed the screws that held the cardboard skirt in place
4. Unplugged the water tube from the push connect
5. Removed the screws around the water inlet to the ice maker
6. Remove the water fill tube
7. Install new water fill tube and put all the screws and plates back where they go
2. Turned off water supply
3. Removed the screws that held the cardboard skirt in place
4. Unplugged the water tube from the push connect
5. Removed the screws around the water inlet to the ice maker
6. Remove the water fill tube
7. Install new water fill tube and put all the screws and plates back where they go
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clyde from RIALTO, CA
- Parts Used:
- WR60X24484, WR60X10209
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from THE VILLAGES, FL
- Parts Used:
- WR49X10228
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Water/Ice Dispenser worked sporadically.
I used the video Parts Select referenced on YouTube, which showed a technician doing the repair. In my particular instance I did not need to remove the escutcheon around the dispenser using a putty knife or remove screws from underneath. There are two tabs in lieu of the two screws that I used a Phillips screwdriver on to push in which released the control panel. It went just as the video showed w/o a hitch. I'd like to add that this is the second time I've used Parts Select for a different appliance and thank God for their showing you what the part looks like and the videos, it helps bolster your confidence to do the repair correctly! I only wish there was more sites like this.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bert from SAN JOSE, CA
- Parts Used:
- WR60X30922
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little retaining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Liberty, MO
- Parts Used:
- WR55X10942C, WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
My refrigerator/freezer had several problems; both frig and freezer wasn't cooler properly, some days everything froze. The ice maker stopped making ice and water was leaking in the freezer.
I first called a GE repairperson. The diagnose the problem and told me the main control board was shot and the double outlet water valve needed replaced. The estimate for both parts and repairs was $850.00. I thought the estimate was high so I did some research on-line and discovered I could purchase the parts myself. When I researched the part, a short video popped up explaining how to install the part. I watched both video's and did exactly what the guy in the video said and was able to repair my refrigerator/freezer myself. The total cost for both parts was $200.00, I save $650!!! Amazing. I ordered the part on Saturday, and was told it would take a week to 10 days to receive the part and the part showed up on my door steep the following Tuesday. I'll never call a repairmen first again. I'll research the issue through partselect.com and try to fix the problem myself. I am not technologically or mechanically sauvy and have spent thousands on repair bills in the past, no more will I do that.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Helotes, TX
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
Ice build up behind ice maker ,water chute frozen up
Unplugged ref.,turnned water off at wall and drained, removed back cover on lower part of ref. then removed screw holding water valve,unplugged both wires from unit,pulled the 3 water lines off,1 I had to cut, would not release,got new water valve,push 3 water lines in place,attached the 2 wires in place and screwed unit back on ref.and replaced back cover on ref. Then I got a hair dryer and thawed all ice that had built up behind and under ice maker in freezer,cleaned that mess up,turned water back on plugged in ref. All good ,repaired problem,old water valve was bad.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tim from Mountain View, AR
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Ice cream melting, lettuce freezing
Removed the back cover over the control board, and made sure that the board was the same. It didn't look exactly the same, but figured that it was the same, just updated. Took out the board, moved the wires to the new board and reinstalled. Plugged it in and it came on, so I reinstalled the cover. Seems to be working to this day.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- G Michael from MONROE, OH
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench set
No water out of refrigerator but had ice
Followed the video showing how it was done. Took me longer to go to the basement and shut the water off and on, than it did to replace the valve
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Longwood, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
No water dispensed from door tap, icemaker OK
The problem was both the valve and a frozen slug of water in the supply line located inside the door. After replacing the valve, I turned the freezer to a setting of 1 and in about 30 hours, water flowed out the tap.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Lawerence, MI
- Parts Used:
- WR17X11505
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice would fall after removing glass.
I took the ice drawer out and turned it upside down. Then removed two philips screws holding the drawer front on. Then with a small straight edge screwdriver pry out the sides to release the locking tabs and remove the auger and crusher assembly. Then on the end of the auger remove the e-clip, slide the auger out and remove the broken part of the crusher dispenser and replace with new. Easier than it sounds. Parts Select was great to deal with. Had my parts in two days.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Tiverton, RI
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Freezer/Fridge not cold & compresser would not turn on.
For troubleshooting, I took off rear panel inside of the freezer compartment & determined that icing of the coils was not the problem & it did not apprear to be a defroster malfunction. All components appeared to be working properly except the compressor would not turn on and only room temperature air was being circulated by the fan. After narrowing the probable causes down to a faulty Main control board by reading as many similar posts as possible,I ordered the new control board. When it arrived the following morning via UPS(less than 24 hours!), I unplugged the wiring connections attached to the old board, (which was somewhat different in appearance), and then gently popped the circuit board off of the plastic retainer studs by pushing in the little retaining clip part of the studs in with a small screwdriver so the board could be released easier as I pulled outward. I popped the new board on the studs by gently & evenly pushing with a larger hut driver over the studs until it was locked in, being careful not to damage or over stress/bend the board. I placed the wiring connecters onto the pins on the board.....every connecter had a different amount of pins so improper connection was not possible. I placed the ground wire connection of the new board between the metal cover plate @ an adjacent screw location to ensure grounding to the back of the fridge sheet metal. I plugged in the refrigerator and was quite relieved when I heard the compressor start up after a second or two! Within moments the temp began to fall until it reached the proper temp in both compartments. Success!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Theodore from Carteret, NJ
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Water Leak behind Refrigerator
Shut water behind the refrigerator, unplugged the unit. Unscrewed the back tin panel and simply unscrewed the brace scew for the Double Outlet Water Valve. Disconnected the hoss - inspected the hosed for wear. Next detached the hoses and power source to the unit... reconnected both hoses & power source, plug the refrigator back in and inspected for any water leaks. Simple!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Georgetown, TX
- Parts Used:
- WR23X10783
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Water dispenser not dispensing water
I went to the internet and found parts select web site. Saw all of the possible fixes for my problem and read all of the other repair stories. My story actually became a journey that is still continuing. I first changed the water filter, but still no water at the dispenser. I next disconnected the coupling at the bottom of the freezer door that carries water to the dispenser and when the dispenser was depressed, water flowed at the coupling, but not at the dispenser. After reconnecting the coupling, I turned the freezer setting to 1 for 4-5 days, but still no water at the dispenser (possibly the line was frozen, but we had recently been away for a week and the water dispenser still supplied water at a freezer setting of 4). Now I am at the point of the journey into replacing parts one at a time to get water. First I ordered the dual water valve for the ice maker and water dispenser. I replaced this valve with instructions from Parts Select and still no water at dispenser. Next I ordered and replaced the switch at the dispenser lever and still no water. Next was the solenoid attached to the ice door, ordered, replaced and still no water at dispenser. I am now at the final part in this repair and that is the $132 circuit board. So I will be ordering this part soon and hopefully that will fix the issue.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- lam from JACKSONVILLE, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Dual Inlet Water Valve
Just fallow video shows that it 123 !
Was this instruction helpful to you?
Thank you for voting!