PFSF5NJWBBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Dan from COLUMBIA, SC
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from KNOXVILLE, TN
- Parts Used:
- WR60X30922
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice built up around evaporator fan blades and blades chipped and broke. Refrigerator was making loud vibrating noises.
Removed ice bucket, and unplugged ice maker. Removed light cover. Removed ice maker. Pulled fan blades straight up and removed. Pushed new blades on to motor shaft. Fairly easy .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gratnie from Newport News, VA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Water dispenser would not stop leaking on the unit.
First, turn off main water valve. Then, at the rear of refrigerator remove the rear panel exposing the water valve assembly. Cautiously, proceed by disconnecting the water hose and electrical connections. To complete the task, just worked in the reverse steps to exchange the faulty equipment.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Miamisburg, OH
- Parts Used:
- WR49X10283
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Refrigerator not cooling
1.Google troubleshooting for this issue. Determine the inverter card was bad. Installed new card and correct jumper harness per instructions. Total time to troubleshoot, remove & replace was about 30_45 min. Pretty simple
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sumlorq from Cleveland, OH
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light switch freezer door
put the gratefruit knife behind the old switch pooped it out pluged the new one in piece of cake 5min.even vacumed the dust off the coil
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from Warrenton, VA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set, Wrench set
Water was leaking from the cracked plastic valve
1 unplug fridge
2 turn off supply line for ice maker
2 remove lower back panel of fridge
3 disconnect in and out line from valve
4 remove valve (one screw.)
5 disconnect power line to valve.
reverse to reinstall. Very easy.
This valve is a cheap, poor design. This is the second one in 5 years. I replaced the first one because the line in the freezer would "drip" creating an ice dam so the ice maker wouldn't work. This time, the water dispenser on the front of the fridge has been dripping for months - finally the valve just dissolved and was spraying water all over the floor. It ran down into the basement. Keep a eye out if you have a GE fridge.
2 turn off supply line for ice maker
2 remove lower back panel of fridge
3 disconnect in and out line from valve
4 remove valve (one screw.)
5 disconnect power line to valve.
reverse to reinstall. Very easy.
This valve is a cheap, poor design. This is the second one in 5 years. I replaced the first one because the line in the freezer would "drip" creating an ice dam so the ice maker wouldn't work. This time, the water dispenser on the front of the fridge has been dripping for months - finally the valve just dissolved and was spraying water all over the floor. It ran down into the basement. Keep a eye out if you have a GE fridge.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from Ruther Glen, VA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Wrench set
My water hose broke, the valve is 1 use.
1. remove back shield of fridge.
2. unscrew old valve.
3. remove electrical connections.
4. remove white inserts on new valve.
5. cut feed hoses next to old valve.
6. place white inserts on hoses.
7 insert hoses into recepticals on new valve.
8 shut off water supply to fridge.
9. remove water suply line from old valve.
10. attach water supply line to new valve.
11. connect electrical connections.
12. bolt valve back on to fridge
13. turn on water supply to fridge
14. test both ice maker and water dispensor
15. replace back shield to fridge
2. unscrew old valve.
3. remove electrical connections.
4. remove white inserts on new valve.
5. cut feed hoses next to old valve.
6. place white inserts on hoses.
7 insert hoses into recepticals on new valve.
8 shut off water supply to fridge.
9. remove water suply line from old valve.
10. attach water supply line to new valve.
11. connect electrical connections.
