Models > GSK25LHSACCC > Instructions

GSK25LHSACCC General Electric Refrigerator - Instructions

Jump to:

All Instructions for the GSK25LHSACCC
121 - 135 of 289
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Allan from Ann Arbor, MI
Parts Used:
WR11X10008
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
I broke a door closer while moving the appliance.
When the Part Select website predicted delivery in a couple of days, I doubted - I was prepared to wait a week or so. Incredibly, the part arrived the day after I ordered it. Replacing it was no problem, because the exploded view of the hinge area showed a clear and easy way to remove the broken part and slip in the new. It was just 2 inches of plastic, but if I hadn't found it so easily, the whole appliance would have been useless.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Sea Cliff, NY
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The freezer temperature was increasing.
i took out back frame and cleared off the ice on the metal condenser. I cut wires from old thermostat and removed it. Stripped new wires and attached to the wires in the frig. We taped it with electrical tape and put it back and closed it up. it works beautifully! We watched a video on youtube and that helped a great deal!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jerome from Knoxville, TN
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Frost buildup causing freezer to warm up
Unplug the refrigerator. Pull all shelves out of the freezer. Remove light bulb shield and light bulb. Remove the two hex head screws on either side of the light bulb. Wiggle out the back wall. It is a tight sqeeze, but can be done. Locate the sensor on the top of the coils. It is held on by a simple clip. Wiggle the sensor and twist a little to take it off. Take wire cutters and cut the two wires into the sensor near the sensor to allow lots of room to splice in the new sensor. Strip about a quarter inch of wires left in the freezer. Use some sort of wire connectors, like twist caps, which will allow you to connect the two wires to the new sensor. Make sure to match the colors. I used shrink tube and line connectors. Once you have the new wires spliced together and protected with either shrink tube or electrical tape, tuck the excess wire out of the way and attach the new sensor. This is easily done by slight pressure on the sensor with the tube in between the clip and sensor. Make sure the wires are tuck out of the way and reassemble the freezer panel, light bulb, and shelves in the reverse order.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from Monroe, WA
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Refrigerator hot, freezer normal
Refrigerator was showing actual temperature of 80 deg, freezer was about 3 deg high. (house temp was 65 at the time) Defrost heater seemed like the only component able to heat that much, so the defrost thermostat seemed like the likely culprit. I followed the installation directions in the video, and the fridge has been fine ever since.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Walt from Freeport, FL
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
The freezer would freez up and stopp cooloing the entire unit
I took the ice maker out then the panels that closes in the evaporator coil. Disconnected the defrost censer and tested it with an ice bath. The censer did not close the circuit. So it's bad. I got the parts .(Very fast I might add. The PartSelect team did a great job of getting it to me). I the stripped the wires and spliced the like colors back together and tested the censer again with an ice bath. It closed this time. I started the frig and have not heard anything from the client. In this case "No news is good news". Thanks PartSelect
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Montrose, CO
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
Fridge kept getting warmer and frost started building up in Freezer
I ordered the part but my husband had to work out of town for a week. The fridge kept getting warmer, so when the part came I just watched the video on the internet, (bit the bullet) and did the repair just as I saw it done on the video. It was simple and exactly the same as the video. It took a little longer for me because there was a lot of ice built up on the coils, so I used my hair dryer to melt the ice. My refridgerator is working great now.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randall from Stone Mountain, GA
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Freezer and Fridge barley cold
I took off the back panel in the freezer. Located the wires going to the old thermostat, cut them with wire cutters. I then spliced the matching wires together and attached the part to the coil tube (There is a little clip on the part, be sure to do this because I forgot and had to go back and do this again!!!).
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Elkton, KY
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
freezer running warm. freezes up.
I followed the instructional video. It was right on the money for accuracy in terms of part location and method of replacement.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
bryan from charlotte, NC
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Freezer warming up
All the rest of everyone's post are all what I did. The only other thing I recommend is to put the back panel over the evaporator coils when your done. I replaced defrost thermostat, and heater. Once I initially completed it it kept icing over more than usual. You have to put the back panel back on so airflow goes over the coils.
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Salvatore from Monroe Township, NJ
Parts Used:
WR50X10068
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
Freezer staying in defrost mode for too long.
My Ge top freezer fefrigerator was going into defrost mode and the heater was staying on for too long causing the food to thaw and eventually refreeze. Originally thought it was the mother board but after researching and do some troubleshooting of my own I realized the defrost terminating thermostat was bad. $8 part from Parts Select. Accessed the evaporator by removing back wall plate. Located thermostat and cut two lead wires to it. Spliced in new thermostat and reattached to eveaporator. Refrigerator seems to be good as new. There is an installation video on the web page that shows you step by step proceedure.
1 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Boston, KY
Parts Used:
WR17X11168
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Broke ice maker supply tube while moving fridge.
Used nut driver to remove two screws at top of tube, and the three screws holding composite cover on back of fridge. Pulled out the upper portion of tube, pulled up on fitting and removed lower portion of tube. Put upper spout portion of new supply tube into position, replaced two screws, pushed lower portion of tube into locking fitting on supply valve solenoid. Replaced composite cover with three screws, and was done. Entire job took less than 5 minutes. It took longer for me to find my nut driver set, than it took to do the repair. I ordered the part online, and it was delivered to my door in a lightning fast 36 hours. Hopefully I won't ever need any more appliance parts, but with your easy to navigate website, fast shipping, and fair prices, you have won me over as a customer. I will refer you to friends because of your high speed, low drag, zero defects, excellent service. Thank you very much. Rich.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wendell from Baton Rouge, LA
Parts Used:
WR60X24484, WR02X12149
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Rat chewed up fan blades in refrigerator at our camp.
We just pried off the fan blades and pushed on the new part. Could not have been easier. The rat has been permanently dipatched and, hopefully, that is that.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from Titusville, FL
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Dropped a glass bowl hitting and breaking off the light switch.
Ordered the part and within three working days the part was delivered. It took two minutes to pry off the broken part and one minute to snap in the new one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roman from Fort Worth, TX
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light switch was broken
replaced with new one
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jesse from Kingman, AZ
Parts Used:
WR50X10068
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Frost build up on coils
Removed shelves and light bulb. Undid the two screws on the back panel with nut driver. Snipped the two wire leads to the defrost thermostat. ( orange and pink wires) Carefully removed the defrost thermostat from the coil. Stripped both ends of the wire leads about a half inch and onnected with two wire nuts. Then wrapped with electrical tape to seal from moisture. Carefully attached defrost thermostat to coil. Screwed the back panel back on. Reinstalled light bulb and shelves. And plugged refrigerator back in. Works like a charm. Saved close to 100.00 dollars doing repair myself.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GSK25LHSACCC