Models > GSH25VGRACC > Instructions

GSH25VGRACC General Electric Refrigerator - Instructions

Jump to:

All Instructions for the GSH25VGRACC
46 - 60 of 1240
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
John from Dexter, MO
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Water leaked constantly from water dispenser in door
Had to turn off water and remove back panel and with a few tools the part was off and the new part put on in less that 30 minutes!! Finding parts on your website were easily found.
22 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from Anderson, SC
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
I had a water leak (undiscovered) from under my refrig
After de-energized unit (by removing electical plug from outlet),I removed the rear panel at bottom of unit. I then removed the mounting screw to the water valve. I then disconnected the wiring assembly from the old unit. I then removed the water supply lines going to the icemaker and water filter. I then placed the water supply into the replacement water valve. plugged in wiring assembly to new unit and rehung water valve inside refrig. Turned water valve on at water supply to check for leaks, finding none I then replaced back panel on refridge and plugged in electrical cord and returned refrige to normal place in kitchen.
22 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leonard from Keller, TX
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Main circuit board wouldn't allow the compressor to come on
Removed old circuit board and replaced with new
22 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Pretty Prairie, KS
Parts Used:
WR60X10074
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Fan was noisy and finally quit. Top of freezer was 50, bottom of freezer was freezing.
First I removed the top shelf, ice drawer and second shelf. Next, I used a 1/4" socket and removed the three screws holding the ice maker lower unit, unpluged and removed from unit. I removed the light cover revealing two screws. I then removed the plastic unit holding the fan. I unpluged all plugs and uncliped the white sensor from the back coils. Once the fan was out, I replaced it with the new one by unbolting the fan bracket and putting the new one in place. I clipped the new sensor in place and replaced all the parts in reverse order. I saved $200 in repair costs thanks to PartSelect.com.
25 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Windham, NH
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers, Socket set
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
23 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jania from Novato, CA
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
26 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Curtis from Corona, CA
Parts Used:
WR23X10783
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Water dispenser won't always dispense water
I followed the instructions found on this website. I removed the control panel by inserting a small Phillips screwdriver in the three holes at its bottom. I used the same screwdriver to pull the dispenser assembly down but could have used a larger one. The microswitch could be seen in the assembly at that point and was easily removed by opening the "fingers" that held it in place. I attempted to pull one of the terminals off without using a pair of needle-nosed pliers and ripped the wires right out of the terminal(I was able to find a replacement at Radio Shack). Low and behold after reinstalling the new part, it did not take care of the problem.

My problem is the water dispenser does work intermittently. When we place the glass in position and hit the lever, the lights in the control panel go off and no water is dispensed. My next guess may be the water valve or the control panel. The icemaker makes ice but I have had problems with it dispensing for nearly a year now.
27 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephanie from Tampa, FL
Parts Used:
WR71X38317
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Dairy Door Cover had cracked
Repair took about 5 seconds. No directions necessary. Super easy.
21 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Chandler, AZ
Parts Used:
WR02X45206
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Cracked Housing Mount - water leak
Turned off the water. Removed the maintenance cover plate on the back of the refrigerator and disconnected the tubing. Removed the tubing cover plate on back of refrigerator. Removed two screws from filter hosing mount on the inside of the refrigerator and pulled the old tubing out. Simply inserted the new tubing and mounted the housing and reconnected the tubing using plumber’s pipe compound. Then re-installed the cover plates on the back of the refrigerator, installed the filter and turned on the water. It was a very easy install.
19 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
kevin from summerville, SC
Parts Used:
WR02X45206
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
low water flow from in door water dispenser
after changing the water filter and having no improvement. I went to the next part of the system. Turned off the water supply. I removed the bottom cover in the back of the refrigerator. unscrewed the nuts on the water supply hose from the main supply and the one going back into the fridge. moved to the inside of fridge and unscrewed two screws holding the filter mount and pulled the tubing through. Reversed my steps and the water flow was great . Thanks
17 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
D from ZELLWOOD, FL
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Martin from Mount Pleasant, SC
Parts Used:
WR17X11269
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The rubber ice deflector fell off becasue the funnel failed
After removing the front cover to the control panel, I removed the 3 connectors. Then I removed the 4 screws and pulled out the assembly with the funnel.

The I had to lift the plastic tabs on the left and right to release the funnel. Reinstalling the funnel was a little tricker, trying to get the two plastic tabs, the spring and the tab that works the switch all in place at the same time. Then I installed the rubber deflector onto the funnel (the original problem.)

Finally reinsert the assembly, install the 4 screws, attach the 3 connectors, slide the panel back into place starting at the top and then the bottom
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jamison from Heltonville, IN
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).

Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).

EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Hanford, CA
Parts Used:
WR01X10315
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Ice Maker auger blade broken
The ice machine auger blade broke a chunk off. I decided to try to replace it myself. I bought the new auger blade and then sat there and stared at it and the ice machine for a few, trying to figure out how to change out the part. Turns out it was a qute lengthy process. The auger is threaded on one end and the ice chopping blades are on it. So I had to take each blade off the old one and put it on the new one. The blades have to be positioned just right on the shaft so it's best to just draw a line down over all the blades so as to put them on the new auger successfully. The problem I had was the end cap that screwed on the end of the shaft. It was the part I ordered here. It is made of plastic with plastic threads and at first I couldn't figure out to get it off. Turns out the threads are opposite normal. By the time I figured that out, I had just about destroyed the cap using pliers to try to unscrew it. There is a washer and half moon clip that fastens on this end nut so if you mess the nut up, chances are you won't be able to get the half moon clip to go back on. I finally did it right and now how the ice maker working right again. A hard part for me was figuring out how to set the spring shaft that works a lever to either give cubed ice or crushed. I had to keep fiddle with it before I finally got that right. At first I was only getting crushed ice even with the cubed setting and then only getting cubed ice with the crushed ice setting. After some fiddling, I got both to work but to this day can't figure out what changes from the crushed setting to the cubed setting.
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Simi Valley, CA
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
19 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!