12. bolt valve back on to fridge
13. turn on water supply to fridge
14. test both ice maker and water dispensor
15. replace back shield to fridge
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Loren from EL PASO, TX
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
40 year old refrigerator brittle light switch fell apart
with a jewelry screwdriver I pried the lock tab in and pulled switch down carefully, the hardest part was that the power wire connector was stuck on good but the pliers and the jewelry screwdriver was its match for a bout 5 minute for one connection a simple pull off prong connection. After the wire connected back to switch it popped back in SNAPP
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Glendale Heights, IL
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Light would stay on when door closed
Extremely easy repair, the hardest part was getting the old switch out. I used a pair of needle nose pliers to squeeze the tabs in and it came right out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from SUGAR LAND, TX
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light Switch Not Working - Needed New Switch
Remove the top cover above the door by lifting it slightly and pulling forward. I used a mirror to make sure that there was nothing in the way of accessing the switch from above. I used a blade screwdriver to press against the switch retainer on the topside, while GENTLY prying from below with another blade screwdriver to get the switch dislodged. Once the retainer was past the opening, I wiggled the switch downward and then rotated it to the left when the rounded top right edge of the switch was visible. This allowed the wiring to the connector to pass thru the hole. I pushed the wiring from the top and pulled from below to get the connector below the opening for the switch. I then unplugged the switch, plugged in the new switch and reversed the removal process feeding the connector thru first then rotating the switch to the right to get the rounded edge of the switch thru the opening, then pressed the switch up into the opening until it snapped into place. Total time less than 10 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from GREENSBORO, NC
- Parts Used:
- WR02X12008
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Fan was not centered in the middle of the back panel opening.
Bent the motor bracket down, then using a rat tail file, elongated the holes in the back panel of the refrigerator to secure the fan in the "centered" position. This was a problem that was with the refrig. since it was made. The parts involved were perfect. NO problem at all installing them.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from BURNEY, CA
- Parts Used:
- WR02X11331
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Socket set
Loud Squeal when fan was running
WE (WIFE) took out the old parts an replaced with new one ..Be careful to get the placement of the Grommet or they "POP" out on you. fast ship on the parts too.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Doug from Madison, WI
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set, Wrench (Adjustable)
Opend freezer door and found ice everywhere from dripping ice maker. Even with power unplugged water was still leaking through so I determined it must be the water valve at the back of the fridge that had failed.
Unplugged fridge. Shut off the water supply valve under sink. Removed lower access panel at back of the refrigerator (six screws). Removed single green screw holding water valve bracket and pulled assembly out to access wiring and hoses. It is a dual valve as one valve is for the water dispenser and one is for the ice maker. Disconnected the 2 electrical connectors (one for each valve). Unscrewed the compression fitting for the water inlet with 1/2 " wrench. Then the two water lines on the outlet which are quick disconnects. You must push the ring towards the valve and then the tubing can be pulled out by hand.
Reattach everything to the new valve and install and its ready to use.
Reattach everything to the new valve and install and its ready to use.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Matthew from Escondido, CA
- Parts Used:
- WR02X12008
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Fan making noise.
Remove ice maker and all of it's accessories in order to remove the panel covering the fan. Don't drop the screws!
Unscrew the lower fan bracket. You will see the lower red rubber grommet. Hold fan motor with one hand and push the fan off the shaft and into the compartment above. Then remove the round retainer thing below it by holding it and pulling down on the motor assembly. Install new grommet on upper part. and put it all together.
REMEMBER where the fan is on the shaft. It has about one inch of shaft placement. I put mine so that most of it was above the hole that the fan goes into and about 20 percent showing below the sheet metal.
Also check to see if your fan is damaged. Mine was not.
This refrigerator has been awesome! I have had many issues but have been able to fix all of them for the last 15 years!
Unscrew the lower fan bracket. You will see the lower red rubber grommet. Hold fan motor with one hand and push the fan off the shaft and into the compartment above. Then remove the round retainer thing below it by holding it and pulling down on the motor assembly. Install new grommet on upper part. and put it all together.
REMEMBER where the fan is on the shaft. It has about one inch of shaft placement. I put mine so that most of it was above the hole that the fan goes into and about 20 percent showing below the sheet metal.
Also check to see if your fan is damaged. Mine was not.
This refrigerator has been awesome! I have had many issues but have been able to fix all of them for the last 15 years!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carolyn from Santa Ana, CA
- Parts Used:
- WR02X12149, WR02X12008
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Loud Sound In Freezer
I followed the video for my model refrigerator on parts select. My hint: when returning the back panel of the freezer, it's slightly adjustable left and right to avoid grazing the fan.
Was this instruction helpful to you?
Thank you for voting!