GSS23GMKNCES General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- NATHANIEL from PEARLAND, TX
- Parts Used:
- WR60X10258, WR02X11941
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Crusher Motor Striped Want Turn Auger
Unplug refrigerator. Use nutdriver to take two srews out that were holding on the housing. Unplug electric plug and pull out motor and housing. Use hacksaw to cut thru auger holder. Motor will be free to take off,disconnect two wires. Use nutdriver to take out three srews holding motor. Take back cover off and put new motor in cover and reverse procedure. Used new auger wih new motor. Saved big bucks by during this job myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from MANCHESTER, CT
- Parts Used:
- WR55X26671
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
LED light board assembly failed in freezer section
Clear freezer items in the area of repair as light assembly is in the back of the freezer. Suggest removing shelving in the same area to provide more working space. Utliize a small flashlight to provide interior lighting. Use a stubby phillips screwdriver to remove fastener securing the light cover.
Cover snaps out to remove light board assembly. Gently pull to disconnect the electrical connection to the light board. Then pull the light board assembly from the mounting posts securing the light board. Be careful not to snap either posts or the light board.
To install the new light board, I found it easier to connect the electrical source first, then push the light board onto the plastic posts to secure the light board. There are holes in the light board to insure a secure fit. Reinstall the light cover and reinstall the mounting screw. All done in less than 5 minutes!
Cover snaps out to remove light board assembly. Gently pull to disconnect the electrical connection to the light board. Then pull the light board assembly from the mounting posts securing the light board. Be careful not to snap either posts or the light board.
To install the new light board, I found it easier to connect the electrical source first, then push the light board onto the plastic posts to secure the light board. There are holes in the light board to insure a secure fit. Reinstall the light cover and reinstall the mounting screw. All done in less than 5 minutes!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steve from JACKSON, MN
- Parts Used:
- WR02X10782
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
The door stop broke on the sibe by side Fridg
Needed to remove and replace the door stop. It was held on by tow screws that are about 3 inches from the floor. God a hex driver and small ratchet to hold the hex head. unscrewed the old and replaced the new. I did take a picture with my phone and it showed the two screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- stephen from GOODLETTSVLLE, TN
- Parts Used:
- WR23X10783
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
No or little ice would dispense
Went exactly by the video. Perfect job, you send the installation video with the part. You watch the video before or during, goof proof, took longer to disassemble than to replace the part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Purcellville, VA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Fridge evaporator coils frozen
Determined that the defrost heater was bad (didn't test the thermostat or sensor) and attempted to replace it first.
Got the part in one day (super fast shipping).
1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Got the part in one day (super fast shipping).
1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randy from Cypress, TX
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Won't dispence ice or water
Changing out solenoid was very easy, but you don't have to remove trim ring and it didn't fix my problem. Turns out a relay fell out of its holder in the piece you have after removing the 4 screws per the video.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rich from san marcos, CA
- Parts Used:
- WR23X21444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No ice from door, but did have water
I got the wrong switch before so just need to put the right 1 in. Super easy, pop off old, plug in new, click back into place. Done. REALLY REALLY EASY for anyone to do
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Point Pleasant, NJ
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer iced up, no air circulation
Removed the back panel of the freezer to inspect. The coils were totally iced up. Proceeeded to defrost coils with a heat gun. I then removed the defrost element to insepct and meter reading showed as open (infinite resistance). I ordered a replacement element and it arrive 2 days later. Replace the element and everything worked OK except for the ice maker. It seem that moisture had frozen on the motor impeller for the auger drive motor and locked it up. I removed the drive assembly and defrosted the motor impeller to free it. Everthing now is working fine.
Your blow up drawings made this a very easy repair
Thanks
Your blow up drawings made this a very easy repair
Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randall from Sterling Hts, MI
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
unit was not cooling, evaporator was iced over
This is the third time the defrost heater has failed, the part was shipped prompt, and the replacement was upgraded to a dual coil. The repair was quick and more cost effective than having a repair guy come out .
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pap's Sport Shop from Webster Springs, WV
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Defroster unit went out
First let me remind you my husband is disabled so it was up to me to do the repair. I'm 70 yrs old. I first removed everything from freezer and then removed the back cover removimg 4 screws,then i removed the old defrost unit which held 2 screws replaced with the new one then i had to put cover back in place..then put everything back in freezer and so far its working...Only time will tell.But the part was so reasonable that if if i have to i will get another..but not for a while i'm hoping,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harry from DURYEA, PA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Ooltewah, TN
- Parts Used:
- WR51X10101
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator and freezer started loosing its cool
Removed cover exposing defrost heater. Defrosted the cooling system. Removed screws holding defroster, replaced old with new, by way of two quick connect eletrical clips. replaced cover. Pretty easy once I figured our that it was the defroster and not the timer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Olympia, WA
- Parts Used:
- WR55X40445
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
Main computer control board went out.
Fridge and freezer were not keeping proper temp (freezer would get too cold, fridge too warm), as the cooling coils were icing over and needed manual defrosting; it was not going thru the automatic defrost cycle. Changed out the defrost heating element, thermostat, and two temp sensors, none of that worked. It was this part (main board) that was the culprit. Eight wire harnesses to undo and re-hook, one was hard to pull out but it came out. Read and follow the anti-static instructions. To make sure, I grounded my hand with a copper bracelet that was grounded with a copper wire to the metal chassis of the fridge. I also drew out a rough sketch of the connections and numbered them all with a black fine tipped felt marker before undoing them. This finally fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from AUSTIN, TX
- Parts Used:
- WR17X11440
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Water Tank Assembly in the fridge developed a crack at the seam so tank assembly needed to be replaced
I watched the video a couple of times and followed the instructions exactly and the repair was very simple. This repair took me a bit more time than I thought it would just because I followed the steps methodically.
But the video was perfect to guide me through the procedure to replace this part. One of the longest parts was removing the shelving and food storage bins, cleaning them, drying them and then putting them back in after the tank was installed.
But the video was perfect to guide me through the procedure to replace this part. One of the longest parts was removing the shelving and food storage bins, cleaning them, drying them and then putting them back in after the tank was installed.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patrick from Orlando, FL
- Parts Used:
- WR14X47687
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Water not coming out of water dispencer. Not making ice
I thought this was my problem as this part causes 90% of the no water issue. However, replacing this part did not fix my problem. I suggest that you test the valve first by disconnecting the water feed from the filter and running the line into a bucket. Once disconnected press the water on the freezer door and see if water comes out.
Other than that, this part is easy to install. Take off the plastic in front of the filter, remover the retaining screws. Remove lower cover in back of the refrigerator, Remove 1 screw securing the valve, remove cover where tubes enter the refrigerator. Take off tubes from valve (be sure to note what is inlet and outlet) and feed back into refrigerator. Be sure to save the putty when the new one is installed.
Other than that, this part is easy to install. Take off the plastic in front of the filter, remover the retaining screws. Remove lower cover in back of the refrigerator, Remove 1 screw securing the valve, remove cover where tubes enter the refrigerator. Take off tubes from valve (be sure to note what is inlet and outlet) and feed back into refrigerator. Be sure to save the putty when the new one is installed.
Was this instruction helpful to you?
Thank you for voting!