GSS22JETBBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- David from Sparks, NV
- Parts Used:
- WR17X11267
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Replace broken ice funnel dispenser cradle
Removed outer trim by pulling it carefully out of its clips. Then disengaged the electronic display card by grabing the bottom of the card to disengage the card from the upper clips. I leaned the card forward and disconnected the wire connectors. Removed the 4 screws to take off the frame that contains the funnel. Remove the broken funnel from clips. Note study how the spring is engaged. Note position of the rubber funnel how there is a gap for the water tube. Removed the rubber funnel and attached to new funnel dispenser. Start at one end of the rubber flap and work around engaging the rubber into tabs. Replace the Funnel dispenser back into frame. Make sure the longer wire of the spring sits flat on the plastic frame and that the right elbow of the spring raps around the edge of the funnel. Secured the frame assembly back into the Refig using 4 screws and attached out trim starting withe bottom tabs engaged first.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tim from West Palm Beach, FL
- Parts Used:
- WR50X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer coils icing up, fridge too warm
Had to remove inside panels to expose coils in freezer. Used hair dryer and towels to de-ice. Reading online learned about defrost heater (long thin glass tube with wire coil in it I could not see b/c up under the inside of the coils). Who would have guessed freezers have heaters in them!! And learned the defrost timer (inside the fridge) is just a continuous clock turning on and off the defrost heater. Anyways I used a screwdriver to turn the timer to defrost mode and by disconnecting the wires from each end of the heater and measuring the voltage, I found 70 volts there. Hmmm. I didn't know what was the right volt amount.
Reading online I also found out the defrost Thermostat is basically a temp actuated on/off switch for that heater, so that while the timer is sending *120* volts to the heater (which gets red hot by the way) the therm switches the heater off when the temp gets high in the freezer.
I eyeballed the therm ( it looks like a little can) and I saw that it was coming apart. The key at this moment is you can cut out and bypass the therm to see if the heater works. If it does you know the therm is the bad boy. But only do this as a momentary test or the heater will probably set your fridge on fire after a while!
Always remember to unplug the fridge when you are messing with the wires! And dry it up inside before putting your hands and tools in there!
So I ordered a therm using the model # of the fridge. Had to cut the old out and strip / wire nut the new one in.
Took too long b/c I was hung up on the heater being bad (after all it didn't heat up when I put the timer in defrost) and not knowing about the rights volts to the heater.
PartSelect helped out great! Thanks!
Reading online I also found out the defrost Thermostat is basically a temp actuated on/off switch for that heater, so that while the timer is sending *120* volts to the heater (which gets red hot by the way) the therm switches the heater off when the temp gets high in the freezer.
I eyeballed the therm ( it looks like a little can) and I saw that it was coming apart. The key at this moment is you can cut out and bypass the therm to see if the heater works. If it does you know the therm is the bad boy. But only do this as a momentary test or the heater will probably set your fridge on fire after a while!
Always remember to unplug the fridge when you are messing with the wires! And dry it up inside before putting your hands and tools in there!
So I ordered a therm using the model # of the fridge. Had to cut the old out and strip / wire nut the new one in.
Took too long b/c I was hung up on the heater being bad (after all it didn't heat up when I put the timer in defrost) and not knowing about the rights volts to the heater.
PartSelect helped out great! Thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Milton, FL
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Highlands Ranch, CO
- Parts Used:
- WR55X10942C
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Icemaker would not dispense cubes or crushed ice
Cause: Failed relays on main circuit board. Fix: Main circuit board replacement: Unplugged refrigerator. Removed 10 screws securing main circuit board metal cover (located on back of refrigerator) using a nutdriver. Disconnected 7 multi-pin electrical connectors from the circuit-board by firmly pulling each connector from the circuitboard sockets using a needlenose plyers. Depressed the small locking prong on each of the 4 plastic circuit board mounting pegs while pulling the board off the mounting pegs.
Pressed new board in place over mounting pegs. Re-plugged in all connectors (no confusion because each connector has unique pin counts). Replaced all mounting cover bolts, making sure to pin green ground wire to last bolt. Plugged in refrigerator. Done.
Note: I determined the main circuit board was bad by removing the auger motor assembly from the freezer and testing the auger motor harness power pins. AC voltage should jump when ice demand lever is pushed (while pressing the internal door light off switch). If no voltage jump, then auger motor relays on main circuit board have failed, indicating board replacement is needed.
Another check would be connecting an extension cord to the auger motor terminals and plugging it in. Motor should run. If it does, then motor is good and main circuit board is bad. If it doesn’t then auger motor is bad and needs replacement.
Pressed new board in place over mounting pegs. Re-plugged in all connectors (no confusion because each connector has unique pin counts). Replaced all mounting cover bolts, making sure to pin green ground wire to last bolt. Plugged in refrigerator. Done.
Note: I determined the main circuit board was bad by removing the auger motor assembly from the freezer and testing the auger motor harness power pins. AC voltage should jump when ice demand lever is pushed (while pressing the internal door light off switch). If no voltage jump, then auger motor relays on main circuit board have failed, indicating board replacement is needed.
Another check would be connecting an extension cord to the auger motor terminals and plugging it in. Motor should run. If it does, then motor is good and main circuit board is bad. If it doesn’t then auger motor is bad and needs replacement.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from waxahachie, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
No water or ice and a constant ticking sound from the control panel
Very easy repair to do. Read instruction sheet before starting! Unplug unit prior to removing panel cover.
Remove three hex head screws holding control panel cover in place and reveal the circuit board.
Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.
Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.
Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.
Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.
Voila!! No more ticking sounds and a plentiful supply of ice and water!!
