GNE21FMKVFES General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Troy from Dacula, GA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Food section of fridge always warm
Located temperature sensor on condenser in the freezer section( as per instructional video ). Cut off bad sensor with wire cutter then soldered on the new sensor and sealed with electrical shrink wrap.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ajaykumar from Plainsboro, NJ
- Parts Used:
- WR60X10209
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The refrigerator was making load and unusual noises.
I identified the noise was coming from the coils / and the fan. Cleaning the fan helped reduce the noise a bit but it still kept recurring. I ordered the part, which was really easy using the diagram on the website. The instructions and the video were really helpful and was able to remove the old motor and replace it with the new one with relative ease. While there I cleaned the fan blade and vacuumed the surrounding area. This whole repair went quite smoothly and has given me the confidence to take on other repairs before calling out the repairman.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Colby from Blanding, UT
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Starter/overload assembly and run capacitor were bad
Removed rer cover, unplugged starter assembly from side of compressor and replaced unit with a new one. Plugged fridge in and it works good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gordon from Sugar Grove, IL
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Pliers, Screw drivers
defrost problem (refrigerator/freezer not cooling)
After replacing the Defrost Thermostat, Defrost Heater Assembly, and the Main Board, I concluded that the problem must be the Defrost Thermistor, which I replaced in less than 10 minutes and it fixed the problem! I cut the wires on the old thermistor and connected the new one after stripping the wires and taped the new connections with electrical wire. Fast and easy repair (the last part anyway ;).
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from Decatur, GA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Refrigerator Fresh Food condenser iced-up. Frozen side OK
Had to remove all the covers and fans to expose the condenser, which was difficult as the parts were frozen to it. The styrofoam covering the condenser made it almost impossible to defrost it. Therefore, I ripped the styrofoam off to expose the condenser. Was not really difficult to fix the styrofoam cover using metal tape. Replaced temperature sensor in aluminum block, and used butyl sealant to secure. Had to also re-install parts of ice-ball kit that were not well covered. Lots of parts to keep track of, but anyone could do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edwin from Quincy, CA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Refrigerator Running Warm, evaporator is not defrosting.
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
Was this instruction helpful to you?
Thank you for voting!