Customer:
scott from Reseda, CA
Parts Used:
WR60X35205
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Bottom Drawers started to freeze
Replace fan . Fairly easy.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from ROSEMOUNT, MN
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from NORMAN, OK
Parts Used:
WR02X23032, WR11X10031
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
COVER LATCH BROKEN
I recieved the package with the correct part number but the wrong part inside. The item in the package does not even resemble the part on the GE parts website. Tried to contact parts select but no luck.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Greg from ANKENY, IA
Parts Used:
WR32X10910
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The middle support for the vegetable door roller wheels broke
Removed drawers, lifted out old frame assembly ( no tools ) removed and cleaned old glass from assembly.
Carefully screwed old rollers ( x4 )into new frame, then placed old glass in new frame, repositioned frame into refrigerator and then repositioned drawers in frame.
20 minutes , no issues
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from COLUMBIA, SC
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tommy G from Matthews, NC
Parts Used:
WR49X10322
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
The ice maker worked great and the crushed ice dispenser worked fine but the cubed ice dispenser sounded like it had a stripped gear.
Once I opened the left hand door and removed the ice bucket, I simply removed the 3 small screws and removed the old part and replaced it with the new part.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from Salisbury, NC
Parts Used:
WR71X11045
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
I dropped The top left bin and it cracked
Popped it up and popped new one on
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from LAKE PLACID, NY
Parts Used:
WR71X11063
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Replace butter compartment on GE Profile
It just snapped in. Fit perfectly. Excellent service.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
elissa from ASHBY, MA
Parts Used:
RPWFE
Difficulty Level:
Very Easy
Total Repair Time:
More than 2 hours
Replaced thermistor 5.2 ohms of resistance
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
QUOC-LOC from LYNN HAVEN, FL
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kent from Bartlesville, OK
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sara from White Plains, NY
Parts Used:
RPWFE
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Water filter needed changing.
Snap filter into place while holding the filter slightly away from the refrig. When filter snaps into place, push it towards refrig into place.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Pasco, WA
Parts Used:
WR07X10131
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
compressor motor wouldn't start, so no refrigeration
My brother-in-law is a 15 year refrigeration technician who I called and described the problem to. He told me to put an "amp clamp" on the line side of the wires (black) that go to the starting controls on the side of the compressor. The motor has a label that has a number on it (LRA) that he used to determine the max amps it would pull. In this case, if the motor pulled 10 amps, then the motor was bad and I'd have to buy a new refrigerator. It was pulling less then 9 amps so he thought to buy a new overload, since the capacitor checked out (measured by multi-meter). As soon as the part came, I removed the back panel (4 screws removed by nut driver), removed the clip that holds the overload/capacitor assembly, detached the two wires from it, and removed the capacitor from the overload. I swapped in the new overload and repeated the above process in reverse. The only difficulty was that the new part was different in that the plug-in locations for the two wires were in different locations, and not marked. I had to disassemble the old part to figure out how it worked so I could deduce how the new one plugged in. Once that was solved, it was a quick fix. This was not a repair that just anyone could do; it required someone with a lot of experience to help me, and I am an engineer.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Island Lake, IL
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
frige too cold
changed sensors did not repair problem,replaced damper with mechanical damper fixed problem.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from silver bay, MN
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Fridge Side Freezing/Too Cold
Followed the repair video, was spot on!!
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CYE22UP2MJS1