Fridge making LOUD humming sound.
Started removing screws until I got to the fan (it's easy). Then just took out the old fan and put the new one back in the same way. The only challenging part was putting the clamp back on the fan, but I finally got it. The fridge is finally quiet and we can sleep again! PartSelect made it really easy and they were incredibly fast. Thanks!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter M. from Lincoln Park, NJ
- Parts Used:
- WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paypal_shipping_address from Ripon, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Herbert from POCONO LAKE, PA
- Parts Used:
- WR60X10168, WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
the condenser fan motor was intermittently verynoisy. obvious sign of a (possibly imminent) failure
1 unplug the appliance
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jacky from Richland, GA
- Parts Used:
- WR60X10207, WR60X10168
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Old fan motor was knocking and not running well
Watched your repair video online. appeared very simple and straight forward. Order the parts in question. They were shipped quickly. Once parts in hand watched video again and then installed new motor and blade in less than ten minutes. Plug power back in and and new part works perfectly. Thanks for helping make it an easy process. J. Smith
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from EAST JORDAN, MI
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Light went out in refrigerator
Pop out switch, pull wires, attach wires to new switch and pop back in. Easy smeasy!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from NEW YORK, NY
- Parts Used:
- WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
noisy refrigerator
I followed your video and completely dismantled the refrigerator evaporator motor, fan, brackets, and grommet, I completely cleaned the refrigerator including the cooling coils. I then ordered the evaporator motor ,fan, grommets, lid bumper, and brackets. The order would take a week to arrive. In the meantime I cleaned and reassembled all the old parts, waiting for the new ones to come. Guess what! The refrigerator was quiet as a mouse. I really did not need the new parts, but I kept them anyway just for good luck. Not bad for a refrigerator that's twenty four years old.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PARKVILLE, MO
- Parts Used:
- WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Matthew from Escondido, CA
- Parts Used:
- WR02X12008
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Fan making noise.
Remove ice maker and all of it's accessories in order to remove the panel covering the fan. Don't drop the screws!
Unscrew the lower fan bracket. You will see the lower red rubber grommet. Hold fan motor with one hand and push the fan off the shaft and into the compartment above. Then remove the round retainer thing below it by holding it and pulling down on the motor assembly. Install new grommet on upper part. and put it all together.
REMEMBER where the fan is on the shaft. It has about one inch of shaft placement. I put mine so that most of it was above the hole that the fan goes into and about 20 percent showing below the sheet metal.
Also check to see if your fan is damaged. Mine was not.
This refrigerator has been awesome! I have had many issues but have been able to fix all of them for the last 15 years!
Unscrew the lower fan bracket. You will see the lower red rubber grommet. Hold fan motor with one hand and push the fan off the shaft and into the compartment above. Then remove the round retainer thing below it by holding it and pulling down on the motor assembly. Install new grommet on upper part. and put it all together.
REMEMBER where the fan is on the shaft. It has about one inch of shaft placement. I put mine so that most of it was above the hole that the fan goes into and about 20 percent showing below the sheet metal.
Also check to see if your fan is damaged. Mine was not.
This refrigerator has been awesome! I have had many issues but have been able to fix all of them for the last 15 years!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- THOMAS from MEBANE, NC
- Parts Used:
- WR60X10168
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Noisy Fan Motor
Simple. Rolled the refrigerator out , unplugged the 120 volts AC outlet.(1) Unplugged the wiring from the cabinet to the fan (white (three pin connector)). (2) Removed the two 5/16 inch screws holding the rear motor bracket . (3) Removed the fan blade from the motor shaft by applying slight pressure, pulling if off the old motor shaft. (4) removed the rubber isolator from the frame and from the rear of the old motor. (5) placed the rubber isolators back on the motor and frame. (6) Pushed the new motor back into the frame and re-installed the fan assembly. (7) remounted the fan with the rear support and the two 5/16 inch screws. Reconnected the three wire connector. Just checked the fan blade assembly to make sure they were not hitting the fan shroud. Fan blades should sit just partially inside the shroud to make sure it produces maximum airflow.
(8) Reconnected the 120 volt AC and waited for the compressor to cycle back on... Nice quite fan... Thanks
(8) Reconnected the 120 volt AC and waited for the compressor to cycle back on... Nice quite fan... Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronnie from BATON ROUGE, LA
- Parts Used:
- WR82X10111
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
had no access cover on back
screwed the cover on just like the original
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Catherine from SEATTLE, WA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roscoe G from ROCHESTER, NY
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sumlorq from Cleveland, OH
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light switch freezer door
put the gratefruit knife behind the old switch pooped it out pluged the new one in piece of cake 5min.even vacumed the dust off the coil
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from CHAMBERSBURG, PA
- Parts Used:
- WR60X31522, WR02X12008
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Fan became noisy
First unplug freezer and empty contents, then remove the screws from the air deflector, carefully remove styrafoam air deflector block then remove back panel for easy access. Fan will be easy to switch out from there. I highly recommend the You Tube video which is where I got my basic instructions.
Was this instruction helpful to you?