Customer:
Colby from Blanding, UT
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Starter/overload assembly and run capacitor were bad
Removed rer cover, unplugged starter assembly from side of compressor and replaced unit with a new one. Plugged fridge in and it works good.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura from Brentwood, MD
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
freezer and refrigerator wasn't cold
Replaced all the sensors in both the feezer and refrigerator.Even though it colder now it still is not cold enough.Freezer won't freeze items but is cold and refrigerator still not real cold
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gordon from Sugar Grove, IL
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Pliers, Screw drivers
defrost problem (refrigerator/freezer not cooling)
After replacing the Defrost Thermostat, Defrost Heater Assembly, and the Main Board, I concluded that the problem must be the Defrost Thermistor, which I replaced in less than 10 minutes and it fixed the problem! I cut the wires on the old thermistor and connected the new one after stripping the wires and taped the new connections with electrical wire. Fast and easy repair (the last part anyway ;).
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chuck from TARRYTOWN, NY
Parts Used:
WR55X24064, WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary from Farmingdale, NY
Parts Used:
WR55X24064
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Both the fridge aqnd freezer would not get cold.
Easy. Followed the video instrucations. the part was right there next to the compressor.
Was this instruction helpful to you?
Thank you for voting!