GDE21ESKNRSS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Frank from VERO BEACH, FL
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The Refridgerator and Freezer were not cooling.
Installing the part repaired the fridge and freezer immediately.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from DURYEA, PA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from ROSEMOUNT, MN
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from WAUWATOSA, WI
- Parts Used:
- WR01X39781
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
For the second time the handle clips broke on the freezer. This time it also broke part of the mating bracket in the handle. Poor design. Last time I could get away with just the clips on the freezer door.
The handle was already broken. Wish I would have checked the mating clip surface of the handle. But, after getting all set up saw this problem, and ordered a handle. Taking off and installing is simple. Tap the freezer handle end to the left using a soft mallet on the right end. I suspect a hammer would work, but without protecting the handle could bend it or at least scratch the paint. I suppose a folded rag and a hammer may work. Anyway, once off, replacing the clips on the door is a Phillips head screwdriver to unscrew and replace the door clips. Then, carefully tapped the handle from the left end to slide the mating piece in the handle back on and tap tightly. There were many YouTubes on the thing since it seems to me to be a very poor design. But maybe we are too hard on the handle???
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from KNOXVILLE, TN
- Parts Used:
- WR60X30922
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice built up around evaporator fan blades and blades chipped and broke. Refrigerator was making loud vibrating noises.
Removed ice bucket, and unplugged ice maker. Removed light cover. Removed ice maker. Pulled fan blades straight up and removed. Pushed new blades on to motor shaft. Fairly easy .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from COLUMBIA, SC
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from Bartlesville, OK
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rose from Dorr, MI
- Parts Used:
- WR60X30922
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Broke the fan blade when replacing the Evaporator motor
Took cover off, pushed blade on, and replaced cover
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Naomi from SPRING VALLEY, WI
- Parts Used:
- WR01X39781
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Part broken accidentally.R
Repair was made simply and quickly by removing broken parts and replacing with new. No problems
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from WEST HARTFORD, CT
- Parts Used:
- WR50X10069
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Temperature
I couldn’t repair the problem because the part that came did not have the clips to crimp on the end that go into the modular connection,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- QUOC-LOC from LYNN HAVEN, FL
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura from Brentwood, MD
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench set
freezer and refrigerator wasn't cold
Replaced all the sensors in both the feezer and refrigerator.Even though it colder now it still is not cold enough.Freezer won't freeze items but is cold and refrigerator still not real cold
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brandon from Bruceton Mills, WV
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Defroster stopped working and iced up evaporator coil
I have a GE Profile French door refrig. It's only about 4 yrs old and the defroster stopped working. I read the other repair stories and was able to narrow it down to either the temp sensor, defrost timer, or main board. The refrig section was up to about 47 degrees and freezer was around 25. I could tell it was trying to cool but couldn't. So I tried the temp sensor first. I cut and spliced the new sensor on the outlet of the Evap. Coil and it took about 15 mins. Turned refrig back on and waited. The coil started to ice over after about 5 hrs I left the back panel off so I could see if and when then heater kicked on. After about 8 hrs I looked in and saw a faint glow and water trickling down and running out the drain. Turned out the sensor was bad and wasn't telling the main board it needed to defrost. I would try the sensor if you are having the same issues before spending a lot of money on the main board, defrost heater and or timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from Warrenton, VA
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Refridgerator not cooling, freezer frosting over
First, I had to remove the freezer drawer front. This is 8 large phillips head screws. then remove the plastic cover over the drawer slides. to do this, remove the white center screw from the slide near where it attaches to the drawer front. then the plastic cover will slide off pushing to the rear of the slide. take off the slides from the freezer walls by removing the phillips screws and pulling them towards you. They have tabs/slots in the rear. remove the center tray support and support bars, too. the icemaker has to come out, that is just 2 phillips screws but you also have to disconnect the electrical connector. just squeeze the locking wings and rock/pull. a screw in the top center of the back panel comes out. Lift and pull the back panel out. The evaporator coil appears. The thermocouple is attached to the coil in the upper right. Cut that one's wires and take it out. Just cut back about an inch from the back of the thermocouple, there is not much slack. Seperate and strip the wires back about 3/8 inch. Do the same for the new thermocouple. I twisted the wires together and used a solder sleeve to join the wires. The sleeve is just a little plastic tube that has a ring of solder in it that melts with heat gun heat. You can join the wires using butt connectors or whatever method appeals to you. I just wound the extra wire and put a cable tie around it, there is plenty of hiding space in that area. Make sure the new thermocouple is contacting the coil firmly.At this point, for a test, I left everything apart, propped the drawer against the opening and plugged the fridge in. Note that the evaporator fan will not start spinning immediately! It will just sit there making little bumps like it wants to go. The temp in the coil has to get settled before the electronics in the refridge will tell the fan to spin. It takes maybe 20 minutes. Reassemble. Fridge and freezer work great. It does take several hours for all to get cold again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from New Smyrna Beach, FL
- Parts Used:
- WR60X10209
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Socket set, Wrench set
Condenser fan not working. Freezer & frig heating up
Very limited working space in this model. Must remove grill and disconnect elect connector on motor. One additiional tool suggested: Extendable rod with magnet on end because you will most likely drop something. First, remove two screws holding motor to metal strap. Tool must be inserted between blades of fan in order to get to the screws and this is the hard part. Fan and motor are removed as one assy and this takes some manuvering. Might have to remove front screw on metal strap to gain more room. I did not attempt to remove fan shroud. My fan was attached to the motor shaft with a metal clip. Spray a good lubricant such as PB Blaster on the shaft, wait a few minutes and press it or tap it out gently. Save misc parts on old motor for reassembly. Your set up may be different so check out everything before starting.
Was this instruction helpful to you?
Thank you for voting!