- Customer:
- Gary from Pickens, MS
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Ice maker was over filling and freezing the cubes together.
I turned water off at valve and unplugged refrigerator. I removed screws to remove cardboard cover at bottom. I removed screw holding duel inlet water valve bracket and pulled out valve. Then it's just a matter of exchanging electrical connections and water lines. The electrical connections unplug and plug in-red to red and blue to blue. The water lines are two different sizes so they can't be mixed up. Then reattach bracket and cardboard cover. Turn water back on and plug back in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ROBERT from OCALA, FL
- Parts Used:
- WR49X10283
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench set
Not Cooling
-Pulled refrigerator out to access back.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from FARMINGVILLE, NY
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refrigerator not cold
removed freezer door / shelf /ice maker pulled back panel off and removed fan
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Tampa, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water not dispensing
Moved refrigerator forward, this allowed me to work on the back panel. Unplugged the refrigerator power cord. Released all 6 screws, removed panel then release an additional screw that was holding the water valve and the two (red & blue) connectors. Then installed the new part in reverse steps. Plug the unit and job well done. I had purchase the water filter already after several minutes push for water from the dispensing front part of the refrigerator and good to go, later in the evening we notice the ice maker working fine and producing ice. Thank you parts select.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Federal Way, AL
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Difficulty in removing the old switch
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from Crown Point, IN
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator light wouldn't come on.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Longwood, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
No water dispensed from door tap, icemaker OK
The problem was both the valve and a frozen slug of water in the supply line located inside the door. After replacing the valve, I turned the freezer to a setting of 1 and in about 30 hours, water flowed out the tap.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Helotes, TX
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
Ice build up behind ice maker ,water chute frozen up
Unplugged ref.,turnned water off at wall and drained, removed back cover on lower part of ref. then removed screw holding water valve,unplugged both wires from unit,pulled the 3 water lines off,1 I had to cut, would not release,got new water valve,push 3 water lines in place,attached the 2 wires in place and screwed unit back on ref.and replaced back cover on ref. Then I got a hair dryer and thawed all ice that had built up behind and under ice maker in freezer,cleaned that mess up,turned water back on plugged in ref. All good ,repaired problem,old water valve was bad.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from HAYWARD, CA
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Water dispenser is not working........water not coming out!
Show installation!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- charles from SCOTTSDALE, AZ
- Parts Used:
- WR55X10025
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from RINGGOLD, GA
- Parts Used:
- WR49X10283
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
compressor won't kick on
Pulled ice box away from wall. Took lower cardboard cover off. Shut water line off. Got my volt meter and checked the current going from the wall to the plug in at the inverter (input side), and I had the required 115 volts. Then I unplugged the connection going to the compressor (not the plug at the compressor which you cannot see until you unbolt the inverter) but the output connection side that goes to compressor. I checked the voltage and had about 13 volts not the required 115 volts. Therefore, I came to the conclusion that the inverter was bad. I ordered one from Partselect and they shipped it right away. I installed it and the ice box is back up to running order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Theodore from Carteret, NJ
- Parts Used:
- WR57X33326
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Water Leak behind Refrigerator
Shut water behind the refrigerator, unplugged the unit. Unscrewed the back tin panel and simply unscrewed the brace scew for the Double Outlet Water Valve. Disconnected the hoss - inspected the hosed for wear. Next detached the hoses and power source to the unit... reconnected both hoses & power source, plug the refrigator back in and inspected for any water leaks. Simple!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Katherine from Converse, TX
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Was very helpful to have a video giving you instructions
Of course being a women to say I repair my refrigirator is very self gratifying specially when share with other womens like me divorce,having to do on their own, great site, very simple explain on the video with words I could understand, no surprices right to the penny. I save a lot of money, thank you so much, i recomend the site to anybody.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- randall from coopersville, MI
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
refriderator not cooling consistetly
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
Was this instruction helpful to you?
Thank you for voting!