- Customer:
- Deanna from MANDAN, ND
- Parts Used:
- WR01X10450
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Fridge handle missing set screw.
Opened the package. Set screw fell on floor. Luckily cat found it right away. Fight the cat for the screw. Dug through my tools and the first Allen wrench I picked up fit. "What the hell? That never happens so obviously the screw won't fit," I think to myself. Put the screw in the hole and give it a few turns until my fat finger can't hold it. It's a miracle and the thing fits! Fight the close quarters with the Allen wrench to tighten it. Works like a charm!! Now I don't scare myself when I open the door thinking I'm going to rip the handle right off. Now I have easy access to my ice cream. The parts finder tool on the website was really easy and I found what I was looking for.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jerry from Mindoro, WI
- Parts Used:
- WE01X20419
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The plastic door handle on the dryer broke and came off.
I received the replacement part I ordered from PartSelect.com within 3 days of placing the order. I opened the plastic bag it came in. I snapped the part into the holes left vacant by aforementioned abscence of broken part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brad from Laguna Niguel, CA
- Parts Used:
- WE03X29897
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The belt borke after 10 years of use.
1st - removed the two screws inside the front door panel. They are somewhat hidden up underneath so you may have to look for them. 2nd - I removed the top of the dryer cabinet by lifting it out of the clips holding it in place. 3rd - removed the two screws (one on each side) in the o=uppper corner of where the side panels connect the front panel. These are about 3/4" phillips head screws. Then the front panel could be moved to one side of the dry. 4th - remove the drum by lifting it up and out the open top area. 5th - add the new belt to the dryer tub (rib side towards the drum) and replace dryer tub to its original position. 6th - reaching in underneath the tub you need to pull the ideler pulley toward the center of the cabinet while laying the belt on the "outer side" of the ideler pulley and at the same time fitting the belt over the small pulley located on the motor. Once that is done, you reassemble in reverse order and should be good to go.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sam from Durham, PA
- Parts Used:
- WE12X81
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Dryer became very noisy
--Removed bottom rear panel (right under where 220 line comes in) which exposed belt and idler pulley.
--Relieved tension on belt by moving idler arm and moved belt off idler puller (just to the side).
--Removed e-clip.
--Removed old pulley and washers.
--Installed new thick plastic washer first, then pulley, then e-clip.
--Relieve tension and place belt back on new pulley.
--Replace back panel.
-Fini!
--Relieved tension on belt by moving idler arm and moved belt off idler puller (just to the side).
--Removed e-clip.
--Removed old pulley and washers.
--Installed new thick plastic washer first, then pulley, then e-clip.
--Relieve tension and place belt back on new pulley.
--Replace back panel.
-Fini!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mike from Aguilar, CO
- Parts Used:
- WR49X10283
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
my refrgerator stopped cooling and freezing
Take the cardboard grill off the bottom of the back it is held on with 5-6 hex head screws. Located the voltage inverter on the tank. It's on the bottom left of the refrigerator. Removed the screw that holds it in place.Remove the jumper wires at the quick connect. Rotate the voltage inverter and removed it. Check the voltage at the plug in going to the voltage Inverter. It should be 115-125 volts. Plug in the voltage inverter to the Quick connect away from the tank check the voltage on the side that would be connected to the tank. If both sides don't read at least 115 volts the inverter is bad. Order a new on and reinstall in the reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Terry from Simi Valley, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marty from BOX SPRINGS, GA
- Parts Used:
- WE4M181
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Would not heat up
Took the few screws out replaced the part then put it back together.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from CLAYTON, NJ
- Parts Used:
- WB06X10610
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Tripping circuit breaker, broken micro switch locking pin
1. Unplug unit
2. Open door, remove two screws above the top trim piece, slide and remove trim.
3. Remove screw behind control board and top left corner, then release from position.
3b. Unplug all wire terminations and set control panel aside.
4. Remove two screws securing latch board, lift and rotate board out of position, remove three micro switches, xfer monitor switch actuator from lower pin in old board and insert in new. Install new door switches and reverse procedure to complete repair.
Note 1. Take care to located new latch board so holding tabs line up, pass through frame, and openings for door tangs line up with openings in frame before securing with screws.
Note 2. A long magnetic screwdriver is helpful.
2. Open door, remove two screws above the top trim piece, slide and remove trim.
3. Remove screw behind control board and top left corner, then release from position.
3b. Unplug all wire terminations and set control panel aside.