Remove three hex head screws holding control panel cover in place and reveal the circuit board.
Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.
Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.
Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.
Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.
Voila!! No more ticking sounds and a plentiful supply of ice and water!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Suffolk, VA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CLIFFORD from SPRING CITY, PA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Freezer Cold, Refrigerator Section Warm
The problem with this model is usually a burned out heater assembly, when the freezer is still freezing, but the fresh food section is warm. To check, first disconnect power from refrigerator. Remove food and then shelves from freezer section. Remove the screws that hold the back freezer panel in place. Remove back panel and the coils will be exposed. If they are covered in ice the heater is most likely the problem. At the bottom of the coils below the heater assembly is a drain hole plug this hole with a rag. Place a large towel in bottom of freezer pan beneath the coils to catch the water. I do not recommend any method to melt the ice from the coils but a hair dryer, do not chip at the ice or you will most likely damage the coils. After you have defrosted the coils and removed all water from the unit, remove the two screws that hold the heater element in place, this element is directly below the coils. Look at the element, if it is burnt black, this is a tell tale sign it is bad. If that is the case it will need to be replaced. Remove the electrical wires located on te end of unit, the new unit will have instructions with it, reconnect the electrical wires per instructions, remount heater with the same mounting screws that held it in place. Be sure to remove rag from drain hole, replace back freezer panel with screws, replace shelves, and plug refrigerator back in. If your problem was a cold freezer section but a warm fresh food section this should fix your problem. In conclusion, this problem and the fix for it is indicative to these model's ge refrigerator's
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Mason, OH
- Parts Used:
- WR23X10783
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Water dispensor would not shut off
Actually this was a two part repair of which I purchased both parts. The micro switch Pt # PS296176 and also a double outlet water valve Pt # PS304374 from Parts Select as well.
The difficult part was accessing the area to get to the micro switch.
The trim had to be removed, then the cover.
Then one unplugs the board and removed the face plate which also contains the micro switch.
Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.
Then reverse the removal procedure.
Then on to the double outlet replacement.
Suggest watching the installation video for the replacement although it was really a straight forward repair.
Two things to remember.
1. Unplug the fridge
2. Shut off the water to the dispenser
Overall it was not bad at all.
This was my first attempt at refrigerator repair and it went well.
Good luck on yours.
John
The difficult part was accessing the area to get to the micro switch.
The trim had to be removed, then the cover.
Then one unplugs the board and removed the face plate which also contains the micro switch.
Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.
Then reverse the removal procedure.
Then on to the double outlet replacement.
Suggest watching the installation video for the replacement although it was really a straight forward repair.
Two things to remember.
1. Unplug the fridge
2. Shut off the water to the dispenser
Overall it was not bad at all.
This was my first attempt at refrigerator repair and it went well.
Good luck on yours.
John
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerry from Hamilton, NJ
- Parts Used:
- WR50X10068, WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Freezer stopped working
Came home in the morning and found that everything in the freezer was defrosted. The fridge and freezer were warm so I checked the web to see what the problem could be. After about 15 minutes I found what the two causes could be. Since the parts were so cheap, I decided to change both the defrost heater and thermastat. It's been about a week since I changed the parts and no problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Windham, NH
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers, Socket set
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leonard from Keller, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Main circuit board wouldn't allow the compressor to come on
Removed old circuit board and replaced with new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Au Sable Forks, NY
- Parts Used:
- WR51X10101, WR50X10068
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Freezer and Refrigerator both warm, frost buildup on freezer coil cover
De-iced cover and removed two phillips head screws and two 1/4 " nutdriver screws to expose coil, defrost heater and defrost thermostat. Deiced the coil and surrounding area with a heat gun. Removed two screws that hold the defrost heater in place, disconnected the wires to the original heater. The original assy. was a single quartz and the new one was a double quartz. This required rerouting the left wire along with the right one, but was no problem as the wire was plenty long enough. Re-installed the assy. with the two screws. I replaced the defrost termination thermostat, even though it tested good, because I have had experience in that it would be the next to go, and not to in-convenience the owner in unloading the fridge a second time. The only difficult part was fitting into the freezer compartment. As usual, order by 3p.m. and shipping is the same day and is a real joy to use Partselect.com
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- randall from danville, IL
- Parts Used:
- WR23X21074
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
my wife was putting a gallon of milk in to the refrigerator and hit the light switch with the container of milk ,breaking the light switch
i used a small slotted screw driver to gently pry the switch from the door casing ,once out i unpluged the switch and out the new switch from parts select it worked great.thank you for your prompt service.i will use you guys if i need any more parts.thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from The Villages, FL
- Parts Used:
- WR17X11168
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Tube feeding ice maker leaking.
Moved refrigerator out from wall. On the back of the refrigerator at the bottom there is a metal plate. Removed this plate with a socket wrench to expose where the end of the tube pluged in. The grommet securing the tube, white on my unit, had to be pushed up to release the old tube. I pushed the new tube into where the old one was and it self secured the tube. The other end of the grommet I pushed through the hole feeding the ice maker,first pushing out the broked part with a screwdriver,and securing that end with the attached sticky tape already attached to the grommet. I cleaned the area around the hole with alcohol before attaching the grommet.Replaced metal plate and done. No leaks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Aaron from Walnut Ridge, AR
- Parts Used:
- WR51X10101, WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Wouldn't defrost
Unplugged refrigerator, removed cover, defrosted with heat gun, replaced Defrost Thermostat, and replaced single element with double element Defrost Heater. All went very well with minimal difficulty, and instructions that accompanied parts along with the instructional video on your site, made the repair quite easy. The repair is going on the 4th week now, and no freeze up yet.
Was this instruction helpful to you?
Thank you for voting!