Customer:
Frank from VERO BEACH, FL
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
The Refridgerator and Freezer were not cooling.
Installing the part repaired the fridge and freezer immediately.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from ROSEMOUNT, MN
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
elissa from ASHBY, MA
Parts Used:
RPWFE
Difficulty Level:
Very Easy
Total Repair Time:
More than 2 hours
Replaced thermistor 5.2 ohms of resistance
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MICHAEL from MONMOUTH BEACH, NJ
Parts Used:
WR30X28682
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
Ice maker failure
Ordered a replacement ice maker. Simple to remove old unit one screw and one screw to remove wire cover to unplug. Replacement unit looked a little different as the left side of the new unit had various ridges which did not allow a proper fit into ice making box. After examining old unit and new I swapped the old left cover with new left cover and unit fit perfectly and it is working correctly. I suggest adding a quick note about the upgraded part as it may not fit properly and the side cover may have to swapped out.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Les from Visalia, CA
Parts Used:
WR30X28682
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Lower Ice Maker making loud knocking noise
Removed all containers from the freezer,
Removed lower freezer door, 3 bolts on each side.
Removed one front screw on the ice maker, unplugged two connectors on slide off unit
Removed covers on the old ice maker and installed on the new one
Installed the new ice maker in reverse of the removal process

Inspected the old ice maker and found the motor drive gear had missing teeth; I believe that the heater on the ice maker was failing causing a strain on the drive gears
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from LAKE PLACID, NY
Parts Used:
WR71X11063
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Replace butter compartment on GE Profile
It just snapped in. Fit perfectly. Excellent service.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from Salisbury, NC
Parts Used:
WR71X11045
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
I dropped The top left bin and it cracked
Popped it up and popped new one on
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from COLUMBIA, SC
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from JUNEAU, WI
Parts Used:
WR55X44126
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Door water and ice dispenser not working
It was very simple. Removed 4 screws on top of door where panel is located. Unplug 3 three connectors and removed board. reinstalled new one in reverse mode. On the down side this did not solve the problem. I am still working on it.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from JUNEAU, WI
Parts Used:
WR55X44126
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Door water and ice dispenser not working.
Replaced door circuit board. Vert simple to do. Problem was not solved! Replaced the main board with advice of ge tech. problem not solved. Currently waiting for the Tech to reappear. Not a happy person
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kent from Bartlesville, OK
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
QUOC-LOC from LYNN HAVEN, FL
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sara from White Plains, NY
Parts Used:
RPWFE
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Water filter needed changing.
Snap filter into place while holding the filter slightly away from the refrig. When filter snaps into place, push it towards refrig into place.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Vernon from Harmony, NC
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
coil frosting up and refridgerator section was not cooling
took out shelves and removed the back plate my removing 2 screws with a nutdriver.removed the old defrost timer and defrost heater which was really easy.then installed the new ones.the video i watched on the website was really helpfull.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edwin from Quincy, CA
Parts Used:
WR55X10025
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
Refrigerator Running Warm, evaporator is not defrosting.
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
Was this instruction helpful to you?