Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Jennifer from Fircrest, WA
Parts Used:
WR32X10381
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The original shelf was out of square. I tried to adjust it a little and one of the brackets broke off.
I removed the original shelf, took the glass portion off of the bracing and installed the replacement. The replacement was square and fit just fine so I installed it, put the shelf back on top and it works fine.
It was so easy to order the part through here. There were picture breakdowns so you could see exactly what you needed and order the correct part.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
louis from floral park, NY
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
evap fan not working.
first i removed the three screws that covered the circuit board that was bad. then i removed the 6 connectors that went from the refrigerator to the board then popped out the old board , popped in the new board reconnected the circuit connectors covered everything back up and my refrigerator is back on line. this all took about 10 to 15 minutes time ... thank you for your product it really did the job..
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Summer feild, FL
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
cold water dispenser would not stop running
Turn off the water.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bob J from Platte City, MO
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Water not dispensing
Background: My refrigerator was part of the class action law suit back in 2006. As a result both doors, the auger in the ice maker and a heating element in the freezer were all replaced.

Problem this time: Water was not dispensing.

Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.

Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.

However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Albert from Fort Wayne, IN
Parts Used:
WR51X10101, WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Defroster heater burned out
First I defrosted the evaporator core with a hair drier, making sure to disconnect the power before hand. I pretty much followed the directions included with the part, which by the way were excellent, and very detailed. The alternatives were call a repair man for around $300.00 plus parts or take less than a $40.00 gamble. Or even replace the refrigerator at $1400.00. It was the diagnostic portion of your website that convinced me that I had found the problem and that I could repair it myself with a minimum of effort. Needless to say I will come to this site in the future before calling a repair person. The refrigerator is working just fine now. I had my parts in three days, thank you for your attention to detail and a all around positive repair experience. George Day
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from White Pine, TN
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Would not cool top or bottom
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.

Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
nancy from Mt. Washington, KY
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
Was not getting water to the door.
Moved refrigerator out from wall, unplugged from electric, removed plate at bottom back with 1/4 nut driver, turned incoming water valve off, disconnected water line from water valve on refrigerator, removed mounting screw, remove water lines from valve and electrical plugs, set old valve aside and replace with new valve, reconnecting water lines and electrical plugs then remount bracket, reconnect water line from source, open water valve and check for leaks, replugged refrigerator and depressed the door button to check to see if working. It worked and there was not any leaks. Replaced back plate and placed refrigerator against wall. Job completed.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Sylva, NC
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Ice cubes froze in the tray and frost was all underneath
I read stories from the website how others did it so I figured I would give it a try. I put all the frozen stuff in the refrigerator piled up. Took out the shelves. Took out 2 screws with a socket extension ( nut driver will work fine.) Remove the light bulb. lifted up on the back panel...it came right out. Saw the coils and on top the sensor. Took it off, cut the wires, spliced in the color coded new one ( pink to pink, orange to orange) Stuck it in the top coil in the original position and crossed my fingers! I put all the pieces back easily, restocked the freezer and waited. HOORAY!! My ice cubes are all separate and free. NO frost inside. A very easy fix for $20.

Note: If there is a large amount of ice build up on your coils a hair dryer works great. The drain is on the bottom anyway. Also , you may want to seal around the wire nuts to keep moisture out. I did
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Seaford, NY
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Freezer stayed cold but Fridge got warm every 3 weeks
Unplug the fridge, then:
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and place a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed

I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.

Thank You PartSelect!
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Sweet Home, OR
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
evaporator coils iced up causing no cooling in freezer or fridge.
First I disconnected the Power from the unit. Pulled out the freezer drawers and the ice machine used a 1/4 inch nut driver and removed the sheet metal from the back of the freezer exposing the evaporator coils. I defrosted the coils. Then I removed the two screws holding the defrost heater braket assembly and removed the two electrical connections from it. I then installed the new heater put everything back together(reverse of installation)and it works like a brand new fridge and freezer.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kyle from LAPWAI, ID
Parts Used:
WR17X11168
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Wasn't making ice
1. I unplugged the refrigerator/ freezer
2. Turned off water supply
3. Removed the screws that held the cardboard skirt in place
4. Unplugged the water tube from the push connect
5. Removed the screws around the water inlet to the ice maker
6. Remove the water fill tube
7. Install new water fill tube and put all the screws and plates back where they go
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alex from Tampa, FL
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Water not dispensing
Moved refrigerator forward, this allowed me to work on the back panel. Unplugged the refrigerator power cord. Released all 6 screws, removed panel then release an additional screw that was holding the water valve and the two (red & blue) connectors. Then installed the new part in reverse steps. Plug the unit and job well done. I had purchase the water filter already after several minutes push for water from the dispensing front part of the refrigerator and good to go, later in the evening we notice the ice maker working fine and producing ice. Thank you parts select.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Johnnie from KANSAS CITY, MO
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
The Ground wires wasn't in same location on board
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
clyde from RIALTO, CA
Parts Used:
WR60X24484, WR60X10209
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leif from Jacksonville, FL
Parts Used:
WR17X11168
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Intake hose to ice maker broke
After shutting off the h2o, I unplugged the refrigerator. Using the nut driver, I removed the cardboard backing. Then I removed the fitting where the inlet line to the ice maker and pried the old tubing from the unit. I then undid the clasp about 1/2 way up the back and removed the section that went through the back to the ice maker.
I then reassembled everything and plugged in the refrigerator as well as turning on the water.
Keep in mind that because h2o and electricity are involved. MAKE SURE THERE ARE NO h2o LEAKS.