4. Remove two screws securing latch board, lift and rotate board out of position, remove three micro switches, xfer monitor switch actuator from lower pin in old board and insert in new. Install new door switches and reverse procedure to complete repair.
Note 1. Take care to located new latch board so holding tabs line up, pass through frame, and openings for door tangs line up with openings in frame before securing with screws.
Note 2. A long magnetic screwdriver is helpful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Jupiter, FL
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- bill from clarendon hills, IL
- Parts Used:
- WE18X25100
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
lint filter was broken
took out broken filter and replaced with new lint
filter.
filter.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Hector from SAN PEDRO, CA
- Parts Used:
- WE4M416, WD21X10261
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
First, no heat; then, no run
Washer/dryer belongs to a friend. Originally, the problem was that the dryer wouldn’t heat, so I opened it up, and removed the drum thinking it might be the heating element. It wasn’t, and the ohm reading confirmed this. It turned out to be a burnt wire connector to the element ( unknown to me, and found out later, was that the start switch had remained continuously in the down position because the switch was pressed too far down and thus remained locked “on” in place under the surrounding cabinet frame. This, in my opinion, caused for a continual call for heat and thus burnt the wire.)
I replaced the burnt wire/connector and reassembled. Now the dryer would heat, but would only run if the start button was continually depressed. Let go of the button, and the dryer stopped.
Repair pros suggested a new start switch. I bought a new start switch along with a new interlock switch (it basically shuts off dryer if belt breaks because lack of a belt releases pressure on the pulley that keeps switch depressed.) Apparently they can go bad, too.
It turns out neither of these switches were bad. Instead, upon further inspection, after the first installation of the drum belt, the L-shaped bracket which holds the pulley for belt tension became dislocated from its correct position and was not allowing for the depression of the interlock switch, causing the dryer to “read” broken belt, and thus, not run.
I loosened the motor bracket to allow placing the bracket in the correct position. Reassembled and all was good.
PSA - almost every sheet metal edge is razor sharp.
In the process of returning parts. Now in the process of returning parts.
I replaced the burnt wire/connector and reassembled. Now the dryer would heat, but would only run if the start button was continually depressed. Let go of the button, and the dryer stopped.
Repair pros suggested a new start switch. I bought a new start switch along with a new interlock switch (it basically shuts off dryer if belt breaks because lack of a belt releases pressure on the pulley that keeps switch depressed.) Apparently they can go bad, too.
It turns out neither of these switches were bad. Instead, upon further inspection, after the first installation of the drum belt, the L-shaped bracket which holds the pulley for belt tension became dislocated from its correct position and was not allowing for the depression of the interlock switch, causing the dryer to “read” broken belt, and thus, not run.
I loosened the motor bracket to allow placing the bracket in the correct position. Reassembled and all was good.
PSA - almost every sheet metal edge is razor sharp.
In the process of returning parts. Now in the process of returning parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- blanche from Delray Beach, FL
- Parts Used:
- WE1M1011
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
latch on door broken, dryer could not function
I just pressed the latch with my thumb, the latch went in, and voila....job done. Thank you
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cindy from St. Charles, MO
- Parts Used:
- WE03X37317, WE1M825, WE03X37318, WE14X25080
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Terrible squeak and slow drying
Open it up. Try to fix with duct tape. Test. Fail. Order parts.
Put slides on, open it up, put parts on door, align drum, close it up.
Start, smile and BRAG!!!!
Works faster, fluffer clothes and I'm a happy Mom because now I can run whenever and there is less wrinkles.
Put slides on, open it up, put parts on door, align drum, close it up.
Start, smile and BRAG!!!!
Works faster, fluffer clothes and I'm a happy Mom because now I can run whenever and there is less wrinkles.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from Warwick, NY
- Parts Used:
- WE01X20419
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
handle broken on dryer
Removed the broken handle from the dryer and popped on the new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patrick from QUINTON, VA
- Parts Used:
- WD21X10261
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Dishwasher would not turn on.
There are 2 switches that should be pressed in when you move the handle to lock door, the switches usually go bad with time. Just take the six screws off on the inside of door, then remove screw on the underneath part of handle. The switches are located on the top part under a piece of 1 inch metal plate held in by a screw, remove that and you'll see the 2 switches, test the button on each one to see if it goes in and out, you'll hear the click to. Just unplug bottom first then the top if you need to replace the top one. Thats it.
Was this instruction helpful to you?
Thank you for voting!